Diana Marcela Cuesta Parra , Felipe Correa Mahecha , Andrés Felipe Rubio Pinzon , Davidcamilo Ramírez Bustos , Leonel Alveyro Teran Llorente , Miguel Fernando Jimenez Jimenez
{"title":"A prototype for on-site generation of chlorinated disinfectant for use in rural aqueducts","authors":"Diana Marcela Cuesta Parra , Felipe Correa Mahecha , Andrés Felipe Rubio Pinzon , Davidcamilo Ramírez Bustos , Leonel Alveyro Teran Llorente , Miguel Fernando Jimenez Jimenez","doi":"10.1016/j.wse.2023.05.005","DOIUrl":null,"url":null,"abstract":"<div><p>Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas. Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 10 L. This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters. Tests were performed using graphite electrodes with areas of 68.4 cm<sup>2</sup> at the laboratory scale and 1 865.0 cm<sup>2</sup> at the prototype scale. A design for experiments with different operating times, chloride concentrations, and electric current intensities was developed. The optimal operating time, sodium chloride concentration, and current intensity at the laboratory scale were 120 min, 150 g of chloride per liter, and 3 A, respectively, leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl<sub>2</sub> per kilojoule. At the prototype scale, the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min, a sodium chloride concentration of 100 g of chloride per liter, and a current intensity of 70 A, reaching an energy efficiency of 42.56 mg of Cl<sub>2</sub> per kilojoule. In addition, this study evaluated the influences of the chloride concentration, current intensity, and operating time on the production of sodium hypochlorite at the two scales, and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems. The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.</p></div>","PeriodicalId":23628,"journal":{"name":"Water science and engineering","volume":"17 1","pages":"Pages 33-40"},"PeriodicalIF":3.7000,"publicationDate":"2023-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1674237023000601/pdfft?md5=f6e56a2ca6c201ca2e1734f88c31273e&pid=1-s2.0-S1674237023000601-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water science and engineering","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1674237023000601","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0
Abstract
Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas. Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 10 L. This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters. Tests were performed using graphite electrodes with areas of 68.4 cm2 at the laboratory scale and 1 865.0 cm2 at the prototype scale. A design for experiments with different operating times, chloride concentrations, and electric current intensities was developed. The optimal operating time, sodium chloride concentration, and current intensity at the laboratory scale were 120 min, 150 g of chloride per liter, and 3 A, respectively, leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl2 per kilojoule. At the prototype scale, the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min, a sodium chloride concentration of 100 g of chloride per liter, and a current intensity of 70 A, reaching an energy efficiency of 42.56 mg of Cl2 per kilojoule. In addition, this study evaluated the influences of the chloride concentration, current intensity, and operating time on the production of sodium hypochlorite at the two scales, and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems. The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.
期刊介绍:
Water Science and Engineering journal is an international, peer-reviewed research publication covering new concepts, theories, methods, and techniques related to water issues. The journal aims to publish research that helps advance the theoretical and practical understanding of water resources, aquatic environment, aquatic ecology, and water engineering, with emphases placed on the innovation and applicability of science and technology in large-scale hydropower project construction, large river and lake regulation, inter-basin water transfer, hydroelectric energy development, ecological restoration, the development of new materials, and sustainable utilization of water resources.