{"title":"Valuing the use of GeneXpert test as an unconventional approach to diagnose pulmonary tuberculosis","authors":"Amany Omar, A. Elfadl, Y. Ahmed, M. Hosny","doi":"10.4103/ejb.ejb_88_18","DOIUrl":null,"url":null,"abstract":"Background A rapid, highly sensitive, and qualitative diagnostic test will significantly reduce the incidence of tuberculosis (TB). GeneXpert test is the test that is supposed to play this role with those specifications. Objective Our goal was to assess the precision of the GeneXpert test in the diagnosis of pulmonary TB. Patients and methods This cross-sectional analytic study was carried out at Assiut University Hospital in collaboration with Assiut Chest Hospital, Assiut, Egypt. A total of 67 patients of suspected pulmonary TB were included. For microbiological examination, two sputum samples were obtained from each patient within the same day. One sample was collected at Assiut University Hospital and subjected to smear microscopy by Ziehl–Neelsen staining and culture on Lowenstein–Jensen media. The other sample was taken at Assiut Chest Hospital to be processed for GeneXpert Mycobacterium tuberculosis/rifampicin assay. The culture was applied as a confirmatory test to evaluate the Xpert Mycobacterium tuberculosis/rifampicin assay test. Results GeneXpert had 95.9% sensitivity and 94.4% specificity in diagnosing pulmonary TB with the area under the curve of 0.95 and overall diagnostic accuracy of 95.5%. Ziehl–Neelsen examination had 65.3% sensitivity and 100% specificity with the area under the curve of 0.83 and overall diagnostic accuracy of 74.6. For smear-negative, culture-positive cases, GeneXpert showed sensitivity of 94.1%. False-positive GeneXpert for TB was recorded in just one patient. Conclusion The GeneXpert test is accurate in diagnosing pulmonary TB and its greatest benefit is clearly demonstrated in smear-negative TB cases. However, the test is not free from some fallacies, even if they are a few, which draws our attention to the importance of the conventional culture for TB and the clinical correlation.","PeriodicalId":34128,"journal":{"name":"Egyptian Journal of Bronchology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Bronchology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ejb.ejb_88_18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 4

Abstract

Background A rapid, highly sensitive, and qualitative diagnostic test will significantly reduce the incidence of tuberculosis (TB). GeneXpert test is the test that is supposed to play this role with those specifications. Objective Our goal was to assess the precision of the GeneXpert test in the diagnosis of pulmonary TB. Patients and methods This cross-sectional analytic study was carried out at Assiut University Hospital in collaboration with Assiut Chest Hospital, Assiut, Egypt. A total of 67 patients of suspected pulmonary TB were included. For microbiological examination, two sputum samples were obtained from each patient within the same day. One sample was collected at Assiut University Hospital and subjected to smear microscopy by Ziehl–Neelsen staining and culture on Lowenstein–Jensen media. The other sample was taken at Assiut Chest Hospital to be processed for GeneXpert Mycobacterium tuberculosis/rifampicin assay. The culture was applied as a confirmatory test to evaluate the Xpert Mycobacterium tuberculosis/rifampicin assay test. Results GeneXpert had 95.9% sensitivity and 94.4% specificity in diagnosing pulmonary TB with the area under the curve of 0.95 and overall diagnostic accuracy of 95.5%. Ziehl–Neelsen examination had 65.3% sensitivity and 100% specificity with the area under the curve of 0.83 and overall diagnostic accuracy of 74.6. For smear-negative, culture-positive cases, GeneXpert showed sensitivity of 94.1%. False-positive GeneXpert for TB was recorded in just one patient. Conclusion The GeneXpert test is accurate in diagnosing pulmonary TB and its greatest benefit is clearly demonstrated in smear-negative TB cases. However, the test is not free from some fallacies, even if they are a few, which draws our attention to the importance of the conventional culture for TB and the clinical correlation.
评价GeneXpert检测作为一种非传统方法诊断肺结核的价值
背景快速、高灵敏度和定性的诊断测试将显著降低结核病的发病率。GeneXpert测试就是应该在这些规范中扮演这个角色的测试。目的评估GeneXpert试验在肺结核诊断中的准确性。患者和方法这项横断面分析研究是在阿西乌大学医院与埃及阿西乌胸科医院合作进行的。共有67名疑似肺结核患者被纳入研究。为了进行微生物检查,在同一天内从每位患者身上采集两份痰液样本。一个样本在阿西尤特大学医院采集,并通过Ziehl–Neelsen染色进行涂片显微镜检查,并在Lowenstein–Jensen培养基上培养。另一份样本在Assiut胸科医院采集,用于GeneXpert结核分枝杆菌/利福平检测。该培养物被用作验证性测试,以评估Xpert结核分枝杆菌/利福平测定测试。结果GeneXpert对肺结核的诊断灵敏度为95.9%,特异性为94.4%,曲线下面积为0.95,总诊断准确率为95.5%;Ziehl–Neelsen检查对肺结核诊断灵敏度为65.3%,特异度为100%,曲线下区域为0.83,总诊断正确率为74.6。对于涂片阴性、培养阳性的病例,GeneXpert显示出94.1%的敏感性。只有一名患者的结核病假阳性记录。结论GeneXpert试验对肺结核的诊断是准确的,其最大益处在涂阴结核病例中得到明确证明。然而,该测试并非没有一些谬误,即使它们是少数,这引起了我们对传统文化对结核病的重要性及其临床相关性的关注。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Egyptian Journal of Bronchology
Egyptian Journal of Bronchology RESPIRATORY SYSTEM-
自引率
7.70%
发文量
56
审稿时长
9 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信