{"title":"Hypoglycemia avoidance behaviour in active Qatari adults with type 1 diabetes under blood glucose monitoring device","authors":"Georges Jabbour,&nbsp;Souhail Hermassi","doi":"10.1016/j.deman.2023.100176","DOIUrl":null,"url":null,"abstract":"<div><h3>Aims</h3><p>The present study aimed to explore the relationship between fear of hypoglycemia and exercise management strategies in active Qatari adults with T1D during the COVID-19 pandemic, and to explore the potential role of continuous glucose monitoring (CGM) devices in promoting safe physical activity practices.</p></div><div><h3>Methods</h3><p>Participants completed the Hypoglycemia Fear Survey (HFS) questionnaire and the International Physical Activity Questionnaire (IPAQ). Out of the 102 participants, 41 were considered \"active\" and under CGM and were included in the analysis.</p></div><div><h3>Results</h3><p>Multiple linear regression analysis revealed a significant positive correlation between the behavior dimension of the HFS scores and both vigorous physical activity and MET-minutes per week (<em>R</em><sup>2</sup> adj. = 0.055; β = 0.56; <em>p</em> = 0.05 and <em>R</em><sup>2</sup> adj. = 0.039; β = 0.38; <em>p</em> = 0.04). The results showed a significant positive association between HbA1c levels and the behavior dimension of the HFS (<em>R</em> = 0.39, <em>p</em> = 0.005), as well as between the number of episodes of severe hypoglycemia and the behavior dimension (<em>R</em> = 0.46, <em>p</em> = 0.042).</p></div><div><h3>Conclusion</h3><p>These findings highlight the need for effective strategies to manage fear of hypoglycemia and promote physical activity in individuals with T1D. The use of CGM devices may provide added safety to physical activity practices by reducing the risk of hypoglycemia.</p></div>","PeriodicalId":72796,"journal":{"name":"Diabetes epidemiology and management","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes epidemiology and management","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666970623000550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Aims

The present study aimed to explore the relationship between fear of hypoglycemia and exercise management strategies in active Qatari adults with T1D during the COVID-19 pandemic, and to explore the potential role of continuous glucose monitoring (CGM) devices in promoting safe physical activity practices.

Methods

Participants completed the Hypoglycemia Fear Survey (HFS) questionnaire and the International Physical Activity Questionnaire (IPAQ). Out of the 102 participants, 41 were considered "active" and under CGM and were included in the analysis.

Results

Multiple linear regression analysis revealed a significant positive correlation between the behavior dimension of the HFS scores and both vigorous physical activity and MET-minutes per week (R2 adj. = 0.055; β = 0.56; p = 0.05 and R2 adj. = 0.039; β = 0.38; p = 0.04). The results showed a significant positive association between HbA1c levels and the behavior dimension of the HFS (R = 0.39, p = 0.005), as well as between the number of episodes of severe hypoglycemia and the behavior dimension (R = 0.46, p = 0.042).

Conclusion

These findings highlight the need for effective strategies to manage fear of hypoglycemia and promote physical activity in individuals with T1D. The use of CGM devices may provide added safety to physical activity practices by reducing the risk of hypoglycemia.

血糖监测设备下卡塔尔1型糖尿病活动成年人的低血糖回避行为
目的本研究旨在探讨新冠肺炎大流行期间卡塔尔活跃的T1D成年人对低血糖的恐惧与运动管理策略之间的关系,并探讨连续血糖监测(CGM)设备在促进安全体育活动实践中的潜在作用。方法参与者完成低血糖恐惧问卷(HFS)和国际体育活动问卷(IPAQ)。在102名参与者中,有41人被认为是“活跃的”,处于CGM之下,并被纳入分析。结果多元线性回归分析显示,HFS评分的行为维度与剧烈体力活动和每周MET分钟数呈正相关(R2 adj.=0.055;β=0.56;p=0.05;R2 adj.=0.039;β=0.38;p=0.04)HFS(R=0.39,p=0.005),以及严重低血糖发作次数与行为维度之间(R=0.46,p=0.042)。CGM装置的使用可以通过降低低血糖的风险来为体育活动实践提供额外的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Diabetes epidemiology and management
Diabetes epidemiology and management Endocrinology, Diabetes and Metabolism, Public Health and Health Policy
CiteScore
1.10
自引率
0.00%
发文量
0
审稿时长
14 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信