Evaluation of metallic stents for malignant ureteral obstruction- a single institution experience

Gupta A
{"title":"Evaluation of metallic stents for malignant ureteral obstruction- a single institution experience","authors":"Gupta A","doi":"10.33552/aun.2020.02.000539","DOIUrl":null,"url":null,"abstract":"This work is licensed under Creative Commons Attribution 4.0 License AUN.MS.ID.000539. Abstract Introduction: Ureteral obstruction caused by extrinsic compression is commonly associated with intra-abdominal malignancy. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. The limitation of polymeric ureteral stents in patients is that they get easily compressed and recurrence of obstruction is seen very quickly. The metallic stents were introduced to improve the patency rates of patients with chronic upper urinary tract obstruction, obviating the need for frequent stent exchanges. We report our clinical experiences with the use of metallic ureteral stents in the management of poor ureteral drainage due to extrinsic malignant obstruction/compression. Materials and methods: In this study, we described the functional outcomes of a Resonance metallic ureteral stent in patients with malignant ureteral obstruction done during August 2016 till August 2018. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional duration of each stent was calculated. Results: A total of 27 stents were successfully inserted in 20 patients with malignant ureteral obstruction. After insertion of metallic stents, hydronephrosis subsided or remained stable in 89% of the ureteral units. Serum creatinine decreased or remained stable in 90% of these patients. In 15% ureteric units metallic stents were required to be removed or changed .The Resonance stent exhibited a mean increase in functional response at minimal 1year follow up. Conclusion: Our results indicate that metallic ureteral stent placement is a technically feasible procedure with minimal complications, increased longevity and is well tolerated among patients.","PeriodicalId":93263,"journal":{"name":"Annals of urology & nephrology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of urology & nephrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33552/aun.2020.02.000539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work is licensed under Creative Commons Attribution 4.0 License AUN.MS.ID.000539. Abstract Introduction: Ureteral obstruction caused by extrinsic compression is commonly associated with intra-abdominal malignancy. Internal drainage with ureteral stents is typically the first-line therapy to relieve such obstructions. The limitation of polymeric ureteral stents in patients is that they get easily compressed and recurrence of obstruction is seen very quickly. The metallic stents were introduced to improve the patency rates of patients with chronic upper urinary tract obstruction, obviating the need for frequent stent exchanges. We report our clinical experiences with the use of metallic ureteral stents in the management of poor ureteral drainage due to extrinsic malignant obstruction/compression. Materials and methods: In this study, we described the functional outcomes of a Resonance metallic ureteral stent in patients with malignant ureteral obstruction done during August 2016 till August 2018. Stent failure was detected by clinical symptoms, imaging studies, and renal function tests. The functional duration of each stent was calculated. Results: A total of 27 stents were successfully inserted in 20 patients with malignant ureteral obstruction. After insertion of metallic stents, hydronephrosis subsided or remained stable in 89% of the ureteral units. Serum creatinine decreased or remained stable in 90% of these patients. In 15% ureteric units metallic stents were required to be removed or changed .The Resonance stent exhibited a mean increase in functional response at minimal 1year follow up. Conclusion: Our results indicate that metallic ureteral stent placement is a technically feasible procedure with minimal complications, increased longevity and is well tolerated among patients.
金属支架治疗恶性输尿管梗阻的评价-单一机构经验
本作品在知识共享署名4.0许可下授权,授权编号:ms . id .000539。摘要简介:外源性压迫引起的输尿管梗阻通常与腹内恶性肿瘤有关。输尿管支架内引流通常是缓解此类阻塞的一线治疗方法。聚合物输尿管支架在患者中的局限性是它们很容易被压缩,并且很快就会发现梗阻复发。金属支架的引入是为了提高慢性上尿路梗阻患者的通畅率,避免频繁更换支架。我们报告使用金属输尿管支架治疗因外源性恶性阻塞/压迫导致输尿管引流不良的临床经验。材料和方法:在本研究中,我们描述了共振金属输尿管支架在2016年8月至2018年8月期间用于恶性输尿管梗阻患者的功能结果。通过临床症状、影像学检查和肾功能检查来检测支架失效。计算每个支架的功能持续时间。结果:20例恶性输尿管梗阻患者共成功置入支架27枚。植入金属支架后,89%的输尿管单位肾积水消退或保持稳定。90%的患者血清肌酐下降或保持稳定。在15%的输尿管单元中,金属支架需要移除或更换。在至少1年的随访中,共振支架的功能反应平均增加。结论:我们的研究结果表明金属输尿管支架置入术是一种技术上可行的手术,并发症少,延长寿命,患者耐受性好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信