S. Kanjanauthai, K. Bhasin, L. Pirelli, C. Kliger, N. Lung
{"title":"Conduction Abnormalities After Transcatheter Aortic Valve Replacement","authors":"S. Kanjanauthai, K. Bhasin, L. Pirelli, C. Kliger, N. Lung","doi":"10.14520/USC.2018.7.2","DOIUrl":null,"url":null,"abstract":"Transcatheter aortic valve replacement (TAVR) has been established as a therapeutic option for patients with severe symptomatic aortic stenosis who are of intermediate or higher surgical risk. Several periprocedural complications are reduced with newer transcatheter heart valve generations; however, conduction abnormalities and the need for permanent pacemaker implantation have remained unchanged and are the most frequent TAVR complications. The close relationship of the atrioventricular node and left bundle branch to the subaortic region explains these potential conduction abnormalities. This article highlights conduction abnormalities after TAVR with a focus on basic conduction system anatomy in relation to the aortic valve, the mechanism, incidence, predisposing factors for occurrence, impact on mortality and finally, proposed treatment algorithms for management.","PeriodicalId":37809,"journal":{"name":"US Cardiology Review","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"US Cardiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14520/USC.2018.7.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2
Abstract
Transcatheter aortic valve replacement (TAVR) has been established as a therapeutic option for patients with severe symptomatic aortic stenosis who are of intermediate or higher surgical risk. Several periprocedural complications are reduced with newer transcatheter heart valve generations; however, conduction abnormalities and the need for permanent pacemaker implantation have remained unchanged and are the most frequent TAVR complications. The close relationship of the atrioventricular node and left bundle branch to the subaortic region explains these potential conduction abnormalities. This article highlights conduction abnormalities after TAVR with a focus on basic conduction system anatomy in relation to the aortic valve, the mechanism, incidence, predisposing factors for occurrence, impact on mortality and finally, proposed treatment algorithms for management.
期刊介绍:
US Cardiology Review (USC) is an international, US-English language, peer-reviewed journal that is published bi-annually and aims to assist time-pressured physicians to stay abreast of key advances and opinion in the area of cardiovascular disease. The journal comprises balanced and comprehensive review articles written by leading authorities. The journal provides updates on a range of salient issues to support physicians in developing their knowledge and effectiveness in day-to-day clinical practice. The journal endeavours to support the continuous medical education of specialist and general cardiologists and disseminate knowledge of the field to the wider cardiovascular community.