A baseline estimation procedure to improve MDA evaluation in gamma-ray spectrometry

IF 2.8 3区 物理与天体物理 Q2 PHYSICS, MULTIDISCIPLINARY
Elio Tomarchio, Mariarosa Giardina, Pietro Buffa
{"title":"A baseline estimation procedure to improve MDA evaluation in gamma-ray spectrometry","authors":"Elio Tomarchio,&nbsp;Mariarosa Giardina,&nbsp;Pietro Buffa","doi":"10.1140/epjp/s13360-023-04308-3","DOIUrl":null,"url":null,"abstract":"<div><p>The evaluation of minimum detectable activity (MDA) for a radionuclide in a gamma-ray spectrum is generally carried out through the computation of a suitable background count. This task is sometimes difficult for complex spectra for the presence of many photopeaks which make the trend of continuum extremely variable due to multiple dispersion effects and interference factors. It follows that the MDA assessment must be take into account the contributions of all gamma emissions of radionuclides contained in a sample and its value can be significantly higher than that determined by considering only the background of the spectrometric system due to the overlapping of other peaks. A procedure or an algorithm to determine, each time, the count values to be used for the calculation of MDA is interesting and useful. In this work, some of the more recent algorithms proposed for background subtraction in a gamma-ray spectrum have been examined, applying them in an inverse way for the evaluation of baseline trend in the whole energy range. Among the algorithms examined, particular attention was paid to the application of SNIP (statistical sensitive nonlinear iterative peak clipping) algorithms, which are the simplest to adopt and implement in an application procedure. The results obtained in the analysis of test gamma-ray spectra are satisfactory and allow to quickly determine the MDA values with a formulation based on the ISO-11929 standard.</p></div>","PeriodicalId":792,"journal":{"name":"The European Physical Journal Plus","volume":"138 8","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2023-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1140/epjp/s13360-023-04308-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European Physical Journal Plus","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1140/epjp/s13360-023-04308-3","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The evaluation of minimum detectable activity (MDA) for a radionuclide in a gamma-ray spectrum is generally carried out through the computation of a suitable background count. This task is sometimes difficult for complex spectra for the presence of many photopeaks which make the trend of continuum extremely variable due to multiple dispersion effects and interference factors. It follows that the MDA assessment must be take into account the contributions of all gamma emissions of radionuclides contained in a sample and its value can be significantly higher than that determined by considering only the background of the spectrometric system due to the overlapping of other peaks. A procedure or an algorithm to determine, each time, the count values to be used for the calculation of MDA is interesting and useful. In this work, some of the more recent algorithms proposed for background subtraction in a gamma-ray spectrum have been examined, applying them in an inverse way for the evaluation of baseline trend in the whole energy range. Among the algorithms examined, particular attention was paid to the application of SNIP (statistical sensitive nonlinear iterative peak clipping) algorithms, which are the simplest to adopt and implement in an application procedure. The results obtained in the analysis of test gamma-ray spectra are satisfactory and allow to quickly determine the MDA values with a formulation based on the ISO-11929 standard.

提高伽玛射线能谱中MDA评价的基线估计程序
对伽玛射线谱中放射性核素的最低可探测活性(MDA)的评估通常是通过计算适当的本底计数来进行的。对于复杂光谱,由于存在许多光峰,由于多重色散效应和干扰因素,使得连续谱的趋势变化很大,因此这项任务有时很困难。由此可见,MDA的评估必须考虑到样品中所含放射性核素的所有γ辐射的贡献,其值可以明显高于仅考虑光谱系统的背景所确定的值,因为其他峰的重叠。每次确定用于计算MDA的计数值的过程或算法是有趣且有用的。在这项工作中,研究了一些最近提出的用于伽马射线谱背景减法的算法,并将它们以相反的方式应用于整个能量范围内基线趋势的评估。在研究的算法中,特别关注了SNIP(统计敏感非线性迭代峰值裁剪)算法的应用,该算法在应用程序中最容易采用和实现。在测试伽马射线谱分析中获得的结果令人满意,并且可以根据ISO-11929标准快速确定MDA值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The European Physical Journal Plus
The European Physical Journal Plus PHYSICS, MULTIDISCIPLINARY-
CiteScore
5.40
自引率
8.80%
发文量
1150
审稿时长
4-8 weeks
期刊介绍: The aims of this peer-reviewed online journal are to distribute and archive all relevant material required to document, assess, validate and reconstruct in detail the body of knowledge in the physical and related sciences. The scope of EPJ Plus encompasses a broad landscape of fields and disciplines in the physical and related sciences - such as covered by the topical EPJ journals and with the explicit addition of geophysics, astrophysics, general relativity and cosmology, mathematical and quantum physics, classical and fluid mechanics, accelerator and medical physics, as well as physics techniques applied to any other topics, including energy, environment and cultural heritage.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信