Changes in ambulatory glucose profile in people with type 1 diabetes using an automated insulin delivery system - two year follow-up retrospective analysis of real-world data
Michael Müller-Korbsch , Antonia Kietaibl , Yves Haufe , Peter Fasching
{"title":"Changes in ambulatory glucose profile in people with type 1 diabetes using an automated insulin delivery system - two year follow-up retrospective analysis of real-world data","authors":"Michael Müller-Korbsch , Antonia Kietaibl , Yves Haufe , Peter Fasching","doi":"10.1016/j.deman.2023.100150","DOIUrl":null,"url":null,"abstract":"<div><p>The number of available automated insulin delivery (AID) systems is increasing in Austria and people with diabetes (PwD) replace sensor-augmented pump (SAP) therapy more and more frequently. The present study is the two years follow-up of our prior monocentric, retrospective analysis conducted between 2019 and 2021, comparing SAP and open-source AID systems in people with type 1 diabetes. This second-year analysis included 25 PwD and investigated glycemic changes based on ambulatory glucose profiles (AGP). In comparison to the first year, a worsening of mean glucose (125.4 to 135.2 mg/dl, <em>P</em> = 0.038), time in range ((TIR), 84.2 to 77.0%, <em>P</em> = 0.012), time above range ((TAR), 11.6% to 18.5%, <em>P</em> = 0.017) and glycemia risk index ((GRI), 24.8 to 35.0%, <em>P</em> = 0.026) was observed. The reduction of mean glucose and glucose variability with AID in the first year was due to a significant decrease in time in hyperglycemia with resulting higher TIR and lower GRI. In this second-year follow up, TIR and GRI showed a significant deterioration, a familiar phenomenon in diabetology. However, open-source AID systems showed continuous safety, as there was no increase in time below range (TBR) even after two years. Despite the slight deterioration in the glycemic parameters, open-source AID systems were able to demonstrate sufficient glycemic control according to international consensus guidelines while offering the characteristic benefits of a reduced burden of diabetes management. A descriptive comparison of different AID algorithms indicated an improved glycemic control with more advanced features such as basal rate modification, auto bolus function and autotuning.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666970623000227","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The number of available automated insulin delivery (AID) systems is increasing in Austria and people with diabetes (PwD) replace sensor-augmented pump (SAP) therapy more and more frequently. The present study is the two years follow-up of our prior monocentric, retrospective analysis conducted between 2019 and 2021, comparing SAP and open-source AID systems in people with type 1 diabetes. This second-year analysis included 25 PwD and investigated glycemic changes based on ambulatory glucose profiles (AGP). In comparison to the first year, a worsening of mean glucose (125.4 to 135.2 mg/dl, P = 0.038), time in range ((TIR), 84.2 to 77.0%, P = 0.012), time above range ((TAR), 11.6% to 18.5%, P = 0.017) and glycemia risk index ((GRI), 24.8 to 35.0%, P = 0.026) was observed. The reduction of mean glucose and glucose variability with AID in the first year was due to a significant decrease in time in hyperglycemia with resulting higher TIR and lower GRI. In this second-year follow up, TIR and GRI showed a significant deterioration, a familiar phenomenon in diabetology. However, open-source AID systems showed continuous safety, as there was no increase in time below range (TBR) even after two years. Despite the slight deterioration in the glycemic parameters, open-source AID systems were able to demonstrate sufficient glycemic control according to international consensus guidelines while offering the characteristic benefits of a reduced burden of diabetes management. A descriptive comparison of different AID algorithms indicated an improved glycemic control with more advanced features such as basal rate modification, auto bolus function and autotuning.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.