{"title":"The Efficacy of Miniaturized Repetitive Transcranial Magnetic Stimulation in Patients with Depression","authors":"Sangmin Lee, K. Jang, S. Yoon, J. Chae","doi":"10.9758/cpn.2019.17.3.409","DOIUrl":null,"url":null,"abstract":"Objective The present study aimed to evaluate the efficacy of repetitive transcranial magnetic stimulation (rTMS) at a high frequency using a miniaturized device compared to standard rTMS and sham rTMS for the treatment of depression. Methods Fifty-four patients with depression were randomly assigned to either 15 days of miniaturized, standard, or sham rTMS. The stimulation consisted of 60 trains of 5 seconds at 10 Hz for 30 minutes. Clinical measures were assessed at baseline and on the final day of the stimulation. Results A repeated-measures analysis of variance revealed a significant main effect of time and a time by group interaction on Hamilton Rating Scale for Depression scores. There were no significant correlations between individual motor thresholds and changes of clinical outcomes. Our results revealed a significant reduction in the Hamilton Rating Scale for Depression in the miniaturized and standard groups compared to the sham group. Conclusion The antidepressant utility of miniaturized rTMS using subthreshold stimulation was comparable to that of standard stimulation.","PeriodicalId":10420,"journal":{"name":"Clinical Psychopharmacology and Neuroscience","volume":"17 1","pages":"409 - 414"},"PeriodicalIF":2.4000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Psychopharmacology and Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.9758/cpn.2019.17.3.409","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 12
Abstract
Objective The present study aimed to evaluate the efficacy of repetitive transcranial magnetic stimulation (rTMS) at a high frequency using a miniaturized device compared to standard rTMS and sham rTMS for the treatment of depression. Methods Fifty-four patients with depression were randomly assigned to either 15 days of miniaturized, standard, or sham rTMS. The stimulation consisted of 60 trains of 5 seconds at 10 Hz for 30 minutes. Clinical measures were assessed at baseline and on the final day of the stimulation. Results A repeated-measures analysis of variance revealed a significant main effect of time and a time by group interaction on Hamilton Rating Scale for Depression scores. There were no significant correlations between individual motor thresholds and changes of clinical outcomes. Our results revealed a significant reduction in the Hamilton Rating Scale for Depression in the miniaturized and standard groups compared to the sham group. Conclusion The antidepressant utility of miniaturized rTMS using subthreshold stimulation was comparable to that of standard stimulation.
期刊介绍:
Clinical Psychopharmacology and Neuroscience (Clin Psychopharmacol Neurosci) launched in 2003, is the official journal of The Korean College of Neuropsychopharmacology (KCNP), and the associate journal for Asian College of Neuropsychopharmacology (AsCNP). This journal aims to publish evidence-based, scientifically written articles related to clinical and preclinical studies in the field of psychopharmacology and neuroscience. This journal intends to foster and encourage communications between psychiatrist, neuroscientist and all related experts in Asia as well as worldwide. It is published four times a year at the last day of February, May, August, and November.