Hengyi Yu, Xiuhua Ren, Lu Liu, Dong Xiang, Xiping Li, Juan Li, Dong Liu, X. Gong
{"title":"Simultaneous determination of eight antiepileptic drugs and two metabolites in human plasma by liquid chromatography/tandem mass spectrometry","authors":"Hengyi Yu, Xiuhua Ren, Lu Liu, Dong Xiang, Xiping Li, Juan Li, Dong Liu, X. Gong","doi":"10.1556/1326.2022.01024","DOIUrl":null,"url":null,"abstract":"\n Epilepsy is one of the most prevalent neurological conditions and antiepileptic drugs are the mainstay of epilepsy treatment. High variation in pharmacokinetic profiles of several antiepileptic drugs highlights the importance of therapeutic drug monitoring to estimate pharmacokinetic properties and consequently individualize drug posology. In this work, a simple, rapid and robust liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of carbamazepine and its metabolite carbamazepine-10,11-epoxide, gabapentin, levetiracetam, lamotrigine, oxcarbazepine and its metabolite mono-hydroxy-derivative metabolite, phenytoin, topiramate, and valproic acid in human plasma for therapeutic drug monitoring. d\n \n 6\n -Levetiracetam, d\n \n 4\n -gabapentin and d\n \n 6\n -valproic acid were used as internal standards. After addition of internal standards along with two-step protein precipitation and dilution sample preparation, plasma samples were analyzed on a C18 column using a gradient elution in 5 min without interference. The calibration curves were linear over a 100-fold concentration range, with determination coefficients (r\n \n 2\n ) greater than 0.99 for all analytes. The limit of quantification was 0.5 μg mL−1 (0.1 μg mL−1 for oxcarbazepine, 2 μg mL−1 for levetiracetam, and 10 μg mL−1 for valproic acid) with precision and accuracy ranging from 3% to 9% and from 94% to 112%, respectively. Intra- and inter-day precision and accuracy values were within 15% at low, medium and high quality control levels. No significant matrix effect was observed in the normal, hemolyzed, lipemic, and hyperbilirubin blood samples. This method was successfully used in the identification and quantitation of antiepileptic drugs in patients undergoing mono- or polytherapy for epilepsy.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01024","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1
Abstract
Epilepsy is one of the most prevalent neurological conditions and antiepileptic drugs are the mainstay of epilepsy treatment. High variation in pharmacokinetic profiles of several antiepileptic drugs highlights the importance of therapeutic drug monitoring to estimate pharmacokinetic properties and consequently individualize drug posology. In this work, a simple, rapid and robust liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of carbamazepine and its metabolite carbamazepine-10,11-epoxide, gabapentin, levetiracetam, lamotrigine, oxcarbazepine and its metabolite mono-hydroxy-derivative metabolite, phenytoin, topiramate, and valproic acid in human plasma for therapeutic drug monitoring. d
6
-Levetiracetam, d
4
-gabapentin and d
6
-valproic acid were used as internal standards. After addition of internal standards along with two-step protein precipitation and dilution sample preparation, plasma samples were analyzed on a C18 column using a gradient elution in 5 min without interference. The calibration curves were linear over a 100-fold concentration range, with determination coefficients (r
2
) greater than 0.99 for all analytes. The limit of quantification was 0.5 μg mL−1 (0.1 μg mL−1 for oxcarbazepine, 2 μg mL−1 for levetiracetam, and 10 μg mL−1 for valproic acid) with precision and accuracy ranging from 3% to 9% and from 94% to 112%, respectively. Intra- and inter-day precision and accuracy values were within 15% at low, medium and high quality control levels. No significant matrix effect was observed in the normal, hemolyzed, lipemic, and hyperbilirubin blood samples. This method was successfully used in the identification and quantitation of antiepileptic drugs in patients undergoing mono- or polytherapy for epilepsy.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.