The positive association between various demographic characteristics and peak expiratory flow in employees of Zanjan university of medical sciences

IF 1.1 Q4 IMMUNOLOGY
Samad Ghodrati, Jafar Kiasatfar, N. Parsamanesh, Shohre Alian Samakkhah, M. Asadi-Khiavi, A. Pezeshgi
{"title":"The positive association between various demographic characteristics and peak expiratory flow in employees of Zanjan university of medical sciences","authors":"Samad Ghodrati, Jafar Kiasatfar, N. Parsamanesh, Shohre Alian Samakkhah, M. Asadi-Khiavi, A. Pezeshgi","doi":"10.34172/ipp.2022.33402","DOIUrl":null,"url":null,"abstract":"Introduction: Peak expiratory flow (PEF) is a reliable criterion for assessing respiratory capacity, and has a wide range of clinical application as a marker of asthma control. However, its wide variability undermines its efficacy. Objectives: This study was designed to evaluate PEF changes in staff of Zanjan University of Medical Sciences. Patients and Methods: Four hundred employees of this university participated in this cross-sectional study. Their PEF values were measured using peak flow meter in the morning at 8 AM and in the afternoon at 2 PM by three times for each individual, and then the highest amount of PEF was recorded about for measurement. Results: Obviously, PEF values were higher in the afternoon (43865 L/min) in comparison to the morning measurements (404.60 L/min) by paired t test (P<0.001). In addition, mean of PEF in the males was higher than the females in the morning (469.77 L/min, versus 355.94 L/min; independent t test, P<0.001), and also PEF mean of the morning and afternoon was higher in the males than females (404.6 L/min, versus 338.65 L/min, independent t test, P<0.001). Additionally, the variability level in the males and females was 8.39±6 and 8.47±4 L/min, respectively. There was a high correlation between the level of PEF variability and height (5.1). Meanwhile, a moderate correlation between PEF level and body mass index (BMI) was detected (1.47). There was not any correlation between the level of PEF and age. Conclusion: Based on our findings, PEF inter-individual variability depends on age, gender height, and BMI however, it is worthwhile that this PEF inter-individual variability to be measured just until 4 PM. All these variables were obtained under the range of 20%; however, relying on references, the variability of 20% is considered as normal.","PeriodicalId":13454,"journal":{"name":"Immunopathologia Persa","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Immunopathologia Persa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ipp.2022.33402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Peak expiratory flow (PEF) is a reliable criterion for assessing respiratory capacity, and has a wide range of clinical application as a marker of asthma control. However, its wide variability undermines its efficacy. Objectives: This study was designed to evaluate PEF changes in staff of Zanjan University of Medical Sciences. Patients and Methods: Four hundred employees of this university participated in this cross-sectional study. Their PEF values were measured using peak flow meter in the morning at 8 AM and in the afternoon at 2 PM by three times for each individual, and then the highest amount of PEF was recorded about for measurement. Results: Obviously, PEF values were higher in the afternoon (43865 L/min) in comparison to the morning measurements (404.60 L/min) by paired t test (P<0.001). In addition, mean of PEF in the males was higher than the females in the morning (469.77 L/min, versus 355.94 L/min; independent t test, P<0.001), and also PEF mean of the morning and afternoon was higher in the males than females (404.6 L/min, versus 338.65 L/min, independent t test, P<0.001). Additionally, the variability level in the males and females was 8.39±6 and 8.47±4 L/min, respectively. There was a high correlation between the level of PEF variability and height (5.1). Meanwhile, a moderate correlation between PEF level and body mass index (BMI) was detected (1.47). There was not any correlation between the level of PEF and age. Conclusion: Based on our findings, PEF inter-individual variability depends on age, gender height, and BMI however, it is worthwhile that this PEF inter-individual variability to be measured just until 4 PM. All these variables were obtained under the range of 20%; however, relying on references, the variability of 20% is considered as normal.
赞詹医科大学员工不同人口学特征与呼气峰流量呈正相关
引言:呼气峰流量(PEF)是评估呼吸能力的可靠标准,作为哮喘控制的标志物,具有广泛的临床应用。然而,其广泛的可变性破坏了其功效。目的:本研究旨在评估赞詹医科大学工作人员的PEF变化。患者和方法:该大学的400名员工参与了这项横断面研究。他们的PEF值在早上8点和下午2点使用峰值流量计对每个个体测量三次,然后记录最高的PEF量以进行测量。结果:通过配对t检验,下午的PEF值(43865L/min)明显高于上午的测量值(404.60L/min)(P<0.001)。此外,男性的PEF平均值高于女性(469.77L/min,355.94L/min;独立t检验,P<0.001),上午和下午的PEF平均值男性高于女性(404.6L/min,而338.65L/min,独立t检验,P<0.001)。此外,男性和女性的变异水平分别为8.39±6和8.47±4L/min。PEF变异性水平与身高之间存在高度相关性(5.1)。同时,PEF水平与体重指数(BMI)之间存在中度相关性(1.47)。PEF水平和年龄之间没有任何相关性。结论:根据我们的研究结果,PEF个体间的变异性取决于年龄、性别身高和BMI,然而,值得在下午4点之前测量PEF的个体间变异性。所有这些变量都是在20%的范围内获得的;然而,根据参考文献,20%的变异性被认为是正常的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
65
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信