Vertical Displacement in Unilateral Extension Base Flexible Removable Dentures.

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Nobuyuki Horie, T. Ouchi, Rumiko Nishiyama, S. Usuda, S. Morikawa, S. Asoda, T. Nakagawa
{"title":"Vertical Displacement in Unilateral Extension Base Flexible Removable Dentures.","authors":"Nobuyuki Horie, T. Ouchi, Rumiko Nishiyama, S. Usuda, S. Morikawa, S. Asoda, T. Nakagawa","doi":"10.2209/tdcpublication.2018-0068","DOIUrl":null,"url":null,"abstract":"The need for flexible thermoplastic denture base materials has increased due to patient demand for better esthetic outcomes. Designs aimed at improving esthetic outcomes can cause difficulties for prosthodontists, however, from the viewpoint of function and maintenance. Therefore, the purpose of this study was to investigate vertical displacement in unilateral extension base denture models, comparing that obtained by flexible removable dentures with that by conventional metal clasp dentures. Models of unilateral extension base flexible removable dentures for mandibular defects were prepared. Periodontal ligament and jaw mucosa were simulated using a silicone impression material. Four types of flexible removable denture, with or without a metal rest, and two metal clasp dentures made of acrylic resin as a conventional design were used as dental prostheses. The amount of vertical displacement in the defect areas was measured under a load of 50 N at the first and second molars. Among the 6 types of dentures investigated, the amount of vertical displacement was greater with flexible removable dentures than with metal clasp dentures. This vertical displacement tended to decrease significantly, however, with the use of a metal rest with the flexible removable dentures. Esteshot with a metal rest, in particular, showed the smallest amount of displacement in the flexible removable dentures (first molar, 0.265±0.007 mm; second molar, 0.423±0.008 mm). These results indicate the importance of the application of rests in unilateral extension base flexible removable dentures. It may be useful to employ a metal rest in conjunction with a flexible removable denture to reduce load on the underlying mucosa, as is done with conventional partial dentures.","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2019-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2209/tdcpublication.2018-0068","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.2018-0068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

The need for flexible thermoplastic denture base materials has increased due to patient demand for better esthetic outcomes. Designs aimed at improving esthetic outcomes can cause difficulties for prosthodontists, however, from the viewpoint of function and maintenance. Therefore, the purpose of this study was to investigate vertical displacement in unilateral extension base denture models, comparing that obtained by flexible removable dentures with that by conventional metal clasp dentures. Models of unilateral extension base flexible removable dentures for mandibular defects were prepared. Periodontal ligament and jaw mucosa were simulated using a silicone impression material. Four types of flexible removable denture, with or without a metal rest, and two metal clasp dentures made of acrylic resin as a conventional design were used as dental prostheses. The amount of vertical displacement in the defect areas was measured under a load of 50 N at the first and second molars. Among the 6 types of dentures investigated, the amount of vertical displacement was greater with flexible removable dentures than with metal clasp dentures. This vertical displacement tended to decrease significantly, however, with the use of a metal rest with the flexible removable dentures. Esteshot with a metal rest, in particular, showed the smallest amount of displacement in the flexible removable dentures (first molar, 0.265±0.007 mm; second molar, 0.423±0.008 mm). These results indicate the importance of the application of rests in unilateral extension base flexible removable dentures. It may be useful to employ a metal rest in conjunction with a flexible removable denture to reduce load on the underlying mucosa, as is done with conventional partial dentures.
单侧延伸基部柔性可摘义齿的垂直位移。
由于患者对更好的美观效果的需求,对柔性热塑性义齿基托材料的需求增加了。然而,从功能和维护的角度来看,旨在改善美观效果的设计可能会给口腔医生带来困难。因此,本研究的目的是研究单侧延伸基托义齿模型的垂直位移,将柔性可摘义齿与传统金属卡环义齿的垂直位移进行比较。制备了单侧可扩基柔性可摘义齿修复下颌骨缺损的模型。使用硅胶印模材料模拟牙周韧带和颌粘膜。四种类型的柔性可摘义齿,带或不带金属支架,以及两种传统设计的丙烯酸树脂制成的金属扣义齿被用作假牙。在第一和第二磨牙处在50N的负载下测量缺陷区域中的垂直位移量。在研究的6种义齿中,柔性可摘义齿的垂直位移量大于金属卡环义齿。然而,使用带柔性可摘义齿的金属支架后,这种垂直位移往往会显著减少。特别是使用金属支架的Esteshot显示,柔性可摘义齿的位移量最小(第一磨牙,0.265±0.007 mm;第二磨牙,0.423±0.008 mm)。这些结果表明了在单侧扩展基部柔性可摘义齿中应用支架的重要性。与传统的局部义齿一样,将金属支架与柔性可摘义齿结合使用以减少下层粘膜上的负荷可能是有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bulletin of Tokyo Dental College
Bulletin of Tokyo Dental College DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
0.00%
发文量
15
期刊介绍: The bulletin of Tokyo Dental collegue is principally for the publication of original contributions to multidisciplinary research in dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信