{"title":"Modeling dipolar excitation for quadrupole mass filter","authors":"A. Konenkov, N. Konenkov, A. Sysoev","doi":"10.1177/14690667221087515","DOIUrl":null,"url":null,"abstract":"The results of modeling AC and DC dipole excitation of ion oscillations in a quadrupole mass filter are presented. The simulation is done by numerical integration of the ion motion equations, ions’ initial coordinates and velocities are distributed normally. For AC dipole excitation the instability bands on the (a, q) stability diagram follow along the isolines β x / 2 and β y / 2 , creating regular dips on the transmission contour. We show that AC excitation at frequency Ω/2 makes it possible to control the resolution of the mass filter by either changing the AC amplitude or phase. Instability bands can be used for mass selective excitation in a linear ion trap. Options for the joint use of DC and AC dipole excitation to form the mass peak shape are considered.","PeriodicalId":12007,"journal":{"name":"European Journal of Mass Spectrometry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667221087515","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The results of modeling AC and DC dipole excitation of ion oscillations in a quadrupole mass filter are presented. The simulation is done by numerical integration of the ion motion equations, ions’ initial coordinates and velocities are distributed normally. For AC dipole excitation the instability bands on the (a, q) stability diagram follow along the isolines β x / 2 and β y / 2 , creating regular dips on the transmission contour. We show that AC excitation at frequency Ω/2 makes it possible to control the resolution of the mass filter by either changing the AC amplitude or phase. Instability bands can be used for mass selective excitation in a linear ion trap. Options for the joint use of DC and AC dipole excitation to form the mass peak shape are considered.
期刊介绍:
JMS - European Journal of Mass Spectrometry, is a peer-reviewed journal, devoted to the publication of innovative research in mass spectrometry. Articles in the journal come from proteomics, metabolomics, petroleomics and other areas developing under the umbrella of the “omic revolution”.