Differences in the salivary flow rate, buffer capacity, and pH, based on the length of inhalants usage in bronchial asthma patients

Naomi Tio Agustine Sinaga, Rosilawati Wihardja, K. I. Sari
{"title":"Differences in the salivary flow rate, buffer capacity, and pH, based on the length of inhalants usage in bronchial asthma patients","authors":"Naomi Tio Agustine Sinaga, Rosilawati Wihardja, K. I. Sari","doi":"10.24198/pjd.vol34no1.29617","DOIUrl":null,"url":null,"abstract":"Introduction: Asthma or bronchial asthma is a chronic respiratory tract inflammation process involving many cells, including their elements, and can cause severe and plentiful responses from the respiratory tract. Administration of inhalation drugs is the primary medication in treating bronchial asthma. Inhalants are given appropriately with dosage and usage period based on the severity level of bronchial asthma. This research aimed to analyse the differences in the salivary flow rate, buffer, and pH, based on the length of inhalants usage in bronchial asthma patients. Methods: The research was descriptive-comparative involving 40 bronchial asthma patients (6 male and 34 female) from the Community Lung Health Center of Bandung, taken as samples using the central theorem limit sampling method. The subjects were ordered to collect their saliva in the saliva collection cups with a draining method. Then, the salivary flow rate, buffer, and pH were examined. Data distribution was tested, resulting in normally distributed data; thus, a parametric independent t-test with a significant level of 0.05 was applied. Results: Subjects in the group of inhalant usage for more than ten years had low and very low categories of salivary flow rate, buffer, and pH. There were significant differences in the salivary flow rate, buffer, and pH of the bronchial asthma patients based on their length of inhalants usage (1-5 years; >5 years–10 years; >10 years; p<0.05). Conclusions: There are differences in the salivary flow rate, buffer, and pH based on the length of inhalants usage in bronchial asthma patients. The longer the usage period, the lower the salivary flow rate, buffer, and pH.","PeriodicalId":31757,"journal":{"name":"Padjadjaran Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Padjadjaran Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24198/pjd.vol34no1.29617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Asthma or bronchial asthma is a chronic respiratory tract inflammation process involving many cells, including their elements, and can cause severe and plentiful responses from the respiratory tract. Administration of inhalation drugs is the primary medication in treating bronchial asthma. Inhalants are given appropriately with dosage and usage period based on the severity level of bronchial asthma. This research aimed to analyse the differences in the salivary flow rate, buffer, and pH, based on the length of inhalants usage in bronchial asthma patients. Methods: The research was descriptive-comparative involving 40 bronchial asthma patients (6 male and 34 female) from the Community Lung Health Center of Bandung, taken as samples using the central theorem limit sampling method. The subjects were ordered to collect their saliva in the saliva collection cups with a draining method. Then, the salivary flow rate, buffer, and pH were examined. Data distribution was tested, resulting in normally distributed data; thus, a parametric independent t-test with a significant level of 0.05 was applied. Results: Subjects in the group of inhalant usage for more than ten years had low and very low categories of salivary flow rate, buffer, and pH. There were significant differences in the salivary flow rate, buffer, and pH of the bronchial asthma patients based on their length of inhalants usage (1-5 years; >5 years–10 years; >10 years; p<0.05). Conclusions: There are differences in the salivary flow rate, buffer, and pH based on the length of inhalants usage in bronchial asthma patients. The longer the usage period, the lower the salivary flow rate, buffer, and pH.
支气管哮喘患者唾液流速、缓冲容量和pH值的差异,基于吸入剂的使用时间
引言:哮喘或支气管哮喘是一种涉及许多细胞(包括其成分)的慢性呼吸道炎症过程,可引起呼吸道严重而丰富的反应。吸入性药物是治疗支气管哮喘的主要药物。根据支气管哮喘的严重程度,按剂量和使用期适当给予吸入剂。本研究旨在根据支气管哮喘患者使用吸入剂的时间长短,分析唾液流速、缓冲液和pH值的差异。方法:采用中心定理极限抽样法,对万隆社区肺健康中心40例支气管哮喘患者(男6例,女34例)进行描述性比较研究。受试者被要求用排水法在唾液收集杯中收集唾液。然后,检查唾液流速、缓冲液和pH。对数据分布进行了测试,得出了正态分布的数据;因此,应用了显著水平为0.05的参数独立t检验。结果:在使用吸入剂超过十年的组中,受试者的唾液流速、缓冲液和pH值分别为低和极低,以及支气管哮喘患者基于吸入剂使用长度的pH值(1-5年;>5年–10年;>10年;p<0.05)。结论:支气管哮喘患者的唾液流速、缓冲液和pH值根据吸入剂使用时间存在差异。使用时间越长,唾液流速、缓冲液和pH值越低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
26
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信