{"title":"Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors","authors":"T. Ishikawa, Naoto Igarashi, N. Kurita","doi":"10.1155/2017/2716814","DOIUrl":null,"url":null,"abstract":"Since a high degree of reliability is necessary for permanent magnet synchronous motors, the detection of a precursor for the demagnetization of permanent magnets is very important. This paper investigates the diagnosis of very slight PM demagnetization. The permanent magnet volume is altered so as to mimic the effect of demagnetization. This paper investigates the influence of demagnetization by using several methods: the 3D finite element analysis (FEA) of the motor, the measurement of high-frequency impedance, and the measurement and FEA of the stator voltage and current under vector control. We have obtained the following results. The back-EMF is proportional to permanent magnet volume, and there is no difference in the demagnetization in the radial direction and in the axial direction. Even harmonics and subharmonics of flux density at the teeth tip could be useful for diagnosis if a search coil is installed there. The relatively low frequency resistance at the -axis position is useful for diagnosis. Under vector control, the stator voltage is useful except in an intermediate torque range, and the intermediate torque is expressed by a simple equation.","PeriodicalId":46335,"journal":{"name":"International Journal of Rotating Machinery","volume":"2017 1","pages":"1-13"},"PeriodicalIF":0.9000,"publicationDate":"2017-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2017/2716814","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Rotating Machinery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2017/2716814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 8
Abstract
Since a high degree of reliability is necessary for permanent magnet synchronous motors, the detection of a precursor for the demagnetization of permanent magnets is very important. This paper investigates the diagnosis of very slight PM demagnetization. The permanent magnet volume is altered so as to mimic the effect of demagnetization. This paper investigates the influence of demagnetization by using several methods: the 3D finite element analysis (FEA) of the motor, the measurement of high-frequency impedance, and the measurement and FEA of the stator voltage and current under vector control. We have obtained the following results. The back-EMF is proportional to permanent magnet volume, and there is no difference in the demagnetization in the radial direction and in the axial direction. Even harmonics and subharmonics of flux density at the teeth tip could be useful for diagnosis if a search coil is installed there. The relatively low frequency resistance at the -axis position is useful for diagnosis. Under vector control, the stator voltage is useful except in an intermediate torque range, and the intermediate torque is expressed by a simple equation.
期刊介绍:
This comprehensive journal provides the latest information on rotating machines and machine elements. This technology has become essential to many industrial processes, including gas-, steam-, water-, or wind-driven turbines at power generation systems, and in food processing, automobile and airplane engines, heating, refrigeration, air conditioning, and chemical or petroleum refining. In spite of the importance of rotating machinery and the huge financial resources involved in the industry, only a few publications distribute research and development information on the prime movers. This journal is the first source to combine the technology, as it applies to all of these specialties, previously scattered throughout literature.