Agreement of HVID/WTW measurements made by 5 devices and their correspondence to the distance from angle to angle (ATA)

Q4 Medicine
I. Saliev
{"title":"Agreement of HVID/WTW measurements made by 5 devices and their correspondence to the distance from angle to angle (ATA)","authors":"I. Saliev","doi":"10.31288/oftalmolzh202331518","DOIUrl":null,"url":null,"abstract":"Purpose: to determine the consistency of HVID/WTW measurements on 5 devices, and their correspondence to the distance from angle to angle (ATA).\nMethods\nThe relevant information on 30 right eyes was obtained from 30 volunteers. A prospective study was conducted using Wavelight Topolayzer Vario (Alcon), IOL Master 700 (Zeiss), OA2000 (Tomey), AS-OCT Casia 2 (Tomey), Zeiss Atlas 9000 (Carl Zeiss) instruments. Agreement between the measurement s made by these devices in the HVID/WTW was analyzed, and the HVID/WTW scores of each device were compared with ATA scores.\nResults\nThe average values ​ ​ of HVID/WTW in Wavelight Topolayzer Vario, IOL Master 700, OA2000, Zeiss Atlas 9000 devices were 11.73 ± 0.33 mm, 12.01 ± 0.34 mm, 12.01 ± 0.27 mm, and 12.2 ± 0.37 mm, respectively. The mean ATA was 11.68 mm on the AS-OCT Casia2 device. The smallest difference in ATA and HVID/WTW was observed on the Wavelight Topolyzer Vario instrument which averaged 0.05±0.102mm 95% LoA (-0.41 to 0.32) (p < 0.05). The largest difference was observed between AS-OCT Casia 2 and Atlas 9000 which averaged 0.52±0.234mm 95% LoA (from-1.21 to 0.17) (p < 0.05).\nConclusion\nOur study found that the results of measurements of HVID/WTW on the Wavelight Topolayzer Vario device are optimal when compared with ATA.","PeriodicalId":19419,"journal":{"name":"Oftalmologicheskii zhurnal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oftalmologicheskii zhurnal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31288/oftalmolzh202331518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: to determine the consistency of HVID/WTW measurements on 5 devices, and their correspondence to the distance from angle to angle (ATA). Methods The relevant information on 30 right eyes was obtained from 30 volunteers. A prospective study was conducted using Wavelight Topolayzer Vario (Alcon), IOL Master 700 (Zeiss), OA2000 (Tomey), AS-OCT Casia 2 (Tomey), Zeiss Atlas 9000 (Carl Zeiss) instruments. Agreement between the measurement s made by these devices in the HVID/WTW was analyzed, and the HVID/WTW scores of each device were compared with ATA scores. Results The average values ​ ​ of HVID/WTW in Wavelight Topolayzer Vario, IOL Master 700, OA2000, Zeiss Atlas 9000 devices were 11.73 ± 0.33 mm, 12.01 ± 0.34 mm, 12.01 ± 0.27 mm, and 12.2 ± 0.37 mm, respectively. The mean ATA was 11.68 mm on the AS-OCT Casia2 device. The smallest difference in ATA and HVID/WTW was observed on the Wavelight Topolyzer Vario instrument which averaged 0.05±0.102mm 95% LoA (-0.41 to 0.32) (p < 0.05). The largest difference was observed between AS-OCT Casia 2 and Atlas 9000 which averaged 0.52±0.234mm 95% LoA (from-1.21 to 0.17) (p < 0.05). Conclusion Our study found that the results of measurements of HVID/WTW on the Wavelight Topolayzer Vario device are optimal when compared with ATA.
5个设备进行的HVID/WTW测量的一致性及其与角度间距离(ATA)的对应关系
目的:确定5台设备HVID/WTW测量值的一致性,以及它们与角度间距离(ATA)的对应关系。方法从30名志愿者中获得30只右眼的相关信息。使用Wavellight Topolayzer Vario(Alcon)、IOL Master 700(蔡司)、OA2000(Tomey)、AS-OCT Casia 2(Tomey。分析了这些设备在HVID/WTW中进行的测量之间的一致性,并将每个设备的HVID/WTW得分与ATA得分进行了比较。结果平均值​ ​ Wavellight Topolayzer Vario、IOL Master 700、OA2000和Zeiss Atlas 9000装置的HVID/WTW分别为11.73±0.33 mm、12.01±0.34 mm、12.02±0.27 mm和12.2±0.37 mm。AS-OCT Casia2装置的平均ATA为11.68mm。在Wavelight Topolyzer Vario仪器上观察到ATA和HVID/WTW的最小差异,平均值为0.05±0.102mm 95%LoA(-0.41至0.32)(p<0.05)。AS-OCT Casia 2和Atlas 9000之间观察到最大差异,平均为0.52±0.234mm 95%LoA,从-1.21至0.17(p<0.05)Topolayzer Vario设备与ATA相比是最佳的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Oftalmologicheskii zhurnal
Oftalmologicheskii zhurnal Medicine-Ophthalmology
CiteScore
0.40
自引率
0.00%
发文量
71
期刊介绍: Journal of Ophthalmology (Ukraine) contains articles on eye diseases diagnosis and treatment, eye care, eye diseases prevention, history of ophthalmology, organization of eye care to population, technical equipment problems. It is committed to publishing original scientific researches and review articles on theory and practice of Ukrainian and foreign ophthalmology, cases, reviews, inventions, historical and medical reviews. It contains peer-reviews of books on ophthalmology, articles on activity of ophthalmologic societies, congresses and conferences chronicles. Journal is designed to ophthalmologists and scientific researchers in the field of vision physiology and eye diseases clinic.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信