Lung Diffusing Capacity in Dutch Special Operations Forces Divers Exposed to Oxygen Rebreathers over 18 Years

Tom H.B. den Ouden, T. Wingelaar, E. Endert, P. V. van Ooij
{"title":"Lung Diffusing Capacity in Dutch Special Operations Forces Divers Exposed to Oxygen Rebreathers over 18 Years","authors":"Tom H.B. den Ouden, T. Wingelaar, E. Endert, P. V. van Ooij","doi":"10.3390/oxygen2020005","DOIUrl":null,"url":null,"abstract":"Exposure to hyperoxic conditions can induce pulmonary oxygen toxicity (POT). Divers of the Special Operations Forces (SOF) use oxygen rebreather systems during dives, and therefore are frequently exposed to hyperoxic conditions. Few studies have reported on POT in this population. This study reports on long-term pulmonary function tests (PFTs) and diffusing capacity in SOF divers to test the hypothesis that these measures of pulmonary function do not change clinically significantly during their career. The Royal Netherlands Navy performs yearly medical assessments of its military divers. All PFT and diffusing capacity data of SOF divers between the years 2000 and 2020 were analyzed using generalized estimating equations. The study included 257 SOF divers (median age, 27; interquartile range, 24–32), with 1612 dive medical assessments and a maximum follow-up time of 18.8 years. Alveolar volume (VA) and the diffusing capacity of carbon monoxide (TLCO) were significantly lower at baseline in smokers. Although these parameters were within the normal range, they declined over time and were significantly associated with age and years of diving. Smoking additionally affected TLCO and the transfer coefficient for carbon monoxide (KCO). TLCO and KCO were reduced by years of diving with oxygen rebreathers, albeit over clinically insignificant ranges, but smoking increased these changes by factors of 10 and 15, respectively.","PeriodicalId":74387,"journal":{"name":"Oxygen (Basel, Switzerland)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oxygen (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/oxygen2020005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Exposure to hyperoxic conditions can induce pulmonary oxygen toxicity (POT). Divers of the Special Operations Forces (SOF) use oxygen rebreather systems during dives, and therefore are frequently exposed to hyperoxic conditions. Few studies have reported on POT in this population. This study reports on long-term pulmonary function tests (PFTs) and diffusing capacity in SOF divers to test the hypothesis that these measures of pulmonary function do not change clinically significantly during their career. The Royal Netherlands Navy performs yearly medical assessments of its military divers. All PFT and diffusing capacity data of SOF divers between the years 2000 and 2020 were analyzed using generalized estimating equations. The study included 257 SOF divers (median age, 27; interquartile range, 24–32), with 1612 dive medical assessments and a maximum follow-up time of 18.8 years. Alveolar volume (VA) and the diffusing capacity of carbon monoxide (TLCO) were significantly lower at baseline in smokers. Although these parameters were within the normal range, they declined over time and were significantly associated with age and years of diving. Smoking additionally affected TLCO and the transfer coefficient for carbon monoxide (KCO). TLCO and KCO were reduced by years of diving with oxygen rebreathers, albeit over clinically insignificant ranges, but smoking increased these changes by factors of 10 and 15, respectively.
荷兰特种作战部队潜水员暴露于氧气再呼吸装置18年的肺扩散能力
暴露在高氧条件下可诱发肺氧毒性(POT)。特种作战部队(SOF)的潜水员在潜水过程中使用氧气再呼吸系统,因此经常暴露在高氧条件下。很少有研究报道这种人群中的POT。本研究报告了SOF潜水员的长期肺功能测试(PFTs)和扩散能力,以检验这些肺功能测量在其职业生涯中不会发生临床显著变化的假设。荷兰皇家海军每年对其军事潜水员进行医疗评估。使用广义估计方程分析了2000年至2020年间SOF潜水员的所有PFT和扩散能力数据。该研究包括257名SOF潜水员(中位年龄为27岁;四分位间距为24-32岁),进行了1612次潜水医学评估,最长随访时间为18.8年。吸烟者的肺泡容积(VA)和一氧化碳扩散能力(TLCO)在基线时显著降低。尽管这些参数在正常范围内,但随着时间的推移,它们会下降,并且与年龄和潜水年限显著相关。吸烟还影响TLCO和一氧化碳(KCO)的传递系数。使用氧气呼吸器潜水多年后,TLCO和KCO降低,尽管在临床上不显著,但吸烟使这些变化分别增加了10和15倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信