{"title":"Review of large-scale fire tests on cross-laminated timber","authors":"G. Ronquillo, D. Hopkin, M. Spearpoint","doi":"10.1177/07349041211034460","DOIUrl":null,"url":null,"abstract":"Concerns about the environmental impact of building construction is leading to timber being more commonly used. However, it often faces scepticism regarding its safety in the event of fire. This article provides a point of reference on the fire performance of cross-laminated timber through a review of large-scale tests. Although adequately protecting CLT can make its contribution to fire insignificant, some of the internal surface of an enclosure can be exposed whilst still achieving adequate fire performance. Natural fire tests show that the charring rate and zero-strength layer thickness are higher than commonly used in guidance documents. The type of adhesive used to bond lamellae influences performance where delamination can lead to secondary flashovers, particularly in smaller enclosures. Structural elements can potentially collapse without self-extinction and/or suppression intervention. Tests to date have focussed on a residential context and knowledge gaps remain regarding larger enclosures, such as office-type buildings.","PeriodicalId":15772,"journal":{"name":"Journal of Fire Sciences","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Fire Sciences","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/07349041211034460","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 11
Abstract
Concerns about the environmental impact of building construction is leading to timber being more commonly used. However, it often faces scepticism regarding its safety in the event of fire. This article provides a point of reference on the fire performance of cross-laminated timber through a review of large-scale tests. Although adequately protecting CLT can make its contribution to fire insignificant, some of the internal surface of an enclosure can be exposed whilst still achieving adequate fire performance. Natural fire tests show that the charring rate and zero-strength layer thickness are higher than commonly used in guidance documents. The type of adhesive used to bond lamellae influences performance where delamination can lead to secondary flashovers, particularly in smaller enclosures. Structural elements can potentially collapse without self-extinction and/or suppression intervention. Tests to date have focussed on a residential context and knowledge gaps remain regarding larger enclosures, such as office-type buildings.
期刊介绍:
The Journal of Fire Sciences is a leading journal for the reporting of significant fundamental and applied research that brings understanding of fire chemistry and fire physics to fire safety. Its content is aimed toward the prevention and mitigation of the adverse effects of fires involving combustible materials, as well as development of new tools to better address fire safety needs. The Journal of Fire Sciences covers experimental or theoretical studies of fire initiation and growth, flame retardant chemistry, fire physics relative to material behavior, fire containment, fire threat to people and the environment and fire safety engineering. This journal is a member of the Committee on Publication Ethics (COPE).