Bonnie Y Chien, Eitan M Ingall, Steven Staffa, Caroline Williams, Christopher P Miller, John Y Kwon
{"title":"Are SER-II Ankle Fractures Anatomic? Computed Tomography Demonstrates Mortise Malalignment in the Setting of Apparently Normal Radiographs.","authors":"Bonnie Y Chien, Eitan M Ingall, Steven Staffa, Caroline Williams, Christopher P Miller, John Y Kwon","doi":"10.1177/19386400221093861","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ankle fracture treatment is predicated on minimal displacement, leading to abnormal joint contact area. The purpose of this investigation is to determine whether computed tomography (CT) detects subtle mortise malalignment undetectable by x-ray in supination-external rotation-II (SER-II) injuries.</p><p><strong>Methods: </strong>A total of 24 patients with SER-II injuries, as demonstrated by negative gravity stress radiography, were included. Medial clear space (MCS) measurements were performed on bilateral ankle x-rays (injured and contralateral, uninjured side) at several time points as well as bilateral non-weight-bearing CT performed once clinical and radiographic healing was demonstrated (mean = 66 days post injury, range = 61-105 days). Statistical analyses examined differences in measurements between both sides.</p><p><strong>Results: </strong>Final x-rays demonstrated no differences between normal and injured ankle MCS (P = .441). However, CT coronal/axial MCS measurements were different (P < .05). CT coronal MCS measured wider by a mean difference of 0.67 mm (P < .001).</p><p><strong>Conclusion: </strong>There is a high incidence of subtle mortise malalignment in SER-II ankle fractures, as demonstrated by CT, which is undetectable when assessed by plain radiographs. Although clinical outcomes are yet unknown, there are important implications of the finding of confirmed, subtle mortise malalignment in SER-II injuries and the limitations of x-ray to detect it.</p><p><strong>Level of evidence: </strong>Level III.</p>","PeriodicalId":39271,"journal":{"name":"Foot and Ankle Specialist","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2022-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Specialist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19386400221093861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Ankle fracture treatment is predicated on minimal displacement, leading to abnormal joint contact area. The purpose of this investigation is to determine whether computed tomography (CT) detects subtle mortise malalignment undetectable by x-ray in supination-external rotation-II (SER-II) injuries.
Methods: A total of 24 patients with SER-II injuries, as demonstrated by negative gravity stress radiography, were included. Medial clear space (MCS) measurements were performed on bilateral ankle x-rays (injured and contralateral, uninjured side) at several time points as well as bilateral non-weight-bearing CT performed once clinical and radiographic healing was demonstrated (mean = 66 days post injury, range = 61-105 days). Statistical analyses examined differences in measurements between both sides.
Results: Final x-rays demonstrated no differences between normal and injured ankle MCS (P = .441). However, CT coronal/axial MCS measurements were different (P < .05). CT coronal MCS measured wider by a mean difference of 0.67 mm (P < .001).
Conclusion: There is a high incidence of subtle mortise malalignment in SER-II ankle fractures, as demonstrated by CT, which is undetectable when assessed by plain radiographs. Although clinical outcomes are yet unknown, there are important implications of the finding of confirmed, subtle mortise malalignment in SER-II injuries and the limitations of x-ray to detect it.