Measurement of the Workplace Protection Factor of Replaceable Particulate and Powered Air-purifying Respirators in Japanese Dust-generating Occupations.

Q3 Medicine
Shingo Sekoguchi, H. Ando, K. Ikegami, Hidetaka Yoshitake, Hiroka Baba, A. Ogami
{"title":"Measurement of the Workplace Protection Factor of Replaceable Particulate and Powered Air-purifying Respirators in Japanese Dust-generating Occupations.","authors":"Shingo Sekoguchi, H. Ando, K. Ikegami, Hidetaka Yoshitake, Hiroka Baba, A. Ogami","doi":"10.7888/juoeh.44.15","DOIUrl":null,"url":null,"abstract":"Although measuring the workplace protection factor (WPF) is important to verify the performance of particulate respirators in a real work environment, there are no reports of such measurements in Japan. The aim of this study was to measure the WPF of a replaceable particulate respirator (RPR) and a powered air-purifying respirator (PAPR). Eight participants were subjected to three conditions: wearing a RPR correctly (C-RPR), wearing a RPR as usual (but incorrectly) (U-RPR), and wearing a PAPR in the same way as U-RPR (PAPR). Subjects performed dust-generating tasks for 15 min, during which the WPF was measured. The WPF was calculated by dividing the concentration of particles outside the particulate respirator (Co) by that inside the particulate respirator (Ci). A fit testing instrument was used to measure the number of particles. Ci was measured by inserting the test guide into the face piece, and Co was measured by fixing the test guide near the breathing area of the subjects. The WPF geometric mean values (standard deviations) for C-RPR, U-RPR, and PAPR were 17.7 (2.59), 27.0 (3.86), and 117.3 (5.25), respectively. It is important to generate knowledge about the performance of particulate respirators to prevent occupational respiratory diseases.","PeriodicalId":17570,"journal":{"name":"Journal of UOEH","volume":"44 1 1","pages":"15-24"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of UOEH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7888/juoeh.44.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3

Abstract

Although measuring the workplace protection factor (WPF) is important to verify the performance of particulate respirators in a real work environment, there are no reports of such measurements in Japan. The aim of this study was to measure the WPF of a replaceable particulate respirator (RPR) and a powered air-purifying respirator (PAPR). Eight participants were subjected to three conditions: wearing a RPR correctly (C-RPR), wearing a RPR as usual (but incorrectly) (U-RPR), and wearing a PAPR in the same way as U-RPR (PAPR). Subjects performed dust-generating tasks for 15 min, during which the WPF was measured. The WPF was calculated by dividing the concentration of particles outside the particulate respirator (Co) by that inside the particulate respirator (Ci). A fit testing instrument was used to measure the number of particles. Ci was measured by inserting the test guide into the face piece, and Co was measured by fixing the test guide near the breathing area of the subjects. The WPF geometric mean values (standard deviations) for C-RPR, U-RPR, and PAPR were 17.7 (2.59), 27.0 (3.86), and 117.3 (5.25), respectively. It is important to generate knowledge about the performance of particulate respirators to prevent occupational respiratory diseases.
日本粉尘产生职业中可替换颗粒和动力空气净化呼吸器工作场所防护系数的测量。
虽然测量工作场所防护系数(WPF)对于验证颗粒呼吸器在真实工作环境中的性能很重要,但在日本没有此类测量的报告。本研究的目的是测量可更换颗粒呼吸器(RPR)和动力空气净化呼吸器(PAPR)的WPF。八名参与者接受了三种条件:正确佩戴RPR (C-RPR),正常佩戴RPR(但不正确)(U-RPR),以及以与U-RPR相同的方式佩戴PAPR (PAPR)。受试者执行产生粉尘的任务15分钟,在此期间测量WPF。WPF的计算方法是用颗粒物呼吸器外颗粒物浓度(Co)除以颗粒物呼吸器内颗粒物浓度(Ci)。采用拟合测试仪测量颗粒数。将测试导具插入面部片测量Ci,将测试导具固定在受试者呼吸区附近测量Co。C-RPR、U-RPR和PAPR的WPF几何平均值(标准差)分别为17.7(2.59)、27.0(3.86)和117.3(5.25)。了解微粒呼吸器的性能对预防职业性呼吸道疾病非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of UOEH
Journal of UOEH Medicine-Medicine (all)
CiteScore
1.30
自引率
0.00%
发文量
35
期刊介绍: Published quarterly: 1 annual volume consisted of 4 numbers. Issued on the 1st of March, June, September and December, respectively.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信