M. Singhal, Sankey Kumar Baidya, Astha Khurana, Mehjabeen Kouser
{"title":"A Comparative Measurement of Edentulous Bone Between Cone Beam Computed Tomography vs. Dentascan CT in Implant Patients: In Vivo Study","authors":"M. Singhal, Sankey Kumar Baidya, Astha Khurana, Mehjabeen Kouser","doi":"10.18311/jpfa/2022/27714","DOIUrl":null,"url":null,"abstract":"Aim: To compare the linear and mesiodistal measurement of alveolar edentulous bone between CBCT and Dentascan CT. Vivo-comparative study. Materials and Methods: 30 implant patients were selected among the partially edentulous ridge in pre-maxillary region. After using a radiographic stent splint (3×3 mm square), a CBCT and Dentascan was scanned. Linear and mesiodistal radiographic evaluations were performed from a built-in software tool. The student unpaired t-test was used for finding significant difference in between and within group. P-value less than 0.05 was considered to be statistically significant. Results: Linear Radiographic Evaluation by Dentascan was 20.75 ± 2.14 and by CBCT was 20.86 ± 2.18, Mesiodistal Radiographic Evaluation by Dentascan was 6.71 ± 0.70 and by CBCT was 6.79 ± 0.70. Conclusion: The linear assessment of the implant site taken on Dentascan was almost similar to that recorded on CBCT and P-value is not significant (>0.05).","PeriodicalId":77222,"journal":{"name":"Journal of Pierre Fauchard Academy (Pierre Fauchard Academy. India Section)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pierre Fauchard Academy (Pierre Fauchard Academy. India Section)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18311/jpfa/2022/27714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: To compare the linear and mesiodistal measurement of alveolar edentulous bone between CBCT and Dentascan CT. Vivo-comparative study. Materials and Methods: 30 implant patients were selected among the partially edentulous ridge in pre-maxillary region. After using a radiographic stent splint (3×3 mm square), a CBCT and Dentascan was scanned. Linear and mesiodistal radiographic evaluations were performed from a built-in software tool. The student unpaired t-test was used for finding significant difference in between and within group. P-value less than 0.05 was considered to be statistically significant. Results: Linear Radiographic Evaluation by Dentascan was 20.75 ± 2.14 and by CBCT was 20.86 ± 2.18, Mesiodistal Radiographic Evaluation by Dentascan was 6.71 ± 0.70 and by CBCT was 6.79 ± 0.70. Conclusion: The linear assessment of the implant site taken on Dentascan was almost similar to that recorded on CBCT and P-value is not significant (>0.05).