The role of mitral annular plane systolic excursion in prediction of acute blood loss in healthy voluntary blood donors

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Birdal Güllüpınar, C. Sağlam, Serhat Koran, A. Turhan, E. E. Ünlüer
{"title":"The role of mitral annular plane systolic excursion in prediction of acute blood loss in healthy voluntary blood donors","authors":"Birdal Güllüpınar, C. Sağlam, Serhat Koran, A. Turhan, E. E. Ünlüer","doi":"10.15557/JoU.2022.0006","DOIUrl":null,"url":null,"abstract":"Abstract Aim The aim of this study is to compare the diameter of the inferior vena cava with mitral annular plane systolic excursion measurement in order to determine the volume loss before and after blood donation in healthy volunteers. Material and methods The study was a single-center, prospective, cross-sectional study which included 46 healthy blood donors donating in a tertiary care hospital’s blood bank. The inclusion criteria for the study were: volunteers aged 18–65 years, over 50 kg in weight, who met blood donation criteria, with hemoglobin values of >13.5 g/dL for males and >12.5 g/dL for females. After obtaining written consent, the systolic, diastolic, and mean arterial blood pressure along with the pulse rate of the donors were measured in standing and lying positions by the attending physician. Next, inferior vena cava and mitral annular plane systolic excursion measurements were made both pre and post blood donation. Results The decrease in both inferior vena cava diameter and mitral annular plane systolic excursion values measured pre and post blood donation was found to be statistically significant (p <0.05). There was no difference between the other variables pre and post blood donation. Conclusions Our study revealed that decreased inferior vena cava and mitral annular plane systolic excursion values correlated in determining blood loss post blood donation. Mitral annular plane systolic excursion may be useful to predict blood loss in the early stages of hemorrhagic shock.","PeriodicalId":45612,"journal":{"name":"Journal of Ultrasonography","volume":"22 1","pages":"e33 - e38"},"PeriodicalIF":1.3000,"publicationDate":"2022-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15557/JoU.2022.0006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Aim The aim of this study is to compare the diameter of the inferior vena cava with mitral annular plane systolic excursion measurement in order to determine the volume loss before and after blood donation in healthy volunteers. Material and methods The study was a single-center, prospective, cross-sectional study which included 46 healthy blood donors donating in a tertiary care hospital’s blood bank. The inclusion criteria for the study were: volunteers aged 18–65 years, over 50 kg in weight, who met blood donation criteria, with hemoglobin values of >13.5 g/dL for males and >12.5 g/dL for females. After obtaining written consent, the systolic, diastolic, and mean arterial blood pressure along with the pulse rate of the donors were measured in standing and lying positions by the attending physician. Next, inferior vena cava and mitral annular plane systolic excursion measurements were made both pre and post blood donation. Results The decrease in both inferior vena cava diameter and mitral annular plane systolic excursion values measured pre and post blood donation was found to be statistically significant (p <0.05). There was no difference between the other variables pre and post blood donation. Conclusions Our study revealed that decreased inferior vena cava and mitral annular plane systolic excursion values correlated in determining blood loss post blood donation. Mitral annular plane systolic excursion may be useful to predict blood loss in the early stages of hemorrhagic shock.
二尖瓣环平面收缩偏移在健康自愿献血者急性失血预测中的作用
摘要目的比较健康志愿者献血前后下腔静脉内径与二尖瓣环面收缩位移测量的差异,以确定献血前后的容量损失。材料与方法本研究为单中心、前瞻性、横断面研究,纳入46名在三级医院血库献血的健康献血者。本研究纳入标准为:年龄18-65岁,体重50公斤以上,符合献血标准,男性血红蛋白值>为13.5 g/dL,女性血红蛋白值>为12.5 g/dL的志愿者。获得书面同意后,由主治医师测量供者站立和躺卧体位的收缩压、舒张压、平均动脉血压及脉搏率。然后,在献血前后分别测量下腔静脉和二尖瓣环面收缩偏移。结果献血前后下腔静脉内径和二尖瓣环面收缩偏移值下降,差异均有统计学意义(p <0.05)。献血前后的其他变量没有差异。结论:我们的研究显示下腔静脉和二尖瓣环面收缩偏移值的减少与献血后的出血量相关。二尖瓣收缩平面漂移可能有助于预测失血性休克早期的出血量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ultrasonography
Journal of Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.30
自引率
0.00%
发文量
58
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信