Physical dosimetric reconstruction of a case of large area back skin injury due to overexposure in an interventional procedure

Q1 Health Professions
Yuchen Yin , Xuan Wang , Xianghui Kong , Wenyue Zhang , Yidi Wang , Yuxuan Mao , Jianwei Wang , Tianhe Jia , Yu Tu , Bingjie Zhang , Liang Sun
{"title":"Physical dosimetric reconstruction of a case of large area back skin injury due to overexposure in an interventional procedure","authors":"Yuchen Yin ,&nbsp;Xuan Wang ,&nbsp;Xianghui Kong ,&nbsp;Wenyue Zhang ,&nbsp;Yidi Wang ,&nbsp;Yuxuan Mao ,&nbsp;Jianwei Wang ,&nbsp;Tianhe Jia ,&nbsp;Yu Tu ,&nbsp;Bingjie Zhang ,&nbsp;Liang Sun","doi":"10.1016/j.radmp.2022.02.001","DOIUrl":null,"url":null,"abstract":"<div><p>To estimate the physical dose of skin and key organs in a case of overexposure during a cardiac interventional procedure.</p></div><div><h3>Methods</h3><p>The female patient aged 50 suffered from overexposure during cardiac interventional therapy in a hospital, Xinxiang city, Henan province, China in January 2020. The mesh-type phantom for the patient was constructed based on the adult mesh-type reference computational phantoms (MRCPs) released by the International Commission on Radiological Protection Publication 145 (ICRP145) and phantom deformation technology. Models of exposure scenario were constructed and simulated with particle and heavy ion transport code system (PHITS) according to exposure conditions.</p></div><div><h3>Results</h3><p>The maximum absorbed dose of key organs/tissues under irradiation in posteroanterior (PA) and 30° left anterior oblique directions(LOA) was 632.4 and 305.6 ​mGy, respectively. The left lung, heart, and left mammary gland received a larger dose under both irradiation conditions. The ratio of the absorbed dose with and without shielding was calculated, and the relative difference in most organs was &lt;1% between two directions. The iso-dose curve of the back skin revealed the distribution of the absorbed dose (0.1 −5.2 ​Gy). The dose estimate of key tissues/organs was higher than the conventional level, especially the local skin, up to 5.2 ​Gy.</p></div><div><h3>Conclusions</h3><p>The interventional procedure in this case resulted in a higher dose. Monte Carlo codes combined with the MRCPs can be employed to estimate physical dose to individuals in concrete irradiation scenarios.</p></div>","PeriodicalId":34051,"journal":{"name":"Radiation Medicine and Protection","volume":"3 1","pages":"Pages 3-8"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666555722000077/pdfft?md5=8e4092fefa86378c1f65e3ca63de1758&pid=1-s2.0-S2666555722000077-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Medicine and Protection","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666555722000077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

To estimate the physical dose of skin and key organs in a case of overexposure during a cardiac interventional procedure.

Methods

The female patient aged 50 suffered from overexposure during cardiac interventional therapy in a hospital, Xinxiang city, Henan province, China in January 2020. The mesh-type phantom for the patient was constructed based on the adult mesh-type reference computational phantoms (MRCPs) released by the International Commission on Radiological Protection Publication 145 (ICRP145) and phantom deformation technology. Models of exposure scenario were constructed and simulated with particle and heavy ion transport code system (PHITS) according to exposure conditions.

Results

The maximum absorbed dose of key organs/tissues under irradiation in posteroanterior (PA) and 30° left anterior oblique directions(LOA) was 632.4 and 305.6 ​mGy, respectively. The left lung, heart, and left mammary gland received a larger dose under both irradiation conditions. The ratio of the absorbed dose with and without shielding was calculated, and the relative difference in most organs was <1% between two directions. The iso-dose curve of the back skin revealed the distribution of the absorbed dose (0.1 −5.2 ​Gy). The dose estimate of key tissues/organs was higher than the conventional level, especially the local skin, up to 5.2 ​Gy.

Conclusions

The interventional procedure in this case resulted in a higher dose. Monte Carlo codes combined with the MRCPs can be employed to estimate physical dose to individuals in concrete irradiation scenarios.

介入手术中过度暴露导致大面积背部皮肤损伤的物理剂量重建
估计心脏介入手术中皮肤和关键器官过度暴露的物理剂量。方法于2020年1月在河南省新乡市某医院接受心脏介入治疗时出现过暴露的女性患者,年龄50岁。基于国际放射防护委员会第145号出版物(ICRP145)发布的成人网格型参考计算幻影(MRCPs)和幻影变形技术,构建患者网格型幻影。根据不同的暴露条件,利用粒子和重离子输运编码系统(PHITS)建立了暴露情景模型并进行了模拟。结果后前位(PA)和30°左前斜位(LOA)照射下关键器官/组织的最大吸收剂量分别为632.4和305.6 mGy。在两种照射条件下,左肺、心脏和左乳腺接受的剂量都较大。计算了有屏蔽与无屏蔽的吸收剂量之比,两个方向上大多数器官的相对差异为1%。背部皮肤等剂量曲线显示吸收剂量分布(0.1 ~ 5.2 Gy)。关键组织/器官的剂量估计高于常规水平,特别是局部皮肤,高达5.2 Gy。结论本病例的介入治疗导致了较高的剂量。蒙特卡罗代码结合mrcp可用于估算具体辐照情景下个人的物理剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation Medicine and Protection
Radiation Medicine and Protection Health Professions-Emergency Medical Services
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
103 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信