Malachite Green-Based Detection of SARS-CoV-2 by One-Step Reverse Transcription Loop-Mediated Isothermal Amplification

IF 1.4 4区 综合性期刊 Q2 MULTIDISCIPLINARY SCIENCES
Reyhaneh Tavakoli-Koopaei, Fatemeh Javadi-Zarnaghi, Shima Aboutalebian, Hossein Mirhendi
{"title":"Malachite Green-Based Detection of SARS-CoV-2 by One-Step Reverse Transcription Loop-Mediated Isothermal Amplification","authors":"Reyhaneh Tavakoli-Koopaei,&nbsp;Fatemeh Javadi-Zarnaghi,&nbsp;Shima Aboutalebian,&nbsp;Hossein Mirhendi","doi":"10.1007/s40995-022-01392-5","DOIUrl":null,"url":null,"abstract":"<div><p>The pandemic of severe acute respiratory syndrome 2 (SARS-CoV-2) revealed the necessity of diagnosis of the infected people to prevent the prevalence infection cycle. Many commercial pathogen diagnosis methods are based on the detection of genomic materials. Isothermal amplification methods such as loop-mediated-isothermal amplification (LAMP) are the method of choice in these cases. Reverse transcription steps are efficiently coupled to LAMP for the detection of pathogens with genomic RNAs such as SARS-CoV-2. Many detection systems for LAMP include fluorescent readout systems. Although such systems result in desirable limits of detection, the need for special instrumentation is the main dispute of such systems to become real point of care assays. In contrast, colorimetric detection methods would reduce costs and improve the applicability of the system. In this study one-step reverse transcription-LAMP reaction was established that enables visual detection of the SARS-CoV-2 genome. Nasopharyngeal RNA samples were first validated by reverse transcription quantitative polymerase chain reaction and then subjected to RT-LAMP. To lower the cost associated with the readout system equipment, malachite green (MG) was used. The color change of MG to blue allowed visual detection of the virus. Firstly, experiments were set up as two-step RT-LAMP reaction to identify the best primer sets. In addition, MG concentration was optimized with the significant colorimetric signal for the positive samples. Next, a one-step colorimetric method was developed for the detection of SARS-CoV-2 based on MG color shift in 2 h.</p></div>","PeriodicalId":600,"journal":{"name":"Iranian Journal of Science and Technology, Transactions A: Science","volume":"47 2","pages":"359 - 367"},"PeriodicalIF":1.4000,"publicationDate":"2023-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Science and Technology, Transactions A: Science","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1007/s40995-022-01392-5","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The pandemic of severe acute respiratory syndrome 2 (SARS-CoV-2) revealed the necessity of diagnosis of the infected people to prevent the prevalence infection cycle. Many commercial pathogen diagnosis methods are based on the detection of genomic materials. Isothermal amplification methods such as loop-mediated-isothermal amplification (LAMP) are the method of choice in these cases. Reverse transcription steps are efficiently coupled to LAMP for the detection of pathogens with genomic RNAs such as SARS-CoV-2. Many detection systems for LAMP include fluorescent readout systems. Although such systems result in desirable limits of detection, the need for special instrumentation is the main dispute of such systems to become real point of care assays. In contrast, colorimetric detection methods would reduce costs and improve the applicability of the system. In this study one-step reverse transcription-LAMP reaction was established that enables visual detection of the SARS-CoV-2 genome. Nasopharyngeal RNA samples were first validated by reverse transcription quantitative polymerase chain reaction and then subjected to RT-LAMP. To lower the cost associated with the readout system equipment, malachite green (MG) was used. The color change of MG to blue allowed visual detection of the virus. Firstly, experiments were set up as two-step RT-LAMP reaction to identify the best primer sets. In addition, MG concentration was optimized with the significant colorimetric signal for the positive samples. Next, a one-step colorimetric method was developed for the detection of SARS-CoV-2 based on MG color shift in 2 h.

一步逆转录环介导等温扩增孔雀石绿检测SARS-CoV-2
严重急性呼吸综合征(SARS-CoV-2)大流行揭示了对感染者进行诊断以防止流行感染周期的必要性。许多商业化的病原体诊断方法都是基于基因组物质的检测。等温扩增方法,如环介导等温扩增(LAMP)是在这些情况下的选择方法。逆转录步骤与LAMP有效耦合,用于检测具有基因组rna的病原体,如SARS-CoV-2。许多LAMP检测系统包括荧光读出系统。虽然这样的系统导致了理想的检测限制,但对特殊仪器的需求是这种系统成为真正的护理点分析的主要争议。相比之下,比色检测方法将降低成本,提高系统的适用性。本研究建立了一步逆转录- lamp反应,实现了SARS-CoV-2基因组的目视检测。先用逆转录定量聚合酶链反应验证鼻咽RNA样品,然后用RT-LAMP进行验证。为了降低与读出系统设备相关的成本,使用孔雀石绿(MG)。MG的颜色变为蓝色,可以目视检测病毒。首先,采用两步RT-LAMP反应确定最佳引物组合。此外,对阳性样品的MG浓度进行了优化,得到了显著的比色信号。建立了基于MG色移2 h的一步比色法检测SARS-CoV-2的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.00
自引率
5.90%
发文量
122
审稿时长
>12 weeks
期刊介绍: The aim of this journal is to foster the growth of scientific research among Iranian scientists and to provide a medium which brings the fruits of their research to the attention of the world’s scientific community. The journal publishes original research findings – which may be theoretical, experimental or both - reviews, techniques, and comments spanning all subjects in the field of basic sciences, including Physics, Chemistry, Mathematics, Statistics, Biology and Earth Sciences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信