The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device.

IF 2.1 4区 医学 Q2 Medicine
Weitao Ye, Wanqun Yang, Cheng-wei Guo, Chenyu Dong, F. Shi, C. Liang
{"title":"The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device.","authors":"Weitao Ye, Wanqun Yang, Cheng-wei Guo, Chenyu Dong, F. Shi, C. Liang","doi":"10.5152/dir.2022.20292","DOIUrl":null,"url":null,"abstract":"PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.","PeriodicalId":50582,"journal":{"name":"Diagnostic and Interventional Radiology","volume":"28 2 1","pages":"115-123"},"PeriodicalIF":2.1000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/dir.2022.20292","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.
MWA方案对肝脏消融区形态和IVIM参数的影响- mri兼容微波消融装置的初步体内动物研究。
目的探讨微波消融(MWA)方案对猪肝MWA区形态及体素内非相干运动(IVIM)扩散加权成像(DWI)参数瞬时变化的影响。方法根据我院小于3cm肿瘤MWA的经验方案,将功率和使用时间分为5组:A、60 W × 5 min (n = 6);B, 80 W × 3 min (n = 7);C, 80 W × 5 min (n = 10);D, 100 W × 3 min (n = 10);E, 100 W × 5 min (n = 9)。对MWA方案、形态学指标和消融后即时IVIM参数进行Spearman相关性分析。结果能量传递与白区短轴呈显著正相关(RSpearman = 0.426, P= 0.005)。白带的瓦数与短轴呈中等至良好的正相关(RSpearman = 0.584, P < 0.001)。消融后白区IVIM参数中,只有瓦数与D值(RSpearman= 0.574, P < .001)或ADC值(RSpearman= 0.550, P < .001)呈正相关。能量输送、瓦数、持续时间和f值之间无相关性(RSpearman = 0.185, P = 0.24;RSpearman= - 0.001, P = 0.99;RSpearman = 0.203, P = 0.20)。结论白区短轴的增加更容易受到功率的影响,而不是能量输送的影响。消融后瞬间IVIM监测MWA区域是可行的,因为白色区域的f值对MWA协议的变化不敏感,这在评价MWA的即时效果方面是有希望的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
69
审稿时长
6-12 weeks
期刊介绍: Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English. The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信