{"title":"LC-MS/MS Method for Determination of Colistin in Human Plasma: Validation and Stability Studies","authors":"Nada H. Binhashim, S. Alvi, M. Hammami","doi":"10.4236/IJAMSC.2021.91001","DOIUrl":null,"url":null,"abstract":"A simple and reliable high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the determination of colistin A and colistin B in human plasma was developed and validated. Clarithromycin was used as an internal standard (IS). Plasma extraction was performed using C-18 cartridges and methanol containing 0.1% formic acid. Analysis was performed using Atlantis dC18 (2.1 × 100 mm, 3 μm) column at room temperature and a mobile phase of 0.2% formic acid in acetonitrile and water (50:50, v:v), delivered at a flow rate of 0.2 ml/minute. Eluent was detected in the positive ion mode using electrospray ionization at the following transitions of mass to charge (m/z): colistin A, 585.6 → 101.4; colistin B, 578.7 → 101.3; and IS, 748.6 → 158.4. No interference by components of blank plasma or commonly used drugs was observed. The relationship between colistin A colistin B concentrations and their corresponding peak height ratios to the IS was linear over the range of 0.05 - 10 μg/ml. Inter-day coefficient of variation and bias were, respectively, ≤11.5% and −3.0 to 6.0 for colistin A and ≤9.9 and −4.7 to 3.0 for colistin B. Mean extraction recovery of colistin A, colistin B, and the IS were 97%, 94%, and 97%, respectively. The method was applied to assess the stability of colistin A and colistin B in processed samples (24 hr. at room temperature, 48 hours at −20°C) and unprocessed samples (24 hr. at room temperature, 8 weeks at −20°C) and after three cycles of freeze and thaw found to be ≥87%.","PeriodicalId":68458,"journal":{"name":"分析质谱与色谱期刊(英文)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"分析质谱与色谱期刊(英文)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/IJAMSC.2021.91001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A simple and reliable high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the determination of colistin A and colistin B in human plasma was developed and validated. Clarithromycin was used as an internal standard (IS). Plasma extraction was performed using C-18 cartridges and methanol containing 0.1% formic acid. Analysis was performed using Atlantis dC18 (2.1 × 100 mm, 3 μm) column at room temperature and a mobile phase of 0.2% formic acid in acetonitrile and water (50:50, v:v), delivered at a flow rate of 0.2 ml/minute. Eluent was detected in the positive ion mode using electrospray ionization at the following transitions of mass to charge (m/z): colistin A, 585.6 → 101.4; colistin B, 578.7 → 101.3; and IS, 748.6 → 158.4. No interference by components of blank plasma or commonly used drugs was observed. The relationship between colistin A colistin B concentrations and their corresponding peak height ratios to the IS was linear over the range of 0.05 - 10 μg/ml. Inter-day coefficient of variation and bias were, respectively, ≤11.5% and −3.0 to 6.0 for colistin A and ≤9.9 and −4.7 to 3.0 for colistin B. Mean extraction recovery of colistin A, colistin B, and the IS were 97%, 94%, and 97%, respectively. The method was applied to assess the stability of colistin A and colistin B in processed samples (24 hr. at room temperature, 48 hours at −20°C) and unprocessed samples (24 hr. at room temperature, 8 weeks at −20°C) and after three cycles of freeze and thaw found to be ≥87%.
LC-MS/MS法测定人血浆中的粘菌素:验证和稳定性研究
建立并验证了一种简单可靠的高效液相色谱-串联质谱法(LC-MS/MS)测定人血浆中粘菌素A和粘菌素B的方法。克拉霉素被用作内标(IS)。使用C-18滤筒和含有0.1%甲酸的甲醇进行血浆提取。使用Atlantis dC18(2.1×100 mm,3μm)柱在室温下进行分析,流动相为0.2%甲酸的乙腈和水(50:50,v:v),流速为0.2 ml/分钟。在以下质荷转换(m/z)下,使用电喷雾电离以正离子模式检测洗脱液:粘菌素A,585.6→ 101.4;粘菌素B,578.7→ 101.3;和IS 748.6→ 158.4.未观察到空白血浆成分或常用药物的干扰。粘菌素A和粘菌素B的浓度及其与IS的峰高比在0.05-10μg/ml范围内呈线性关系。粘菌素A的日间变异系数和偏倚分别为≤11.5%和−3.0至6.0,粘菌素B的日内变异系数和偏差分别为≤9.9和−4.7至3.0。粘菌素A、粘菌素B和IS的平均提取回收率分别为97%、94%和97%。该方法用于评估加工样品(室温24小时,−20°C 48小时)和未加工样品(常温24小时,–20°C 8周)中粘菌素A和粘菌素B的稳定性,并在冷冻和解冻三个循环后发现其稳定性≥87%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
7
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信