Relationships Between Choroidal Characteristics and Disease Activity in Acute Central Serous Chorioretinopathy

IF 0.1 Q4 OPHTHALMOLOGY
Gye-sang Lim, Kyung Tae Kim, Eoi Jong Seo
{"title":"Relationships Between Choroidal Characteristics and Disease Activity in Acute Central Serous Chorioretinopathy","authors":"Gye-sang Lim, Kyung Tae Kim, Eoi Jong Seo","doi":"10.3341/jkos.2023.64.8.709","DOIUrl":null,"url":null,"abstract":"Purpose: To investigate choroidal characteristics during active and resolved (presence and absence of subretinal fluid, respectively) central serous chorioretinopathy (CSC), and to clarify their relationships with disease activity.Methods: The choroidal characteristics of 33 CSC and 35 age-matched control eyes were analyzed using optical coherence tomography (OCT). The CSC group included eyes with subretinal fluid at baseline. Horizontal OCT images passing through the macula, and data for age, sex, visual acuity, and refractive error, were acquired. The subretinal fluid height and subfoveal choroidal thickness were measured. The total choroidal area (TCA), luminal choroidal area (LCA), and stromal choroidal area (SCA) were measured using ImageJ software. The choroidal vascularity index (CVI) was defined as the ratio of LCA to TCA. The measurements were repeated after 5.6 months following complete absorption of the subretinal fluid. The choroidal characteristics were compared between the active and resolved phases.Results: The CSC group had significantly greater choroidal thickness, TCA, LCA, and CVI values compared to the control group. The choroidal thickness, TCA, LCA, and SCA were significantly reduced after resolution compared to active CSC. However., the decrease in SCA was greater than that in LCA, which led to a significant increase in CVI (68.6 ± 3.2 vs. 71.6 ± 3.0, p < 0.001) after CSC resolution.Conclusions: CVI measurements may allow estimation of CSC disease activity. TCA, LCA, SCA, and CVI changes may indicate whether the disease is active or resolved, and thus guide CSC treatment.","PeriodicalId":17341,"journal":{"name":"Journal of The Korean Ophthalmological Society","volume":" ","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2023.64.8.709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate choroidal characteristics during active and resolved (presence and absence of subretinal fluid, respectively) central serous chorioretinopathy (CSC), and to clarify their relationships with disease activity.Methods: The choroidal characteristics of 33 CSC and 35 age-matched control eyes were analyzed using optical coherence tomography (OCT). The CSC group included eyes with subretinal fluid at baseline. Horizontal OCT images passing through the macula, and data for age, sex, visual acuity, and refractive error, were acquired. The subretinal fluid height and subfoveal choroidal thickness were measured. The total choroidal area (TCA), luminal choroidal area (LCA), and stromal choroidal area (SCA) were measured using ImageJ software. The choroidal vascularity index (CVI) was defined as the ratio of LCA to TCA. The measurements were repeated after 5.6 months following complete absorption of the subretinal fluid. The choroidal characteristics were compared between the active and resolved phases.Results: The CSC group had significantly greater choroidal thickness, TCA, LCA, and CVI values compared to the control group. The choroidal thickness, TCA, LCA, and SCA were significantly reduced after resolution compared to active CSC. However., the decrease in SCA was greater than that in LCA, which led to a significant increase in CVI (68.6 ± 3.2 vs. 71.6 ± 3.0, p < 0.001) after CSC resolution.Conclusions: CVI measurements may allow estimation of CSC disease activity. TCA, LCA, SCA, and CVI changes may indicate whether the disease is active or resolved, and thus guide CSC treatment.
急性中枢性浆液性脉络膜视网膜病变脉络膜特征与疾病活动性的关系
目的:研究中枢性浆液性脉络膜视网膜病变(CSC)活动性和消退性(分别为视网膜下液存在和不存在)时脉络膜的特征,并阐明它们与疾病活动性的关系。方法:采用光学相干断层扫描(OCT)分析33只CSC和35只年龄匹配对照眼的脉络膜特征。CSC组包括基线时有视网膜下积液的眼睛。获得通过黄斑的水平OCT图像,以及年龄、性别、视力和屈光不正的数据。测量视网膜下液高度和中央凹下脉络膜厚度。采用ImageJ软件测量总脉络膜面积(TCA)、腔内脉络膜面积(LCA)和间质脉络膜面积(SCA)。脉络膜血管指数(CVI)定义为LCA与TCA的比值。在视网膜下液完全吸收5.6个月后重复测量。比较了活性相和溶解相的脉络膜特性。结果:CSC组脉络膜厚度、TCA、LCA、CVI值均明显高于对照组。与活性CSC相比,溶解后脉络膜厚度、TCA、LCA和SCA均显著降低。然而。SCA下降幅度大于LCA,导致CSC消退后CVI显著升高(68.6±3.2 vs. 71.6±3.0,p < 0.001)。结论:CVI测量可以估计CSC疾病的活动性。TCA、LCA、SCA和CVI的变化可以指示疾病是否活跃或已消退,从而指导CSC的治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
126
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信