{"title":"Stereopsis after bilateral implantation of Toric intraocular lenses in high myopic cataract patients with astigmatism","authors":"Wei Fan ,&nbsp;Guangbin Zhang","doi":"10.1016/j.aopr.2023.07.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To evaluate near, intermediate, distance visual acuity and stereopsis after bilateral implantation of Toric intraocular lenses (IOLs) in high myopic patients with astigmatism.</p></div><div><h3>Methods</h3><p>Bilateral Toric or non-Toric IOL implantation (n ​= ​40 eyes each) was performed on high myopic cataract eyes with astigmatism. Best-corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), residual refractive astigmatism (RRA), and near, intermediate, and distance stereoacuity were measured postoperatively at 7 days, 1 month, and 3 months.</p></div><div><h3>Results</h3><p>The three-month postoperative BCDVA, UCIVA, and UCNVA of the Toric group were 0.08 ​± ​0.07, 0.30 ​± ​0.11, and 0.23 ​± ​0.14 LogMAR. All improved over the preoperative assessments (<em>P</em> ​&lt; ​0.05). The RRA, UCIVA, and UCNVA were significantly better in the Toric group than the non-Toric group at all follow-up examinations (all <em>P</em> ​&lt; ​0.05). At 3 months, the median near and intermediate stereoacuity of the Toric group were 100 (range 40 – 400) and 120 (range 50 – 400) arcsec, which were better than the non-Toric group (both <em>P</em> ​&lt; ​0.05). Fine near stereopsis ≥100 arcsec was present in 65% of the Toric patients, and 50% had good intermediate stereopsis of ≥100 arcsec. However among non-Toric patients, only 15% and 5% achieved fine near and intermediate stereopsis. The postoperative BCDVA and best-corrected distance stereoacuity were similar in the two groups (<em>P</em> ​&gt; ​0.05).</p></div><div><h3>Conclusions</h3><p>In bilateral high myopic cataract patients with astigmatism, Toric IOLs not only improved UCIVA, UCNVA, and RRA, but also enhanced near and intermediate stereopsis acuity.</p></div>","PeriodicalId":72103,"journal":{"name":"Advances in ophthalmology practice and research","volume":"3 3","pages":"Pages 147-152"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ab/53/main.PMC10577849.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in ophthalmology practice and research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667376223000197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

To evaluate near, intermediate, distance visual acuity and stereopsis after bilateral implantation of Toric intraocular lenses (IOLs) in high myopic patients with astigmatism.

Methods

Bilateral Toric or non-Toric IOL implantation (n ​= ​40 eyes each) was performed on high myopic cataract eyes with astigmatism. Best-corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), residual refractive astigmatism (RRA), and near, intermediate, and distance stereoacuity were measured postoperatively at 7 days, 1 month, and 3 months.

Results

The three-month postoperative BCDVA, UCIVA, and UCNVA of the Toric group were 0.08 ​± ​0.07, 0.30 ​± ​0.11, and 0.23 ​± ​0.14 LogMAR. All improved over the preoperative assessments (P ​< ​0.05). The RRA, UCIVA, and UCNVA were significantly better in the Toric group than the non-Toric group at all follow-up examinations (all P ​< ​0.05). At 3 months, the median near and intermediate stereoacuity of the Toric group were 100 (range 40 – 400) and 120 (range 50 – 400) arcsec, which were better than the non-Toric group (both P ​< ​0.05). Fine near stereopsis ≥100 arcsec was present in 65% of the Toric patients, and 50% had good intermediate stereopsis of ≥100 arcsec. However among non-Toric patients, only 15% and 5% achieved fine near and intermediate stereopsis. The postoperative BCDVA and best-corrected distance stereoacuity were similar in the two groups (P ​> ​0.05).

Conclusions

In bilateral high myopic cataract patients with astigmatism, Toric IOLs not only improved UCIVA, UCNVA, and RRA, but also enhanced near and intermediate stereopsis acuity.

Abstract Image

Abstract Image

高度近视散光白内障患者双侧托里人工晶状体植入术后的立体视觉。
目的:评价高度近视散光患者双侧托里人工晶状体植入术后的近、中、远视力和立体视觉。方法:双侧托里或非托里人工晶状体植入术(n​=​每只40眼)对具有散光的高度近视性白内障眼进行。术后第7天、第1个月和第3个月分别测量最佳矫正远距视力(BCDVA)、未矫正中距视力(UCIVA)、未矫治近距视力(UCNVA)、残余屈光性散光(RRA)以及近、中、远距立体视力。结果:Toric组术后3个月BCDVA、UCIVA和UCNVA分别为0.08​±​0.070.30​±​0.11和0.23​±​0.14 LogMAR。与术前评估相比均有改善(P​P​P​P​>​结论:在伴有散光的双侧高度近视白内障患者中,Toric IOL不仅改善了UCIVA、UCNVA和RRA,而且提高了近中立体视觉的视力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
审稿时长
66 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信