Visceral adipose tissue reference data computed for GE HealthCare DXA from the National Health and Nutrition Examination Survey data set

IF 4.2 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM
Obesity Pub Date : 2023-10-05 DOI:10.1002/oby.23888
Jonathan P. Bennett, Brandon K. Quon, Bo Fan, En Liu, Leila Kazemi, Rosa C. Villegas-Valle, Raj Ahgun, Xian-pin Wu, Hou-De Zhou, Ying Lu, John A. Shepherd
{"title":"Visceral adipose tissue reference data computed for GE HealthCare DXA from the National Health and Nutrition Examination Survey data set","authors":"Jonathan P. Bennett,&nbsp;Brandon K. Quon,&nbsp;Bo Fan,&nbsp;En Liu,&nbsp;Leila Kazemi,&nbsp;Rosa C. Villegas-Valle,&nbsp;Raj Ahgun,&nbsp;Xian-pin Wu,&nbsp;Hou-De Zhou,&nbsp;Ying Lu,&nbsp;John A. Shepherd","doi":"10.1002/oby.23888","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>The National Health and Nutrition Examination Survey (NHANES) characterizes body composition representative of the US population using dual-energy x-ray absorptiometry (DXA) scans. These population-level trends of abdominal subcutaneous and visceral adipose tissue (SAT and VAT) are useful for identifying measures associated with increased disease risk. Recently, VAT and SAT data collected by Hologic DXA in NHANES were published online; however, there are known differences in the absolute calibration of DXA systems by make. The purpose of this study was to create reference tables suitable for calculating <i>z</i> scores and percentile values for GE HealthCare (GEHC) DXA systems.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>DXA scans were acquired on participants aged 8 to 59 years using Hologic systems. DXA measures were converted to GEHC and described using the least median squares curve fitting method in pediatrics (aged &lt;20 years) and adults (aged 20–59 years).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A total of 11,972 adults and 7298 pediatrics were included for this analysis. Adult and pediatric curves were generated by sex and by ethnicity (non-Hispanic White, non-Hispanic Black, Hispanic, Asian, Other) and were derived as a function of age.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>These results show the ability to generate VAT and SAT reference data for GEHC systems using Hologic DXA data representative of the US youth and adult population.</p>\n </section>\n </div>","PeriodicalId":215,"journal":{"name":"Obesity","volume":"31 12","pages":"2947-2959"},"PeriodicalIF":4.2000,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Obesity","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/oby.23888","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The National Health and Nutrition Examination Survey (NHANES) characterizes body composition representative of the US population using dual-energy x-ray absorptiometry (DXA) scans. These population-level trends of abdominal subcutaneous and visceral adipose tissue (SAT and VAT) are useful for identifying measures associated with increased disease risk. Recently, VAT and SAT data collected by Hologic DXA in NHANES were published online; however, there are known differences in the absolute calibration of DXA systems by make. The purpose of this study was to create reference tables suitable for calculating z scores and percentile values for GE HealthCare (GEHC) DXA systems.

Methods

DXA scans were acquired on participants aged 8 to 59 years using Hologic systems. DXA measures were converted to GEHC and described using the least median squares curve fitting method in pediatrics (aged <20 years) and adults (aged 20–59 years).

Results

A total of 11,972 adults and 7298 pediatrics were included for this analysis. Adult and pediatric curves were generated by sex and by ethnicity (non-Hispanic White, non-Hispanic Black, Hispanic, Asian, Other) and were derived as a function of age.

Conclusions

These results show the ability to generate VAT and SAT reference data for GEHC systems using Hologic DXA data representative of the US youth and adult population.

根据国家健康和营养检查调查数据集为GE HealthCare DXA计算的内脏脂肪组织参考数据。
目的:美国国家健康和营养检查调查(NHANES)使用双能x射线吸收仪(DXA)扫描来表征美国人群的身体组成。腹部皮下和内脏脂肪组织(SAT和VAT)的这些人群水平趋势有助于确定与疾病风险增加相关的措施。最近,Hologic DXA在NHANES收集的增值税和SAT数据在网上公布;然而,在通过制造的DXA系统的绝对校准中存在已知的差异。本研究的目的是创建适用于计算GE HealthCare(GEHC)DXA系统的z分数和百分位数的参考表。方法:对8至59岁的参与者进行DXA扫描 多年使用Hologic系统。DXA测量值转换为GEHC,并在儿科中使用最小中值平方曲线拟合方法进行描述(年龄结果:共有11972名成年人和7298名儿科被纳入该分析。成人和儿童曲线按性别和种族(非西班牙裔白人、非西班牙裔黑人、西班牙牙裔、亚裔和其他)生成,并作为年龄的函数导出。结论:这些结果表明,使用代表美国青年和成年人口的Hologic DXA数据,能够为GEHC系统生成VAT和SAT参考数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Obesity
Obesity 医学-内分泌学与代谢
CiteScore
11.70
自引率
1.40%
发文量
261
审稿时长
2-4 weeks
期刊介绍: Obesity is the official journal of The Obesity Society and is the premier source of information for increasing knowledge, fostering translational research from basic to population science, and promoting better treatment for people with obesity. Obesity publishes important peer-reviewed research and cutting-edge reviews, commentaries, and public health and medical developments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信