Morphine concentrations in distal thoracic limb synovial fluid following intravenous regional limb perfusion in horses.

IF 0.8 Q3 VETERINARY SCIENCES
Alexander Valverde, Nicola Cribb, Luis Arroyo
{"title":"Morphine concentrations in distal thoracic limb synovial fluid following intravenous regional limb perfusion in horses.","authors":"Alexander Valverde, Nicola Cribb, Luis Arroyo","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Twelve adult horses were randomly assigned to 2 groups in a prospective experimental trial. A pneumatic tourniquet (425 mmHg) was placed, under sedation, proximal to the carpus on one randomly chosen thoracic limb. A cephalic vein catheter was placed distal to the tourniquet to establish an intravenous regional limb perfusion technique (IVRLP) with morphine (0.1 mg/kg) diluted with saline 0.9% to 0.1 mL/kg, and the tourniquet left in place for 30 minutes. Horses were euthanized at 1 h (Group I) or 6 h (Group II) following the IVRLP and synovial fluid from the radiocarpal, intercarpal, metacarpophalangeal, distal interphalangeal, and digital flexor tendon sheath was obtained from the injected and contralateral (control) limb immediately after. Morphine concentrations were determined using liquid chromatography-mass spectrometry. An unpaired <i>t</i>-test was used to compare morphine concentrations from both groups (<i>P</i> < 0.05). Synovial morphine concentrations were detected in the injected limb in all horses in Group I, except in one horse in the radiocarpal joint, and detected in 5 of 6 horses in Group II. Mean synovial concentrations ranged between 301.8 ± 192.3 and 608 ± 446.6 ng/mL in Group I and between 27.0 ± 17.7 and 136.8 ± 103.6 ng/mL in Group II and were significantly higher in Group I between paired anatomical sites of both groups for the radiocarpal and distal interphalangeal joints, and the digital flexor tendon sheath. In conclusion, concentrations of morphine after IVRLP can be detected in synovial fluid distal to the tourniquet at 1 and 6 hours in horses.</p>","PeriodicalId":93919,"journal":{"name":"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire","volume":"87 4","pages":"254-259"},"PeriodicalIF":0.8000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10542951/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian journal of veterinary research = Revue canadienne de recherche veterinaire","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Twelve adult horses were randomly assigned to 2 groups in a prospective experimental trial. A pneumatic tourniquet (425 mmHg) was placed, under sedation, proximal to the carpus on one randomly chosen thoracic limb. A cephalic vein catheter was placed distal to the tourniquet to establish an intravenous regional limb perfusion technique (IVRLP) with morphine (0.1 mg/kg) diluted with saline 0.9% to 0.1 mL/kg, and the tourniquet left in place for 30 minutes. Horses were euthanized at 1 h (Group I) or 6 h (Group II) following the IVRLP and synovial fluid from the radiocarpal, intercarpal, metacarpophalangeal, distal interphalangeal, and digital flexor tendon sheath was obtained from the injected and contralateral (control) limb immediately after. Morphine concentrations were determined using liquid chromatography-mass spectrometry. An unpaired t-test was used to compare morphine concentrations from both groups (P < 0.05). Synovial morphine concentrations were detected in the injected limb in all horses in Group I, except in one horse in the radiocarpal joint, and detected in 5 of 6 horses in Group II. Mean synovial concentrations ranged between 301.8 ± 192.3 and 608 ± 446.6 ng/mL in Group I and between 27.0 ± 17.7 and 136.8 ± 103.6 ng/mL in Group II and were significantly higher in Group I between paired anatomical sites of both groups for the radiocarpal and distal interphalangeal joints, and the digital flexor tendon sheath. In conclusion, concentrations of morphine after IVRLP can be detected in synovial fluid distal to the tourniquet at 1 and 6 hours in horses.

马局部静脉灌注后远端胸肢滑液中吗啡浓度。
在一项前瞻性实验试验中,12匹成年马被随机分为2组。在镇静状态下,将气动止血带(425毫米汞柱)放置在一个随机选择的胸肢的腕骨附近。将头静脉导管放置在止血带的远端,以建立静脉局部肢体灌注技术(IVRLP),用0.9%至0.1mL/kg的生理盐水稀释吗啡(0.1mg/kg),并将止血带放置30分钟。在IVRLP后1小时(第一组)或6小时(第二组)对马实施安乐死,并在注射后立即从注射的对侧(对照)肢体获得来自桡腕、腕间、掌指、远指间和指屈肌腱鞘的滑液。使用液相色谱-质谱法测定吗啡浓度。采用非配对t检验比较两组的吗啡浓度(P<0.05)。除一匹马的桡腕关节外,第一组所有马的注射肢体中都检测到滑膜吗啡浓度,第二组6匹马中有5匹马检测到。第一组的平均滑膜浓度在301.8±192.3和608±446.6 ng/mL之间,第二组在27.0±17.7和136.8±103.6 ng/mL之间。总之,IVRLP后1小时和6小时,可以在马止血带远端的滑液中检测到吗啡浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信