{"title":"Evaluation of the risk of occupational exposure to antineoplastic drugs in healthcare sector: part I - medical gloves.","authors":"Stefano Dugheri,&nbsp;Donato Squillaci,&nbsp;Giovanni Cappelli,&nbsp;Valentina Saccomando,&nbsp;Niccolò Fanfani,&nbsp;Jacopo Ceccarelli,&nbsp;Nicola Mucci,&nbsp;Giulio Arcangeli","doi":"10.2478/aiht-2023-74-3734","DOIUrl":null,"url":null,"abstract":"<p><p>Antineoplastic drugs (ADs) are essential tools in cancer treatment, but their cytotoxicity poses a risk to workers involved in their handling. In a hospital environment fundamental strategies for minimising exposure involve proper use of safety cabinets and closed-circuit transfer devices, along with personnel training and increased awareness of risks. However, medical gloves remain the first line of defence. In this respect the evaluation of glove materials and best choices can improve hospital safety management and prevent potential hazards and long-term consequences. The aim of this study was to assess contamination of gloves in samples taken from AD administration and preparation units of nine Italian hospitals and to raise awareness of the importance of evaluating chemico-physical properties of gloves. Our findings show that 33 % of the analysed gloves were positive for at least one AD, with contaminations ranging from 0.6 to 20,729 pg/ cm<sup>2</sup>. We proposed the <i>alert glove values</i> (AGVs) for each AD as a limit value for contamination assessment and good practice evaluation. Our findings also point to multiple AD contamination (43 % of positive findings in preparation units), calculated as total AGV (AGV-T), and confirm that gloves should be replaced after 30 min of AD handling, based on cumulative permeation and area under the curve (AUC), to maintain safety and limit dermal exposure.</p>","PeriodicalId":55462,"journal":{"name":"Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology","volume":"74 3","pages":"187-197"},"PeriodicalIF":1.7000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/79/0c/aiht-74-3-aiht-2023-74-3734.PMC10549893.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/aiht-2023-74-3734","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Antineoplastic drugs (ADs) are essential tools in cancer treatment, but their cytotoxicity poses a risk to workers involved in their handling. In a hospital environment fundamental strategies for minimising exposure involve proper use of safety cabinets and closed-circuit transfer devices, along with personnel training and increased awareness of risks. However, medical gloves remain the first line of defence. In this respect the evaluation of glove materials and best choices can improve hospital safety management and prevent potential hazards and long-term consequences. The aim of this study was to assess contamination of gloves in samples taken from AD administration and preparation units of nine Italian hospitals and to raise awareness of the importance of evaluating chemico-physical properties of gloves. Our findings show that 33 % of the analysed gloves were positive for at least one AD, with contaminations ranging from 0.6 to 20,729 pg/ cm2. We proposed the alert glove values (AGVs) for each AD as a limit value for contamination assessment and good practice evaluation. Our findings also point to multiple AD contamination (43 % of positive findings in preparation units), calculated as total AGV (AGV-T), and confirm that gloves should be replaced after 30 min of AD handling, based on cumulative permeation and area under the curve (AUC), to maintain safety and limit dermal exposure.

Abstract Image

Abstract Image

Abstract Image

医疗保健部门职业接触抗肿瘤药物的风险评估:第一部分-医用手套。
抗肿瘤药物(AD)是癌症治疗的基本工具,但其细胞毒性对参与处理的工人构成风险。在医院环境中,尽量减少接触的基本策略包括正确使用安全柜和闭路转移设备,以及人员培训和提高风险意识。然而,医用手套仍然是第一道防线。在这方面,手套材料的评估和最佳选择可以改善医院的安全管理,防止潜在的危险和长期后果。本研究的目的是评估从九家意大利医院的AD管理和制备单位采集的样本中手套的污染情况,并提高人们对评估手套化学物理性能重要性的认识。我们的研究结果显示,33%的分析手套至少有一种AD呈阳性,污染范围为0.6至20729 pg/cm2。我们提出了每个AD的警报手套值(AGV)作为污染评估和良好实践评估的极限值。我们的研究结果还指出了多种AD污染(制剂中43%的阳性结果),以总AGV(AGV-T)计算,并确认根据累积渗透和曲线下面积(AUC),在AD处理30分钟后应更换手套,以保持安全并限制皮肤暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology
Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-TOXICOLOGY
CiteScore
3.50
自引率
4.80%
发文量
26
审稿时长
6-12 weeks
期刊介绍: Archives of Industrial Hygiene and Toxicology (abbr. Arh Hig Rada Toksikol) is a peer-reviewed biomedical scientific quarterly that publishes contributions relevant to all aspects of environmental and occupational health and toxicology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信