Jevin Lortie, Benjamin Rush, Grace Gage, Ravi Dhingra, Scott Hetzel, Perry J Pickhardt, Timothy P Szczykutowicz, Adam J Kuchnia
{"title":"Correcting Posterior Paraspinal Muscle Computed Tomography Density for Intravenous Contrast Material Independent of Sex and Vascular Phase.","authors":"Jevin Lortie, Benjamin Rush, Grace Gage, Ravi Dhingra, Scott Hetzel, Perry J Pickhardt, Timothy P Szczykutowicz, Adam J Kuchnia","doi":"10.1097/RTI.0000000000000743","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Intravenous contrast poses challenges to computed tomography (CT) muscle density analysis. We developed and tested corrections for contrast-enhanced CT muscle density to improve muscle analysis and the utility of CT scans for the assessment of myosteatosis.</p><p><strong>Materials and methods: </strong>Using retrospective images from 240 adults who received routine abdominal CT imaging from March to November 2020 with weight-based iodine contrast, we obtained paraspinal muscle density measurements from noncontrast (NC), arterial, and venous-phase images. We used a calibration sample to develop 9 different mean and regression-based corrections for the effect of contrast. We applied the corrections in a validation sample and conducted equivalence testing.</p><p><strong>Results: </strong>We evaluated 140 patients (mean age 52.0 y [SD: 18.3]; 60% female) in the calibration sample and 100 patients (mean age 54.8 y [SD: 18.9]; 60% female) in the validation sample. Contrast-enhanced muscle density was higher than NC by 8.6 HU (SD: 6.2) for the arterial phase (female, 10.4 HU [SD: 5.7]; male, 6.0 HU [SD:6.0]) and by 6.4 HU [SD:8.1] for the venous phase (female, 8.0 HU [SD: 8.6]; male, 4.0 HU [SD: 6.6]). Corrected contrast-enhanced and NC muscle density was equivalent within 3 HU for all correctionns. The -7.5 HU correction, independent of sex and phase, performed well for arterial (95% CI: -0.18, 1.80 HU) and venous-phase data (95% CI: -0.88, 1.41 HU).</p><p><strong>Conclusions: </strong>Our validated correction factor of -7.5 HU renders contrast-enhanced muscle density statistically similar to NC density and is a feasible rule-of-thumb for clinicians to implement.</p>","PeriodicalId":49974,"journal":{"name":"Journal of Thoracic Imaging","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2023-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10950837/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thoracic Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RTI.0000000000000743","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Intravenous contrast poses challenges to computed tomography (CT) muscle density analysis. We developed and tested corrections for contrast-enhanced CT muscle density to improve muscle analysis and the utility of CT scans for the assessment of myosteatosis.
Materials and methods: Using retrospective images from 240 adults who received routine abdominal CT imaging from March to November 2020 with weight-based iodine contrast, we obtained paraspinal muscle density measurements from noncontrast (NC), arterial, and venous-phase images. We used a calibration sample to develop 9 different mean and regression-based corrections for the effect of contrast. We applied the corrections in a validation sample and conducted equivalence testing.
Results: We evaluated 140 patients (mean age 52.0 y [SD: 18.3]; 60% female) in the calibration sample and 100 patients (mean age 54.8 y [SD: 18.9]; 60% female) in the validation sample. Contrast-enhanced muscle density was higher than NC by 8.6 HU (SD: 6.2) for the arterial phase (female, 10.4 HU [SD: 5.7]; male, 6.0 HU [SD:6.0]) and by 6.4 HU [SD:8.1] for the venous phase (female, 8.0 HU [SD: 8.6]; male, 4.0 HU [SD: 6.6]). Corrected contrast-enhanced and NC muscle density was equivalent within 3 HU for all correctionns. The -7.5 HU correction, independent of sex and phase, performed well for arterial (95% CI: -0.18, 1.80 HU) and venous-phase data (95% CI: -0.88, 1.41 HU).
Conclusions: Our validated correction factor of -7.5 HU renders contrast-enhanced muscle density statistically similar to NC density and is a feasible rule-of-thumb for clinicians to implement.
期刊介绍:
Journal of Thoracic Imaging (JTI) provides authoritative information on all aspects of the use of imaging techniques in the diagnosis of cardiac and pulmonary diseases. Original articles and analytical reviews published in this timely journal provide the very latest thinking of leading experts concerning the use of chest radiography, computed tomography, magnetic resonance imaging, positron emission tomography, ultrasound, and all other promising imaging techniques in cardiopulmonary radiology.
Official Journal of the Society of Thoracic Radiology:
Japanese Society of Thoracic Radiology
Korean Society of Thoracic Radiology
European Society of Thoracic Imaging.