{"title":"Mechanical Aortic Valve Thrombosis with Heart Failure Successfully Treated with Oral Anticoagulation: A Case Report.","authors":"Muhannad Ababneh,&nbsp;Abdullah Al-Kasasbeh,&nbsp;Emad Algorani","doi":"10.2147/VHRM.S425525","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of anticoagulation is mandatory for prevention of prosthetic valve thrombosis (PVT) worldwide, regardless of the valve type or position in the heart. In case a thrombosis causes symptomatic dysfunction, treatment usually includes the use of thrombolytic therapy or surgery. We report a case of PVT involving a patient with a mechanical aortic valve which was treated entirely with the use of anticoagulation therapy (warfarin).</p><p><strong>Case presentation: </strong>A 58-year-old man had an aortic valve replacement using a Carbomedics<sup>®</sup> mechanical valve due to severe aortic stenosis as a result of a calcific bicuspid native aortic valve. He was commenced on warfarin after surgery which was continued thereafter. He presented to our hospital after three years with shortness of breath at rest. On clinical examination, his condition was poor with a New York Heart Association functional classification of IV. He was in sinus rhythm and had an enlarged heart shadow on chest X-ray. Transesophageal echocardiography (TEE) revealed aortic valve regurgitation with vegetations on the anterior valve leaflet causing reduced hemi leaflet motility and a mean pressure gradient of 50 mmHg. Cinefluoroscopy revealed a dysfunctional mechanical valve leaflet. Surgery was at high risk of mortality due to the patient's clinical status and he was continued on warfarin therapy with close monitoring. Cinefluoroscopy and echocardiography done six months later revealed complete dissolution of thrombus and a normally functioning mechanical aortic valve.</p><p><strong>Conclusion: </strong>Only a few cases of symptomatic, thrombotic mechanical aortic valve were entirely treated with anticoagulation only. Our patient is one such case who had resolution of symptoms and improvement on NYHA functional classification (IV to I).</p>","PeriodicalId":23597,"journal":{"name":"Vascular Health and Risk Management","volume":"19 ","pages":"617-620"},"PeriodicalIF":2.6000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/79/ce/vhrm-19-617.PMC10506610.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular Health and Risk Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/VHRM.S425525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 1

Abstract

Background: The use of anticoagulation is mandatory for prevention of prosthetic valve thrombosis (PVT) worldwide, regardless of the valve type or position in the heart. In case a thrombosis causes symptomatic dysfunction, treatment usually includes the use of thrombolytic therapy or surgery. We report a case of PVT involving a patient with a mechanical aortic valve which was treated entirely with the use of anticoagulation therapy (warfarin).

Case presentation: A 58-year-old man had an aortic valve replacement using a Carbomedics® mechanical valve due to severe aortic stenosis as a result of a calcific bicuspid native aortic valve. He was commenced on warfarin after surgery which was continued thereafter. He presented to our hospital after three years with shortness of breath at rest. On clinical examination, his condition was poor with a New York Heart Association functional classification of IV. He was in sinus rhythm and had an enlarged heart shadow on chest X-ray. Transesophageal echocardiography (TEE) revealed aortic valve regurgitation with vegetations on the anterior valve leaflet causing reduced hemi leaflet motility and a mean pressure gradient of 50 mmHg. Cinefluoroscopy revealed a dysfunctional mechanical valve leaflet. Surgery was at high risk of mortality due to the patient's clinical status and he was continued on warfarin therapy with close monitoring. Cinefluoroscopy and echocardiography done six months later revealed complete dissolution of thrombus and a normally functioning mechanical aortic valve.

Conclusion: Only a few cases of symptomatic, thrombotic mechanical aortic valve were entirely treated with anticoagulation only. Our patient is one such case who had resolution of symptoms and improvement on NYHA functional classification (IV to I).

Abstract Image

Abstract Image

口服抗凝治疗心力衰竭并发机械性主动脉瓣血栓形成1例报告。
背景:在全世界范围内,无论瓣膜类型或在心脏中的位置如何,都必须使用抗凝药物来预防人工瓣膜血栓形成(PVT)。如果血栓形成导致症状性功能障碍,治疗通常包括溶栓治疗或手术。我们报告了一例PVT,涉及一名机械主动脉瓣患者,该患者完全采用抗凝治疗(华法林)。病例介绍:一名58岁的男子因钙化的双叶天然主动脉瓣导致严重主动脉狭窄,使用Carbomedics®机械瓣膜进行了主动脉瓣置换术。手术后,他开始服用华法林,此后继续服用。三年后,他因休息时呼吸急促来到我们医院。经临床检查,他的情况很差,纽约心脏协会功能分类为IV级。他处于窦性心律,胸部X光检查显示心脏阴影增大。经食管超声心动图(TEE)显示主动脉瓣反流,前瓣叶上有赘生物,导致半瓣叶运动减少,平均压力梯度为50mmHg。电影透视显示一个功能失调的机械瓣叶。由于患者的临床状况,手术的死亡率很高,他在密切监测下继续接受华法林治疗。六个月后进行的电影透视和超声心动图显示血栓完全溶解,机械主动脉瓣功能正常。结论:只有少数症状性血栓性机械性主动脉瓣患者完全采用抗凝治疗。我们的患者就是这样一个病例,其症状得到缓解,NYHA功能分类(IV至I)有所改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Vascular Health and Risk Management
Vascular Health and Risk Management PERIPHERAL VASCULAR DISEASE-
CiteScore
4.20
自引率
3.40%
发文量
109
审稿时长
16 weeks
期刊介绍: An international, peer-reviewed journal of therapeutics and risk management, focusing on concise rapid reporting of clinical studies on the processes involved in the maintenance of vascular health; the monitoring, prevention, and treatment of vascular disease and its sequelae; and the involvement of metabolic disorders, particularly diabetes. In addition, the journal will also seek to define drug usage in terms of ultimate uptake and acceptance by the patient and healthcare professional.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信