State of the Art in Radiostereometric Analysis for Tibial Baseplate Migration and Future Research Directions.

IF 1.7 4区 医学 Q4 BIOPHYSICS
Abigail E Niesen, Maury L Hull
{"title":"State of the Art in Radiostereometric Analysis for Tibial Baseplate Migration and Future Research Directions.","authors":"Abigail E Niesen, Maury L Hull","doi":"10.1115/1.4063626","DOIUrl":null,"url":null,"abstract":"<p><p>Radiostereometric analysis (RSA) measures movement (migration) of a baseplate relative to the underlying tibia after total knee arthroplasty (TKA) and has been used extensively to evaluate safety of new implant designs and/or surgical techniques regarding baseplate loosening. Because RSA is a complex methodology which involves various choices that researchers make, including whether to use marker-based or model-based methods, which migration metric to report, how to relate short-term migrations to long-term risk, and how these choices impact error, the objectives of this review were to: (1) lay out a comprehensive structure illustrating the multiple components/considerations for RSA and their interrelations, (2) review components of the structure using the latest RSA literature, and (3) use the preceding review as a context for identifying future areas of study. The components to be reviewed were structured using the following topics: type of RSA, migration metrics, sources of error, studies/reports of error, stability limits, and studies of error in stability limits. Based on the current RSA literature and knowledge gaps which exist, the following future research directions were identified: (1) revising the ISO standard to require reporting of clinical measurement error (bias) and recommending use of a local baseplate coordinate system, (2) identifying the migration metric and associated threshold most predictive of baseplate loosening for individual patients, (3) creating a method for data sharing to improve individual patient diagnostics, and (4) determining an appropriate stability limit for model-based RSA for group stability and individual patient diagnostics.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063626","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Radiostereometric analysis (RSA) measures movement (migration) of a baseplate relative to the underlying tibia after total knee arthroplasty (TKA) and has been used extensively to evaluate safety of new implant designs and/or surgical techniques regarding baseplate loosening. Because RSA is a complex methodology which involves various choices that researchers make, including whether to use marker-based or model-based methods, which migration metric to report, how to relate short-term migrations to long-term risk, and how these choices impact error, the objectives of this review were to: (1) lay out a comprehensive structure illustrating the multiple components/considerations for RSA and their interrelations, (2) review components of the structure using the latest RSA literature, and (3) use the preceding review as a context for identifying future areas of study. The components to be reviewed were structured using the following topics: type of RSA, migration metrics, sources of error, studies/reports of error, stability limits, and studies of error in stability limits. Based on the current RSA literature and knowledge gaps which exist, the following future research directions were identified: (1) revising the ISO standard to require reporting of clinical measurement error (bias) and recommending use of a local baseplate coordinate system, (2) identifying the migration metric and associated threshold most predictive of baseplate loosening for individual patients, (3) creating a method for data sharing to improve individual patient diagnostics, and (4) determining an appropriate stability limit for model-based RSA for group stability and individual patient diagnostics.

胫骨底板移位放射立体测量分析的现状和未来的研究方向。
放射立体测量分析(RSA)测量全膝关节置换术(TKA)后基板相对于下方胫骨的运动(迁移),并已被广泛用于评估新植入物设计和/或与基板松动有关的手术技术的安全性。因为RSA是一种复杂的方法,它涉及研究人员做出的各种选择,包括是使用基于标记的方法还是基于模型的方法,报告哪种迁移指标,如何将短期迁移与长期风险联系起来,以及这些选择如何影响错误,本综述的目的是:(1)制定一个全面的结构,说明RSA的多个组成部分/考虑因素及其相互关系;(2)使用最新的RSA文献综述该结构的组成部分;(3)将之前的综述作为确定未来研究领域的背景。要审查的组件使用以下主题构建:RSA类型、迁移度量、错误源、错误研究/报告、稳定性极限和稳定性极限中的错误研究。基于目前RSA文献和存在的知识空白,确定了以下未来的研究方向:(1)修订ISO标准,要求报告临床测量误差(偏差),并建议使用局部底板坐标系;(2)确定最能预测个别患者底板松动的迁移度量和相关阈值,(3)创建用于数据共享的方法以改进个体患者诊断,以及(4)确定用于组稳定性和个体患者诊断的基于模型的RSA的适当稳定性极限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信