Raul Montalvo, Eyner Castro, Janet Rojas, Carlos Camargo, Carina Ninahuanca
{"title":"Effect of the modified snorkel mask as noninvasive ventilatory support in patients with acute hypoxemic respiratory failure due to COVID-19.","authors":"Raul Montalvo, Eyner Castro, Janet Rojas, Carlos Camargo, Carina Ninahuanca","doi":"10.29390/001c.83254","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The shortage of mechanical ventilators during the COVID-19 pandemic led doctors to use alternative noninvasive ventilation systems, including a modified snorkel mask. Data on the use of the modified snorkel mask is limited.</p><p><strong>Purpose: </strong>The study aims to describe the effect and clinical characteristics of patients with COVID-19 treated with a snorkel mask and to investigate the factors associated with the failure to use noninvasive ventilation with a snorkel mask.</p><p><strong>Methods: </strong>In this retrospective observational study, adult patients with COVID-19 who were treated with a snorkel mask at Daniel Alcides Carrion Hospital of Huancayo-Perú were selected.</p><p><strong>Results: </strong>Of the 390 patients included, 158 (20.5%) received noninvasive ventilation with a snorkel, 84 (53.2%) patients were discharged alive without intubation, and the mortality rate was 22%. In the control group that received standard treatment, 129 patients (55.6%) failed (i.e., deceased or admitted to a mechanical ventilator). The mortality rate was 33.2%. ROX index < 4.8, consolidation-type tomographic pattern, and the presence of complications, such as bacterial pneumonia or thromboembolism, were independently associated with a higher risk of noninvasive ventilation failure with snorkels.</p><p><strong>Conclusions: </strong>Using the snorkel system resulted in an absolute mortality reduction of 11%, and recovery increased by 15% compared to the standard treatment system. Therefore, this device can be used as an acceptable alternative in the absence of mechanical ventilators.</p>","PeriodicalId":39373,"journal":{"name":"Canadian Journal of Respiratory Therapy","volume":"59 ","pages":"145-153"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6b/79/cjrt_2023_59_83254.PMC10540154.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Respiratory Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29390/001c.83254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"0","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The shortage of mechanical ventilators during the COVID-19 pandemic led doctors to use alternative noninvasive ventilation systems, including a modified snorkel mask. Data on the use of the modified snorkel mask is limited.
Purpose: The study aims to describe the effect and clinical characteristics of patients with COVID-19 treated with a snorkel mask and to investigate the factors associated with the failure to use noninvasive ventilation with a snorkel mask.
Methods: In this retrospective observational study, adult patients with COVID-19 who were treated with a snorkel mask at Daniel Alcides Carrion Hospital of Huancayo-Perú were selected.
Results: Of the 390 patients included, 158 (20.5%) received noninvasive ventilation with a snorkel, 84 (53.2%) patients were discharged alive without intubation, and the mortality rate was 22%. In the control group that received standard treatment, 129 patients (55.6%) failed (i.e., deceased or admitted to a mechanical ventilator). The mortality rate was 33.2%. ROX index < 4.8, consolidation-type tomographic pattern, and the presence of complications, such as bacterial pneumonia or thromboembolism, were independently associated with a higher risk of noninvasive ventilation failure with snorkels.
Conclusions: Using the snorkel system resulted in an absolute mortality reduction of 11%, and recovery increased by 15% compared to the standard treatment system. Therefore, this device can be used as an acceptable alternative in the absence of mechanical ventilators.
期刊介绍:
The CJRT is published four times a year and represents the interests of respiratory therapists nationally and internationally. The CJRT has been redesigned to act as an educational dissemination tool. The CJRT encourages submission of original articles, papers, commentaries, case studies, literature reviews and directed reading papers. Submissions can be sent to Rita Hansen.