Assessment of the accuracy of estimated free phenytoin concentrations in a mixed patient population.

IF 1.6 4区 医学 Q3 PHARMACOLOGY & PHARMACY
Niamh S Horton, Sally L Hanton, Leanne Sheppard, Katherine Birch, Carrie A Chadwick
{"title":"Assessment of the accuracy of estimated free phenytoin concentrations in a mixed patient population.","authors":"Niamh S Horton, Sally L Hanton, Leanne Sheppard, Katherine Birch, Carrie A Chadwick","doi":"10.1136/ejhpharm-2023-003878","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Phenytoin is an anti-epileptic drug that has a narrow therapeutic index, and therefore requires therapeutic drug monitoring. Only the free fraction is pharmacologically active, and in some cases, accurate determination of the free phenytoin concentration may be essential to prevent phenytoin toxicity. Although it is possible to measure free phenytoin concentration, often only the total concentration is measured, with equations used to estimate the free fraction. Several equations are quoted in the literature with no overall consensus with regard to accuracy. This study aimed to assess the correlation between total and free phenytoin in a mixed patient population, and to compare the accuracy of several different equations used to estimate the free phenytoin concentration.</p><p><strong>Methods: </strong>Fifty-one serum samples were analysed for total phenytoin, free phenytoin and albumin. The measured free phenytoin concentrations were compared against those estimated using five selected equations, identified through a literature search.</p><p><strong>Results: </strong>This study showed poor correlation between the total and measured free phenytoin concentrations, and between the estimated and measured free concentrations. The overall correlation was concentration-dependent, but a correction factor could not be applied to improve the accuracy consistently. The equations assessed showed wide variability between the estimated and measured free phenytoin concentrations, with several showing a clinically significant negative bias when compared with the measured free fraction.</p><p><strong>Discussion: </strong>This study highlights the disparity of the free phenytoin concentrations generated by the equations. Underestimation of free phenytoin concentrations using these equations may result in phenytoin toxicity, bringing into question the safety of using calculated values for patient management in place of physical measurement of free phenytoin concentration by ultra-performance liquid chromatography tandem mass spectrometry.</p>","PeriodicalId":12050,"journal":{"name":"European journal of hospital pharmacy : science and practice","volume":" ","pages":"143-148"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of hospital pharmacy : science and practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/ejhpharm-2023-003878","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Phenytoin is an anti-epileptic drug that has a narrow therapeutic index, and therefore requires therapeutic drug monitoring. Only the free fraction is pharmacologically active, and in some cases, accurate determination of the free phenytoin concentration may be essential to prevent phenytoin toxicity. Although it is possible to measure free phenytoin concentration, often only the total concentration is measured, with equations used to estimate the free fraction. Several equations are quoted in the literature with no overall consensus with regard to accuracy. This study aimed to assess the correlation between total and free phenytoin in a mixed patient population, and to compare the accuracy of several different equations used to estimate the free phenytoin concentration.

Methods: Fifty-one serum samples were analysed for total phenytoin, free phenytoin and albumin. The measured free phenytoin concentrations were compared against those estimated using five selected equations, identified through a literature search.

Results: This study showed poor correlation between the total and measured free phenytoin concentrations, and between the estimated and measured free concentrations. The overall correlation was concentration-dependent, but a correction factor could not be applied to improve the accuracy consistently. The equations assessed showed wide variability between the estimated and measured free phenytoin concentrations, with several showing a clinically significant negative bias when compared with the measured free fraction.

Discussion: This study highlights the disparity of the free phenytoin concentrations generated by the equations. Underestimation of free phenytoin concentrations using these equations may result in phenytoin toxicity, bringing into question the safety of using calculated values for patient management in place of physical measurement of free phenytoin concentration by ultra-performance liquid chromatography tandem mass spectrometry.

混合患者群体中估计的游离苯妥英钠浓度的准确性评估。
目的:苯妥英钠是一种抗癫痫药物,其治疗指标较窄,需要药物监测。只有游离组分具有药理活性,在某些情况下,准确测定游离苯妥英浓度可能对预防苯妥英毒性至关重要。尽管可以测量游离苯妥英浓度,但通常只测量总浓度,使用方程来估计游离分数。文献中引用了几个方程,但在准确性方面没有达成一致意见。本研究旨在评估混合患者群体中总酚妥英和游离酚妥英之间的相关性,并比较用于估计游离酚妥因浓度的几种不同方程的准确性。方法:对51份血清样品进行总酚妥英、游离酚妥英和白蛋白分析。将测得的游离苯妥英钠浓度与通过文献检索确定的五个选定方程估计的浓度进行比较。结果:本研究显示,总浓度和测得的游离苯妥英钠浓度之间以及估计浓度和测到的游离浓度之间的相关性较差。总体相关性是浓度依赖性的,但不能应用校正因子来始终如一地提高准确性。评估的方程显示,估计的和测量的游离苯妥英钠浓度之间存在很大的可变性,其中一些方程与测量的游离分数相比显示出临床上显著的负偏差。讨论:这项研究强调了方程产生的游离苯妥英钠浓度的差异。使用这些方程低估游离苯妥英浓度可能会导致苯妥英毒性,从而使使用计算值代替超高效液相色谱-串联质谱法物理测量游离苯妥因浓度的安全性受到质疑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
104
审稿时长
6-12 weeks
期刊介绍: European Journal of Hospital Pharmacy (EJHP) offers a high quality, peer-reviewed platform for the publication of practical and innovative research which aims to strengthen the profile and professional status of hospital pharmacists. EJHP is committed to being the leading journal on all aspects of hospital pharmacy, thereby advancing the science, practice and profession of hospital pharmacy. The journal aims to become a major source for education and inspiration to improve practice and the standard of patient care in hospitals and related institutions worldwide. EJHP is the only official journal of the European Association of Hospital Pharmacists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信