{"title":"Prophylactic Impella CP versus VA-ECMO in Patients Undergoing Complex High-Risk Indicated PCI","authors":"Deborah M.F. van den Buijs, Adriaan Wilgenhof, Paul Knaapen, Carlo Zivelonghi, Tom Meijers, Paul Vermeersch, Fatih Arslan, Niels Verouden, Alex Nap, Krischan Sjauw, Floris S. van den Brink","doi":"10.1155/2022/8167011","DOIUrl":null,"url":null,"abstract":"<div>\n <p><i>Objectives</i>. To compare two different forms of mechanical circulatory support (MCS) in patients with complex high-risk indicated PCI (CHIP): the Impella CP system and veno-arterial extracorporeal membrane oxygenation (VA-ECMO). <i>Background</i>. To prevent hemodynamic instability in CHIP, various MCS systems are available. However, comparable data on different forms of MCS are not at hand. <i>Methods</i>. In this multicenter observational study, we retrospectively evaluated all CHIP procedures with the support of an Impella CP or VA-ECMO, who were declined surgery by the heart team. Major adverse cardiac events (MACE), mortality at discharge, and 30-day mortality were evaluated. <i>Results</i>. A total of 41 patients were included, of which 27 patients were supported with Impella CP and 14 patients with VA-ECMO. Baseline characteristics were well-balanced in both groups. No significant difference in periprocedural hemodynamic instability was observed between both groups (3.7% vs. 14.3%; <i>p</i> = 0.22). The composite outcome of MACE showed no significant difference (30.7% vs. 21.4%; <i>p</i> = 0.59). Bleeding complications were higher in the Impella CP group, but showed no significant difference (22.2% vs. 7.1%; <i>p</i> = 0.22) and occurred more at the non-Impella access site. In-hospital mortality was 7.4% in the Impella CP group versus 14.3% in the VA-ECMO group and showed no significant difference (<i>p</i> = 0.48). 30-Day mortality showed no significant difference (7.4% vs. 21.4%; <i>p</i> = 0.09). <i>Conclusions</i>. In patients with CHIP, there were no significant differences in hemodynamic instability and overall MACE between VA-ECMO or Impella CP device as mechanical circulatory support. Based on this study, the choice of either VA-ECMO or Impella CP does not alter the outcome.</p>\n </div>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2022 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2022-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9663242/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2022/8167011","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives. To compare two different forms of mechanical circulatory support (MCS) in patients with complex high-risk indicated PCI (CHIP): the Impella CP system and veno-arterial extracorporeal membrane oxygenation (VA-ECMO). Background. To prevent hemodynamic instability in CHIP, various MCS systems are available. However, comparable data on different forms of MCS are not at hand. Methods. In this multicenter observational study, we retrospectively evaluated all CHIP procedures with the support of an Impella CP or VA-ECMO, who were declined surgery by the heart team. Major adverse cardiac events (MACE), mortality at discharge, and 30-day mortality were evaluated. Results. A total of 41 patients were included, of which 27 patients were supported with Impella CP and 14 patients with VA-ECMO. Baseline characteristics were well-balanced in both groups. No significant difference in periprocedural hemodynamic instability was observed between both groups (3.7% vs. 14.3%; p = 0.22). The composite outcome of MACE showed no significant difference (30.7% vs. 21.4%; p = 0.59). Bleeding complications were higher in the Impella CP group, but showed no significant difference (22.2% vs. 7.1%; p = 0.22) and occurred more at the non-Impella access site. In-hospital mortality was 7.4% in the Impella CP group versus 14.3% in the VA-ECMO group and showed no significant difference (p = 0.48). 30-Day mortality showed no significant difference (7.4% vs. 21.4%; p = 0.09). Conclusions. In patients with CHIP, there were no significant differences in hemodynamic instability and overall MACE between VA-ECMO or Impella CP device as mechanical circulatory support. Based on this study, the choice of either VA-ECMO or Impella CP does not alter the outcome.
期刊介绍:
Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including:
Acute coronary syndrome
Coronary disease
Congenital heart diseases
Myocardial infarction
Peripheral arterial disease
Valvular heart disease
Cardiac hemodynamics and physiology
Haemostasis and thrombosis