Development of a Biosensor Based on Angiotensin-Converting Enzyme II for Severe Acute Respiratory Syndrome Coronavirus 2 Detection in Human Saliva.

Frontiers in sensors Pub Date : 2022-01-01 Epub Date: 2022-07-13 DOI:10.3389/fsens.2022.917380
Geisianny Moreira, Lisseth Casso-Hartmann, Shoumen Palit Austin Datta, Delphine Dean, Eric McLamore, Diana Vanegas
{"title":"Development of a Biosensor Based on Angiotensin-Converting Enzyme II for Severe Acute Respiratory Syndrome Coronavirus 2 Detection in Human Saliva.","authors":"Geisianny Moreira, Lisseth Casso-Hartmann, Shoumen Palit Austin Datta, Delphine Dean, Eric McLamore, Diana Vanegas","doi":"10.3389/fsens.2022.917380","DOIUrl":null,"url":null,"abstract":"<p><p>Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the novel coronavirus responsible for COVID-19. Infection in humans requires angiotensin-converting enzyme II (hACE2) as the point of entry for SARS-CoV-2. PCR testing is generally definitive but expensive, although it is highly sensitive and accurate. Biosensor-based monitoring could be a low-cost, accurate, and non-invasive approach to improve testing capacity. We develop a capacitive hACE2 biosensor for intact SARS-CoV-2 detection in saliva. Laser-induced graphene (LIG) electrodes were modified with platinum nanoparticles. The quality control of LIG electrodes was performed using cyclic voltammetry. Truncated hACE2 was used as a biorecognition element and attached to the electrode surface by streptavidin-biotin coupling. Biolayer interferometry was used for qualitative interaction screening of hACE2 with UV-attenuated virions. Electrochemical impedance spectroscopy (EIS) was used for signal transduction. Truncated hACE2 binds wild-type SARS-CoV-2 and its variants with greater avidity than human coronavirus (common cold virus). The limit of detection (LoD) is estimated to be 2,960 copies/ml. The detection process usually takes less than 30 min. The strength of these features makes the hACE2 biosensor a potentially low-cost approach for screening SARS-CoV-2 in non-clinical settings with high demand for rapid testing (for example, schools and airports).</p>","PeriodicalId":93754,"journal":{"name":"Frontiers in sensors","volume":"3 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9386735/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fsens.2022.917380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the novel coronavirus responsible for COVID-19. Infection in humans requires angiotensin-converting enzyme II (hACE2) as the point of entry for SARS-CoV-2. PCR testing is generally definitive but expensive, although it is highly sensitive and accurate. Biosensor-based monitoring could be a low-cost, accurate, and non-invasive approach to improve testing capacity. We develop a capacitive hACE2 biosensor for intact SARS-CoV-2 detection in saliva. Laser-induced graphene (LIG) electrodes were modified with platinum nanoparticles. The quality control of LIG electrodes was performed using cyclic voltammetry. Truncated hACE2 was used as a biorecognition element and attached to the electrode surface by streptavidin-biotin coupling. Biolayer interferometry was used for qualitative interaction screening of hACE2 with UV-attenuated virions. Electrochemical impedance spectroscopy (EIS) was used for signal transduction. Truncated hACE2 binds wild-type SARS-CoV-2 and its variants with greater avidity than human coronavirus (common cold virus). The limit of detection (LoD) is estimated to be 2,960 copies/ml. The detection process usually takes less than 30 min. The strength of these features makes the hACE2 biosensor a potentially low-cost approach for screening SARS-CoV-2 in non-clinical settings with high demand for rapid testing (for example, schools and airports).

Abstract Image

Abstract Image

Abstract Image

开发基于血管紧张素转换酶 II 的生物传感器,用于检测人体唾液中的严重急性呼吸系统综合征冠状病毒 2。
严重急性呼吸系统综合征冠状病毒 2(SARS-CoV-2)是导致 COVID-19 的新型冠状病毒。人体感染 SARS-CoV-2 需要血管紧张素转换酶 II(hACE2)作为入口。聚合酶链式反应(PCR)检测虽然灵敏度高、准确性高,但一般是确定性的,而且价格昂贵。基于生物传感器的监测可作为一种低成本、准确且无创的方法来提高检测能力。我们开发了一种电容式 hACE2 生物传感器,用于完整检测唾液中的 SARS-CoV-2 病毒。我们用铂纳米粒子修饰了激光诱导石墨烯(LIG)电极。使用循环伏安法对石墨烯电极进行了质量控制。截短的 hACE2 被用作生物识别元件,并通过链霉亲和素-生物素偶联连接到电极表面。生物层干涉仪用于定性筛选 hACE2 与紫外线衰减病毒之间的相互作用。电化学阻抗谱(EIS)用于信号传导。截短的 hACE2 与野生型 SARS-CoV-2 及其变种的结合活性高于人类冠状病毒(普通感冒病毒)。检测限(LoD)估计为 2,960 拷贝/毫升。检测过程通常不超过 30 分钟。这些特点使 hACE2 生物传感器成为在对快速检测要求较高的非临床环境(如学校和机场)中筛查 SARS-CoV-2 的潜在低成本方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信