Influence of CT metal artifact reduction on SPECT/CT quantification of bone scintigraphy - Retrospective study for selected types of metal implants.

IF 1 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Nuklearmedizin-nuclear Medicine Pub Date : 2022-12-01 Epub Date: 2022-08-09 DOI:10.1055/a-1883-9281
Amelie Kugler, Torsten Kuwert, Philipp Ritt, Andreas Grings
{"title":"Influence of CT metal artifact reduction on SPECT/CT quantification of bone scintigraphy - Retrospective study for selected types of metal implants.","authors":"Amelie Kugler,&nbsp;Torsten Kuwert,&nbsp;Philipp Ritt,&nbsp;Andreas Grings","doi":"10.1055/a-1883-9281","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Implanted metal prostheses can cause severe artifacts in reconstructed computed tomography (CT) images. To reduce the diagnostic impact of these artifacts and improve attenuation correction in single photon emission computed tomography (SPECT), an algorithm of iterative metal artifact reduction (iMAR) for SPECT/CT systems was developed. The aims of this study were (a) to assess the difference in visual image quality by comparing CT and SPECT images reconstructed with and without iMAR and (b) to determine the influence of iMAR on quantitative <sup>99m</sup>Tc-uptake in SPECT/CT.</p><p><strong>Methods: </strong>This retrospective study includes 21 patients with implanted metal prostheses who underwent SPECT/CT bone scintigraphy. CT data were reconstructed with iMAR and without (noMAR) and were used for attenuation correction of SPECT data for xSPECT Quant and xSPECT Bone reconstruction. The effect of iMAR on image quality was evaluated by visual analysis and the effect on quantitative SPECT/CT was assessed by measuring HU values and absolute uptake values (kBq/mL) in volumes of interest (VOIs).</p><p><strong>Results: </strong>There was a significant reduction of visible metal artifacts with iMAR (p<0.01) in the CT images, but visual differences in the SPECT images were minor. The values of quantitative tracer uptake in VOIs near metal implants were lower for iMAR vs. noMAR xSPECT Quant (p<0.01). Only VOIs near metal showed significant differences in HU values, which were 14.6% lower for iMAR CT (p<0.01).</p><p><strong>Conclusion: </strong>The use of iMAR reduces metal artifacts in CT and improves the perceived image quality. Although in some cases a significant difference in the quantitative evaluation of SPECT/CT was observed, the influence of iMAR can be considered small in relation to other factors in the clinical setting.</p>","PeriodicalId":19238,"journal":{"name":"Nuklearmedizin-nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuklearmedizin-nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1883-9281","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/9 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Implanted metal prostheses can cause severe artifacts in reconstructed computed tomography (CT) images. To reduce the diagnostic impact of these artifacts and improve attenuation correction in single photon emission computed tomography (SPECT), an algorithm of iterative metal artifact reduction (iMAR) for SPECT/CT systems was developed. The aims of this study were (a) to assess the difference in visual image quality by comparing CT and SPECT images reconstructed with and without iMAR and (b) to determine the influence of iMAR on quantitative 99mTc-uptake in SPECT/CT.

Methods: This retrospective study includes 21 patients with implanted metal prostheses who underwent SPECT/CT bone scintigraphy. CT data were reconstructed with iMAR and without (noMAR) and were used for attenuation correction of SPECT data for xSPECT Quant and xSPECT Bone reconstruction. The effect of iMAR on image quality was evaluated by visual analysis and the effect on quantitative SPECT/CT was assessed by measuring HU values and absolute uptake values (kBq/mL) in volumes of interest (VOIs).

Results: There was a significant reduction of visible metal artifacts with iMAR (p<0.01) in the CT images, but visual differences in the SPECT images were minor. The values of quantitative tracer uptake in VOIs near metal implants were lower for iMAR vs. noMAR xSPECT Quant (p<0.01). Only VOIs near metal showed significant differences in HU values, which were 14.6% lower for iMAR CT (p<0.01).

Conclusion: The use of iMAR reduces metal artifacts in CT and improves the perceived image quality. Although in some cases a significant difference in the quantitative evaluation of SPECT/CT was observed, the influence of iMAR can be considered small in relation to other factors in the clinical setting.

CT金属伪影减少对骨闪烁成像SPECT/CT量化的影响-对选定类型金属植入物的回顾性研究。
目的:植入式金属假体在重建的计算机断层扫描(CT)图像中会产生严重的伪影。为了降低这些伪影的诊断影响并提高单光子发射计算机断层扫描(SPECT)的衰减校正,提出了一种用于SPECT/CT系统的迭代金属伪影降低(iMAR)算法。本研究的目的是(a)通过比较使用和不使用iMAR重建的CT和SPECT图像来评估视觉图像质量的差异;(b)确定iMAR对SPECT/CT定量99mtc摄取的影响。方法:回顾性研究21例金属假体植入后行SPECT/CT骨显像检查的患者。用iMAR和不使用(noMAR)重建CT数据,并用于xSPECT定量和xSPECT骨重建的SPECT数据衰减校正。通过视觉分析评估iMAR对图像质量的影响,通过测量感兴趣体积(VOIs)的HU值和绝对摄取值(kBq/mL)来评估iMAR对定量SPECT/CT的影响。结果:iMAR明显减少了可见的金属伪影(p结论:iMAR的使用减少了CT中的金属伪影,提高了感知图像质量。虽然在某些病例中观察到SPECT/CT定量评估的显著差异,但与临床环境中的其他因素相比,iMAR的影响可以被认为是很小的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
13.30%
发文量
267
审稿时长
>12 weeks
期刊介绍: Als Standes- und Fachorgan (Organ von Deutscher Gesellschaft für Nuklearmedizin (DGN), Österreichischer Gesellschaft für Nuklearmedizin und Molekulare Bildgebung (ÖGN), Schweizerischer Gesellschaft für Nuklearmedizin (SGNM, SSNM)) von hohem wissenschaftlichen Anspruch befasst sich die CME-zertifizierte Nuklearmedizin/ NuclearMedicine mit Diagnostik und Therapie in der Nuklearmedizin und dem Strahlenschutz: Originalien, Übersichtsarbeiten, Referate und Kongressberichte stellen aktuelle Themen der Diagnose und Therapie dar. Ausführliche Berichte aus den DGN-Arbeitskreisen, Nachrichten aus Forschung und Industrie sowie Beschreibungen innovativer technischer Geräte, Einrichtungen und Systeme runden das Konzept ab. Die Abstracts der Jahrestagungen dreier europäischer Fachgesellschaften sind Bestandteil der Kongressausgaben. Nuklearmedizin erscheint regelmäßig mit sechs Ausgaben pro Jahr und richtet sich vor allem an Nuklearmediziner, Radiologen, Strahlentherapeuten, Medizinphysiker und Radiopharmazeuten.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信