Surface-Active Ionic Liquid-Assisted Cloud Point Extraction for Pre-Concentration and Determination of Cobalt Ions in Pharmaceutical Preparations.

Iranian Journal of Pharmaceutical Research : IJPR Pub Date : 2022-05-17 eCollection Date: 2022-12-01 DOI:10.5812/ijpr-127043
Farzad Bamdad, Zahra Habibi
{"title":"Surface-Active Ionic Liquid-Assisted Cloud Point Extraction for Pre-Concentration and Determination of Cobalt Ions in Pharmaceutical Preparations.","authors":"Farzad Bamdad,&nbsp;Zahra Habibi","doi":"10.5812/ijpr-127043","DOIUrl":null,"url":null,"abstract":"<p><p>Herein we describe an efficient, simple, and precise micelle-mediated microextraction strategy based on the aggregation behavior of surface-active ionic liquids (SAILs) for the preconcentration and determination of cobalt ions in pharmaceutical preparations. Unlike the commonly used hydrophobic ionic liquids in IL-based microextraction methods, a water-soluble surface-active ionic liquid [1-hexadecyl 3-methylimidazolium chloride (C<sub>16</sub>MeImCl)] was used. A modified cloud point extraction (CPE) procedure based on the C<sub>16</sub>MeImCl-Triton X-114 mixed micellar system was proposed as an efficient extracting phase. A comparison of the analytical features of the extraction process with and without SAILs revealed the benefits of the proposed method. Advantages such as a wider linear range, lower detection limit, higher reproducibility, and improved extraction efficiency highlighted the proposed method over the conventional CPE method. These attractive specifications are due to the higher extraction efficiencies achieved in the presence of the SAIL and its favorable effects at the phase separation stage. Various parameters affecting the extraction efficiency were optimized by univariate and multivariate (Box-Behnken design) approaches. The calibration curve was obtained in the optimal experimental conditions with a linear range from 0.01 to 5.5 mg L<sup>-1</sup> of cobalt ion concentration (R = 0.9992) and a detection limit of about 0.005 mg L<sup>-1</sup>. The RSD% for 10 replicate determinations of 1.0 mg L<sup>-1</sup> Co was 0.9%. The proposed method was successfully applied to determine cobalt ions in vitamin B<sub>12</sub> ampoules and tablets.</p>","PeriodicalId":416671,"journal":{"name":"Iranian Journal of Pharmaceutical Research : IJPR","volume":" ","pages":"e127043"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/18/c6/ijpr-21-1-127043.PMC9347226.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pharmaceutical Research : IJPR","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5812/ijpr-127043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/12/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Herein we describe an efficient, simple, and precise micelle-mediated microextraction strategy based on the aggregation behavior of surface-active ionic liquids (SAILs) for the preconcentration and determination of cobalt ions in pharmaceutical preparations. Unlike the commonly used hydrophobic ionic liquids in IL-based microextraction methods, a water-soluble surface-active ionic liquid [1-hexadecyl 3-methylimidazolium chloride (C16MeImCl)] was used. A modified cloud point extraction (CPE) procedure based on the C16MeImCl-Triton X-114 mixed micellar system was proposed as an efficient extracting phase. A comparison of the analytical features of the extraction process with and without SAILs revealed the benefits of the proposed method. Advantages such as a wider linear range, lower detection limit, higher reproducibility, and improved extraction efficiency highlighted the proposed method over the conventional CPE method. These attractive specifications are due to the higher extraction efficiencies achieved in the presence of the SAIL and its favorable effects at the phase separation stage. Various parameters affecting the extraction efficiency were optimized by univariate and multivariate (Box-Behnken design) approaches. The calibration curve was obtained in the optimal experimental conditions with a linear range from 0.01 to 5.5 mg L-1 of cobalt ion concentration (R = 0.9992) and a detection limit of about 0.005 mg L-1. The RSD% for 10 replicate determinations of 1.0 mg L-1 Co was 0.9%. The proposed method was successfully applied to determine cobalt ions in vitamin B12 ampoules and tablets.

Abstract Image

Abstract Image

Abstract Image

表面活性离子液体辅助云点萃取法预富集和测定药物制剂中钴离子。
本文描述了一种基于表面活性离子液体(SAILs)聚集行为的高效、简单、精确的胶束介导微萃取策略,用于药物制剂中钴离子的富集和测定。与基于il的微萃取方法中常用的疏水离子液体不同,我们使用了一种水溶性表面活性离子液体[1-十六烷基3-甲基咪唑氯(C16MeImCl)]。提出了一种基于C16MeImCl-Triton X-114混合胶束体系的改进云点萃取(CPE)方法。比较了有和没有风帆的提取过程的分析特征,揭示了所提出方法的优点。与传统的CPE方法相比,该方法具有线性范围宽、检出限低、重现性好、提取效率高等优点。这些有吸引力的规格是由于在SAIL存在下获得了更高的萃取效率及其在相分离阶段的有利作用。采用单变量和多变量(Box-Behnken设计)方法对影响提取效率的各参数进行优化。在最佳实验条件下,得到了钴离子浓度在0.01 ~ 5.5 mg L-1范围内呈线性关系(R = 0.9992),检出限约为0.005 mg L-1的校准曲线。1.0 mg L-1 Co 10次重复测定的RSD%为0.9%。该方法成功地应用于维生素B12安瓿和片剂中钴离子的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书