In vitro evaluation of how the presence of the stent retriever and microcatheter influences aspiration parameters in thrombectomy according to their position inside the aspiration catheter.

IF 1.7 4区 医学 Q3 Medicine
Interventional Neuroradiology Pub Date : 2024-08-01 Epub Date: 2022-11-08 DOI:10.1177/15910199221135040
Gianmarco Bernava, Olivier Brina, Philippe Reymond, Andrea Rosi, Jeremy Hofmeister, Hasan Yilmaz, Michel Muster, Zsolt Kulcsar, Karl-Olof Lovblad, Paolo Machi
{"title":"<i>In vitro</i> evaluation of how the presence of the stent retriever and microcatheter influences aspiration parameters in thrombectomy according to their position inside the aspiration catheter.","authors":"Gianmarco Bernava, Olivier Brina, Philippe Reymond, Andrea Rosi, Jeremy Hofmeister, Hasan Yilmaz, Michel Muster, Zsolt Kulcsar, Karl-Olof Lovblad, Paolo Machi","doi":"10.1177/15910199221135040","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Several variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter.</p><p><strong>Methods: </strong>Two experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter.</p><p><strong>Results: </strong>The transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters.</p><p><strong>Conclusions: </strong>In our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11528783/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199221135040","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Several variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter.

Methods: Two experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter.

Results: The transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters.

Conclusions: In our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level.

根据支架和微导管在抽吸导管内的位置,对它们如何影响血栓切除术中的抽吸参数进行体外评估。
背景:使用支架取栓器和抽吸导管联合血栓切除术治疗急性缺血性脑卒中的方法有多种。我们的研究旨在评估微导管和支架取栓器的存在如何影响基本抽吸参数,即流速和抽吸力,这取决于它们在抽吸导管中的位置:方法:设计了两个实验装置,以评估根据支架牵引器和微导管在抽吸导管中的位置对流速和抽吸力的影响:支架截留器和微导管从远端位置过渡到近端位置会导致流速逐渐增加,但对抽吸力没有影响。此外,支架截留器的大小对流速变化没有显著影响,流速的降低与微导管直径有关。抽吸导管内部产生的负压影响了其位于不透射线标记物以外的远端部分,从而导致其部分塌陷。因此,在所有测试的抽吸导管中,测量到的抽吸力都低于理论抽吸力水平:结论:在我们的实验模型中,吸液导管内支架牵引器和微导管的位置会影响流速,但不会影响吸力。抽吸导管内产生的负压似乎决定了远端部分的塌陷,导致有效抽吸力低于理论抽吸力水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信