Evaluation of exposure factors of dual-energy contrast-enhanced mammography to optimize radiation dose with improved image quality.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Acta radiologica open Pub Date : 2022-08-11 eCollection Date: 2022-08-01 DOI:10.1177/20584601221117251
Sachila Niroshani, Tokiko Nakamura, Nikaidou Michiru, Toru Negishi
{"title":"Evaluation of exposure factors of dual-energy contrast-enhanced mammography to optimize radiation dose with improved image quality.","authors":"Sachila Niroshani,&nbsp;Tokiko Nakamura,&nbsp;Nikaidou Michiru,&nbsp;Toru Negishi","doi":"10.1177/20584601221117251","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dual-energy contrast-enhanced mammography (DECEM) is an advanced breast imaging technique of digital mammography.</p><p><strong>Purpose: </strong>To assess the total radiation dose received from complete DECEM using different combinations of exposure parameters for low- and high-energy images.</p><p><strong>Materials and methods: </strong>A dedicated phantom with three different concentrations of iodine inserts was used. Each iodine insert was 10 mm in diameter and concentration of 1.0 mgI/cm<sup>3</sup>, 2.0 mgI/cm<sup>3</sup>, and 4.0 mgI/cm<sup>3</sup>. The phantom was exposed at varying kVp levels. Mean glandular dose (MGD) was estimated. Contrast to noise ratio (CNR) and figure of merit (FOM) of the iodine inserts were used to assess the image quality.</p><p><strong>Results: </strong>The optimum CNR of the recombined images was obtained by using 28 kVp + 49 kVp tube voltage combination for 50 mm thickness, 50% fibroglandular phantom only with a 26% dose increase compared to the highest voltages (32 kVp + 49 kVp) that can be used for low energy (LE) and high energy (HE) imaging. The CNR value was increased with increasing iodine concentration (<i>R</i> <sup><i>2</i></sup> > 0.99).</p><p><strong>Conclusion: </strong>The use of as low as possible tube voltage for the LE imaging of standard 50% fibroglandular-50% adipose, 50 mm thickness breast while using the highest tube voltage for HE imaging has reduced the MGD while keeping optimum image quality.</p>","PeriodicalId":72063,"journal":{"name":"Acta radiologica open","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2022-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/de/6a/10.1177_20584601221117251.PMC9379970.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20584601221117251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Dual-energy contrast-enhanced mammography (DECEM) is an advanced breast imaging technique of digital mammography.

Purpose: To assess the total radiation dose received from complete DECEM using different combinations of exposure parameters for low- and high-energy images.

Materials and methods: A dedicated phantom with three different concentrations of iodine inserts was used. Each iodine insert was 10 mm in diameter and concentration of 1.0 mgI/cm3, 2.0 mgI/cm3, and 4.0 mgI/cm3. The phantom was exposed at varying kVp levels. Mean glandular dose (MGD) was estimated. Contrast to noise ratio (CNR) and figure of merit (FOM) of the iodine inserts were used to assess the image quality.

Results: The optimum CNR of the recombined images was obtained by using 28 kVp + 49 kVp tube voltage combination for 50 mm thickness, 50% fibroglandular phantom only with a 26% dose increase compared to the highest voltages (32 kVp + 49 kVp) that can be used for low energy (LE) and high energy (HE) imaging. The CNR value was increased with increasing iodine concentration (R 2 > 0.99).

Conclusion: The use of as low as possible tube voltage for the LE imaging of standard 50% fibroglandular-50% adipose, 50 mm thickness breast while using the highest tube voltage for HE imaging has reduced the MGD while keeping optimum image quality.

Abstract Image

Abstract Image

Abstract Image

评价双能增强乳房x线造影的暴露因素以优化辐射剂量和改善图像质量。
背景:双能量对比增强乳房x线摄影(DECEM)是一种先进的数字乳房x线摄影技术。目的:利用低能和高能图像的不同暴露参数组合,评估完全DECEM所接受的总辐射剂量。材料和方法:使用三种不同浓度碘插入物的专用假体。每个碘片直径为10 mm,浓度分别为1.0 mgI/cm3、2.0 mgI/cm3和4.0 mgI/cm3。幻影暴露在不同的kVp水平下。估计平均腺剂量(MGD)。采用对比噪声比(CNR)和优值比(FOM)对图像质量进行评价。结果:采用28 kVp + 49 kVp的管电压组合,厚度为50 mm,纤维腺影50%,与可用于低能(LE)和高能(HE)成像的最高电压(32 kVp + 49 kVp)相比,剂量仅增加26%,获得了重组图像的最佳CNR。CNR值随碘浓度的增加而增加(r2 > 0.99)。结论:采用尽可能低的管电压对标准的50%纤维腺体-50%脂肪,50 mm厚度乳房进行LE成像,而采用最高管电压进行HE成像,在保持最佳图像质量的同时降低了MGD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信