Mastoid Growth and the Configuration of Cochlear Implant Electrode Lead.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2025-05-01 Epub Date: 2022-07-21 DOI:10.1177/01455613221106221
Salman F Alhabib, Fida Almuhawas, Abdulrahman Hagr, Farid Alzhrani, Nezar Hamed, Saad Alenzi, Yassin Abdelsamad, Anandhan Dhanasingh
{"title":"Mastoid Growth and the Configuration of Cochlear Implant Electrode Lead.","authors":"Salman F Alhabib, Fida Almuhawas, Abdulrahman Hagr, Farid Alzhrani, Nezar Hamed, Saad Alenzi, Yassin Abdelsamad, Anandhan Dhanasingh","doi":"10.1177/01455613221106221","DOIUrl":null,"url":null,"abstract":"<p><p>ObjectivesTo study the changes in the coiled configuration of electrode excess lead in the mastoid cavity in the cochlear implant recipients over time.MethodsPost-operative CT scans at two different appointments of fourteen patients with cochlear implants (CI) were retrospectively analyzed using a DICOM viewer software (3D-slicer). Mastoid thickness (MT) was measured in the oblique coronal plane from the round window (RW) entrance to the mastoid edge and inter-cochlear distance (ICD) was measured in the axial plane at the fundus level between two ears. 3D segmentation of the entire inner ear of both sides and coiled electrode excess lead was performed to visually compare the changes in coiled configuration between the two CT scan time points.ResultMT and ICD increased logarithmically with the patient's age, as has been measured from both the 1st and the 2nd CT scans and a weak linear correlation between MT and ICD was observed. Growth in MT and ICT measured between the time of 1st and 2nd CT scans showed a strong linear correlation. In eight cases, changes in the electrode excess lead have been observed in the 2nd CT scan, either a change in the coiling configuration of electrode excess lead or shifted laterally toward the mastoid edge. The ICD growth between the 1st and the 2nd CT scans was >2 mm in only seven cases and all of them were children. All other six cases had no observed changes in the coiled electrode lead. In addition, the mastoid growth between the 1st and the 2nd CT scan was >2.5 mm in only 4 cases.ConclusionCoiled configuration of electrode excess lead could change when the MT and ICD increased over time.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":" ","pages":"NP321-NP327"},"PeriodicalIF":16.4000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/01455613221106221","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

ObjectivesTo study the changes in the coiled configuration of electrode excess lead in the mastoid cavity in the cochlear implant recipients over time.MethodsPost-operative CT scans at two different appointments of fourteen patients with cochlear implants (CI) were retrospectively analyzed using a DICOM viewer software (3D-slicer). Mastoid thickness (MT) was measured in the oblique coronal plane from the round window (RW) entrance to the mastoid edge and inter-cochlear distance (ICD) was measured in the axial plane at the fundus level between two ears. 3D segmentation of the entire inner ear of both sides and coiled electrode excess lead was performed to visually compare the changes in coiled configuration between the two CT scan time points.ResultMT and ICD increased logarithmically with the patient's age, as has been measured from both the 1st and the 2nd CT scans and a weak linear correlation between MT and ICD was observed. Growth in MT and ICT measured between the time of 1st and 2nd CT scans showed a strong linear correlation. In eight cases, changes in the electrode excess lead have been observed in the 2nd CT scan, either a change in the coiling configuration of electrode excess lead or shifted laterally toward the mastoid edge. The ICD growth between the 1st and the 2nd CT scans was >2 mm in only seven cases and all of them were children. All other six cases had no observed changes in the coiled electrode lead. In addition, the mastoid growth between the 1st and the 2nd CT scan was >2.5 mm in only 4 cases.ConclusionCoiled configuration of electrode excess lead could change when the MT and ICD increased over time.

乳突生长与人工耳蜗电极导线的配置
目的研究人工耳蜗植入者乳突腔内多余导线电极盘绕结构随时间的变化:方法:使用 DICOM 查看器软件(3D-slicer)回顾性分析了 14 名人工耳蜗(CI)植入者在两次不同时间的术后 CT 扫描结果。乳突厚度(MT)是在从圆窗(RW)入口到乳突边缘的斜冠状面上测量的,耳蜗间距离(ICD)是在两耳之间耳底水平的轴向面上测量的。对两侧整个内耳和盘绕电极多余导线进行三维分割,以直观比较两个 CT 扫描时间点之间盘绕配置的变化:结果:根据第一次和第二次 CT 扫描的测量结果,MT 和 ICD 随患者年龄的增长呈对数增长,并且 MT 和 ICD 之间呈弱线性相关。在第 1 次和第 2 次 CT 扫描之间测量的 MT 和 ICT 的增长显示出很强的线性相关性。在 8 个病例中,第 2 次 CT 扫描观察到电极多余导线发生变化,要么是电极多余导线的卷绕结构发生变化,要么是向乳突边缘侧移。只有 7 个病例在第一次和第二次 CT 扫描之间的 ICD 增长大于 2 毫米,且均为儿童。其他六个病例的盘绕电极导线均未观察到变化。此外,只有 4 个病例在第一次和第二次 CT 扫描之间的乳突增生大于 2.5 毫米:结论:当 MT 和 ICD 随时间增长时,多余电极导线的盘绕结构可能会发生变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信