Enrico Giacomin, Pasquale Valerio Falzone, Pietro Bernardo Dall'Aglio, Raimondo Pittorru, Manuel De Lazzari, Riccardo Vianello, Emanuele Bertaglia, Vincenzo Tarzia, Sabino Iliceto, Gino Gerosa, Federico Migliore
{"title":"Subcutaneous implantable cardioverter defibrillator after transvenous lead extraction: safety, efficacy and outcome.","authors":"Enrico Giacomin, Pasquale Valerio Falzone, Pietro Bernardo Dall'Aglio, Raimondo Pittorru, Manuel De Lazzari, Riccardo Vianello, Emanuele Bertaglia, Vincenzo Tarzia, Sabino Iliceto, Gino Gerosa, Federico Migliore","doi":"10.1007/s10840-022-01293-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Subcutaneous implantable cardioverter defibrillator (S-ICD) is a suitable alternative for transvenous ICD (TV-ICD) patients who have undergone transvenous lead extraction (TLE). Limited data are available on the outcome of S-ICD patients implanted after TLE. We assessed the safety, efficacy, and outcome of S-ICD implantation after TLE of TV-ICD.</p><p><strong>Methods: </strong>The study population consisted of 36 consecutive patients with a median age of 52 (44-66) years who underwent S-ICD implantation after TLE of TV-ICD.</p><p><strong>Results: </strong>Indications for TLE were infection (63.9%) and lead malfunction (36.1%). During a median follow-up of 31 months, 3 patients (8.3%) experienced appropriate therapy and 7 patients (19.4%) experienced complications including inappropriate therapy (n = 4; 11.1%), isolated pocket erosion (n = 2; 5.5%), and ineffective therapy (n = 1; 2.8%). No lead/hardware dysfunction was reported. Premature device explantation occurred in 4 patients (11%). Eight patients (22.2%) died during follow-up, six of them (75%) because of refractory heart failure (HF). There were no S-ICD-related deaths. Predictors of mortality included NYHA class ≥ 2 (HR 5.05; 95% CI 1.00-26.38; p = 0.04), hypertension (HR 22.72; 95% CI 1.05-26.31; p = 0.02), diabetes (HR 10.64; 95% CI 2.05-55.60; p = 0.001) and ischemic heart disease (HR 5.92; 95% CI 1.17-30.30; p = 0.01).</p><p><strong>Conclusion: </strong>Our study provides evidences on the use of S-ICD as an alternative after TV-ICD explantation for both infection and lead failure. Mortality of S-ICD patients who underwent TV-ICD explantation does not appear to be correlated with the presence of a prior infection, S-ICD therapy (appropriate or inappropriate), or S-ICD complications but rather to worsening of HF or other comorbidities.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"1399-1407"},"PeriodicalIF":4.7000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12436517/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10840-022-01293-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Subcutaneous implantable cardioverter defibrillator (S-ICD) is a suitable alternative for transvenous ICD (TV-ICD) patients who have undergone transvenous lead extraction (TLE). Limited data are available on the outcome of S-ICD patients implanted after TLE. We assessed the safety, efficacy, and outcome of S-ICD implantation after TLE of TV-ICD.
Methods: The study population consisted of 36 consecutive patients with a median age of 52 (44-66) years who underwent S-ICD implantation after TLE of TV-ICD.
Results: Indications for TLE were infection (63.9%) and lead malfunction (36.1%). During a median follow-up of 31 months, 3 patients (8.3%) experienced appropriate therapy and 7 patients (19.4%) experienced complications including inappropriate therapy (n = 4; 11.1%), isolated pocket erosion (n = 2; 5.5%), and ineffective therapy (n = 1; 2.8%). No lead/hardware dysfunction was reported. Premature device explantation occurred in 4 patients (11%). Eight patients (22.2%) died during follow-up, six of them (75%) because of refractory heart failure (HF). There were no S-ICD-related deaths. Predictors of mortality included NYHA class ≥ 2 (HR 5.05; 95% CI 1.00-26.38; p = 0.04), hypertension (HR 22.72; 95% CI 1.05-26.31; p = 0.02), diabetes (HR 10.64; 95% CI 2.05-55.60; p = 0.001) and ischemic heart disease (HR 5.92; 95% CI 1.17-30.30; p = 0.01).
Conclusion: Our study provides evidences on the use of S-ICD as an alternative after TV-ICD explantation for both infection and lead failure. Mortality of S-ICD patients who underwent TV-ICD explantation does not appear to be correlated with the presence of a prior infection, S-ICD therapy (appropriate or inappropriate), or S-ICD complications but rather to worsening of HF or other comorbidities.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.