R J Valero Mamani, J Penchyna Grub, G Blanco Rodríguez, G Teyssier Morales, M Peña García
{"title":"Endoscopic management of recurrent tracheoesophageal fistula with trichloroacetic acid in pediatric patients.","authors":"R J Valero Mamani, J Penchyna Grub, G Blanco Rodríguez, G Teyssier Morales, M Peña García","doi":"10.54847/cp.2022.03.13","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Surgical repair of recurrent tracheoesophageal fistula has a high risk of complications. Therefore, various endoscopic techniques have been used to avoid complications.</p><p><strong>Objective: </strong>To understand the usefulness of trichloroacetic acid endoscopic application for the treatment of recurrent tracheoesophageal fistula.</p><p><strong>Materials and methods: </strong>An observational, descriptive, retrospective, case-series-based study was carried out in a tertiary pediatric hospital. Records of patients with recurrent tracheoesophageal fistula from 2015 to 2021 were reviewed. All patients within this period underwent brushing and trichloroacetic acid application.</p><p><strong>Results: </strong>Mean time of recurrent tracheoesophageal fistula occurrence was 4.8 months (range: 1-19.2). Two patients had a small fistula (less than 4 mm), three patients had a medium fistula (4 mm), and two patients had a large fistula (more than 4 mm). Mean sessions for fistula closure were 2.2 (range: 1-4). Mean time between procedures was 22 days (range: 14-30). Mean follow-up since fistula closure confirmation was 33 months (range: 9-72), during which no recurrences were noted.</p><p><strong>Conclusion: </strong>Endoscopic management of recurrent transesophageal fistula with trichloroacetic acid is a safe and effective procedure. Brushing and trichloroacetic acid combined improve success rates. Fistulas over 4 mm in diameter require more procedures. However, a larger patient cohort and a longer follow-up period are needed to confirm this.</p>","PeriodicalId":10316,"journal":{"name":"Cirugia pediatrica : organo oficial de la Sociedad Espanola de Cirugia Pediatrica","volume":"35 3","pages":"113-117"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cirugia pediatrica : organo oficial de la Sociedad Espanola de Cirugia Pediatrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54847/cp.2022.03.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3
Abstract
Introduction: Surgical repair of recurrent tracheoesophageal fistula has a high risk of complications. Therefore, various endoscopic techniques have been used to avoid complications.
Objective: To understand the usefulness of trichloroacetic acid endoscopic application for the treatment of recurrent tracheoesophageal fistula.
Materials and methods: An observational, descriptive, retrospective, case-series-based study was carried out in a tertiary pediatric hospital. Records of patients with recurrent tracheoesophageal fistula from 2015 to 2021 were reviewed. All patients within this period underwent brushing and trichloroacetic acid application.
Results: Mean time of recurrent tracheoesophageal fistula occurrence was 4.8 months (range: 1-19.2). Two patients had a small fistula (less than 4 mm), three patients had a medium fistula (4 mm), and two patients had a large fistula (more than 4 mm). Mean sessions for fistula closure were 2.2 (range: 1-4). Mean time between procedures was 22 days (range: 14-30). Mean follow-up since fistula closure confirmation was 33 months (range: 9-72), during which no recurrences were noted.
Conclusion: Endoscopic management of recurrent transesophageal fistula with trichloroacetic acid is a safe and effective procedure. Brushing and trichloroacetic acid combined improve success rates. Fistulas over 4 mm in diameter require more procedures. However, a larger patient cohort and a longer follow-up period are needed to confirm this.