Analysis and fabrication of a small-scale radio-frequency balun for magnetic resonance imaging amplifier.

Yingliang Li, Shouhua Luo, Chunyi Liu, Yuanyuan Ye
{"title":"Analysis and fabrication of a small-scale radio-frequency balun for magnetic resonance imaging amplifier.","authors":"Yingliang Li,&nbsp;Shouhua Luo,&nbsp;Chunyi Liu,&nbsp;Yuanyuan Ye","doi":"10.1063/5.0095045","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, the authors report the design and fabrication of a small mixed-integrated balun for magnetic resonance imaging (MRI). The device was designed by using the positive anti-symmetric coupling method, which applies the lump surface-mount technology capacitors as well as mirror-symmetric coupling strips that were etched on the top and bottom layers of a printed circuit board. The capacitors reduced the length of the coupling strips and compensated for imbalances in the phase and gain due to errors in the fabrication process. The structure and equivalent even-odd circuit model of the device was modeled and examined using commercial software to optimize the design parameters. Following this, the device was fabricated and its performance was assessed through measurements using a network analyzer. The results showed that imbalances in the gain and phase were lower than 0.1 dB and 1°, respectively, and the insertion loss and the input voltage standing-wave ratio (VSWR) were lower than 0.4 dB and -25 dB, respectively. More importantly, the device was small, with dimensions of 50 × 60 × 1.5 mm. This makes it suitable for MRI applications involving highly integrated miniaturized systems. The proposed device was integrated into a 3.0 T radio-frequency power amplifier (RFPA) and reduced the dimensions of its power modules by 20% compared with the traditional balun. Finally, the RFPA module was used in an 3.0T MRI system for imaging experiments, and the results showed that the balun can help obtain high-quality scanning images.</p>","PeriodicalId":519534,"journal":{"name":"The Review of scientific instruments","volume":" ","pages":"114711"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Review of scientific instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0095045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this study, the authors report the design and fabrication of a small mixed-integrated balun for magnetic resonance imaging (MRI). The device was designed by using the positive anti-symmetric coupling method, which applies the lump surface-mount technology capacitors as well as mirror-symmetric coupling strips that were etched on the top and bottom layers of a printed circuit board. The capacitors reduced the length of the coupling strips and compensated for imbalances in the phase and gain due to errors in the fabrication process. The structure and equivalent even-odd circuit model of the device was modeled and examined using commercial software to optimize the design parameters. Following this, the device was fabricated and its performance was assessed through measurements using a network analyzer. The results showed that imbalances in the gain and phase were lower than 0.1 dB and 1°, respectively, and the insertion loss and the input voltage standing-wave ratio (VSWR) were lower than 0.4 dB and -25 dB, respectively. More importantly, the device was small, with dimensions of 50 × 60 × 1.5 mm. This makes it suitable for MRI applications involving highly integrated miniaturized systems. The proposed device was integrated into a 3.0 T radio-frequency power amplifier (RFPA) and reduced the dimensions of its power modules by 20% compared with the traditional balun. Finally, the RFPA module was used in an 3.0T MRI system for imaging experiments, and the results showed that the balun can help obtain high-quality scanning images.

磁共振成像放大器用小型射频平衡器的分析与制造。
在这项研究中,作者报告了一种用于磁共振成像(MRI)的小型混合集成平衡的设计和制造。该器件采用正反对称耦合方法设计,该方法采用块状表面贴装技术电容器和镜面对称耦合条,在印刷电路板的顶层和底层蚀刻。电容器减少了耦合带的长度,并补偿了由于制造过程中的误差而导致的相位和增益的不平衡。利用商业软件对器件的结构和等效奇偶电路模型进行建模和校核,优化设计参数。在此之后,该装置被制造出来,并通过使用网络分析仪进行测量来评估其性能。结果表明,增益和相位不平衡分别小于0.1 dB和1°,插入损耗和输入驻波比(VSWR)分别小于0.4 dB和-25 dB。更重要的是,该装置体积小,尺寸为50 × 60 × 1.5 mm。这使得它适用于涉及高度集成的小型化系统的MRI应用。该器件集成在3.0 T射频功率放大器(RFPA)中,与传统的平衡器相比,其功率模块的尺寸减小了20%。最后,将RFPA模块应用于3.0T MRI系统中进行成像实验,结果表明,该平衡器可以帮助获得高质量的扫描图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书