Toward the fabrication of a 5-μm-resolution Wolter microscope for the National Ignition Facility (invited).

Patrick R Champey, Jeffery Kolodziejczak, Bernard Kozioziemski, Jacqueline Davis, Charles Griffith, Tom Kester, Kiranmayee Kilaru, Amy Meekham, Joe Menapace, Brian Ramsey, Oliver J Roberts, Javier Sanchez, Panini Singam, W Scott Smith, Chet Speegle, Mark Stahl, Tayyab Suratwala, Nick Thomas, Mark Young, Julia K Vogel
{"title":"Toward the fabrication of a 5-μm-resolution Wolter microscope for the National Ignition Facility (invited).","authors":"Patrick R Champey,&nbsp;Jeffery Kolodziejczak,&nbsp;Bernard Kozioziemski,&nbsp;Jacqueline Davis,&nbsp;Charles Griffith,&nbsp;Tom Kester,&nbsp;Kiranmayee Kilaru,&nbsp;Amy Meekham,&nbsp;Joe Menapace,&nbsp;Brian Ramsey,&nbsp;Oliver J Roberts,&nbsp;Javier Sanchez,&nbsp;Panini Singam,&nbsp;W Scott Smith,&nbsp;Chet Speegle,&nbsp;Mark Stahl,&nbsp;Tayyab Suratwala,&nbsp;Nick Thomas,&nbsp;Mark Young,&nbsp;Julia K Vogel","doi":"10.1063/5.0101304","DOIUrl":null,"url":null,"abstract":"<p><p>Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. We present the fabrication and test of a nickel-cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics<sup>®</sup> model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.</p>","PeriodicalId":519534,"journal":{"name":"The Review of scientific instruments","volume":" ","pages":"113504"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Review of scientific instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0101304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. We present the fabrication and test of a nickel-cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

国家点火装置用5 μm分辨率Wolter显微镜的研制(特邀)。
计算机控制的抛光、计量和复制技术的进步导致了x射线反射镜的制造工艺,能够生产高分辨率的沃尔特显微镜。我们提出了镍钴复制全壳x射线反射镜的制造和测试,该反射镜由精细的图形和抛光芯棒电铸而成。该芯棒设计用于8米源-探测器距离显微镜,放大倍数为10倍,并进行了优化,以减少壳端20 mm内发生的壳变形。这与改进的复制工具设计和由详细的COMSOL Multiphysics®模型提供的精炼浴池参数相结合,减少了镜子中的复制错误。通过实施计算机控制的抛光过程,改进了芯轴表面加工,纠正了低频芯轴形状误差,并实现了
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书