Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study.

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Advanced Prosthodontics Pub Date : 2022-10-01 Epub Date: 2022-10-28 DOI:10.4047/jap.2022.14.5.294
Reham Osman, Nawal Alharbi
{"title":"Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An <i>in-vitro</i> study.","authors":"Reham Osman,&nbsp;Nawal Alharbi","doi":"10.4047/jap.2022.14.5.294","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches.</p><p><strong>Materials and methods: </strong>Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights-Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3Shape™, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05.</p><p><strong>Results: </strong>The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (<i>P</i> =.959 and <i>P</i> =.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III.</p><p><strong>Conclusion: </strong>The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f7/3b/jap-14-294.PMC9672697.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2022.14.5.294","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches.

Materials and methods: Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights-Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3Shape™, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05.

Results: The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P =.959 and P =.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III.

Conclusion: The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

Abstract Image

Abstract Image

Abstract Image

腭穹窿形态对全无牙弓的口腔内扫描时间和准确性有影响吗?一项体外研究。
目的:研究不同腭弓形态对全无牙弓口腔内扫描(IO)精度和扫描速度的影响。材料和方法:使用CAD软件(Meshmixer)对具有不同腭顶高度的全无牙颌弓进行了三种不同的虚拟模型-Cl I中度(u型),Cl II深(陡峭)和Cl III浅(平坦)的数字设计。Autodesk, USA)和3d打印使用基于sla的3d打印机(XFAB;DWS,意大利)(n = 30;每组10个标本)。每个模型使用口内扫描仪(Trios 3;3形状™、丹麦)。记录所有样品的扫描时间。使用Geomagic Control X v2020 (Geomagic;3 dsystems,美国)。采用单因素方差分析(ANOVA)检验检测各组扫描时间、正确率和精密度的差异。统计学意义设为α = 0.05。结果:二类组不能完成扫描过程,需修改厂家推荐的扫描技术。方差分析显示,各试验组的正确率和精密度值差异无统计学意义(P =。959, P =。658年,分别)。深腭穹窿(clii)的扫描时间明显长于cli和III。结论:腭深穹窿等复杂病例扫描方案的选择至关重要。与其他两组相比,深拱顶病例采用改进的长路径扫描方案导致扫描时间增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信