Development of a new quantification method using partial volume effect correction for individual energy peaks in 111In-pentetreotide SPECT/CT.

Q3 Medicine
Kosuke Yamashita, Noriaki Miyaji, Kazuki Motegi, Takashi Terauchi, Shigeki Ito
{"title":"Development of a new quantification method using partial volume effect correction for individual energy peaks in <sup>111</sup>In-pentetreotide SPECT/CT.","authors":"Kosuke Yamashita,&nbsp;Noriaki Miyaji,&nbsp;Kazuki Motegi,&nbsp;Takashi Terauchi,&nbsp;Shigeki Ito","doi":"10.22038/AOJNMB.2022.61394.1430","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Somatostatin receptor scintigraphy (SRS) using <sup>111</sup>In-pentetreotide has no established quantification method. The purpose of this study was to develop a new quantitative method to correct the partial volume effect (PVE) for individual energy peaks in <sup>111</sup>In-pentetreotide single-photon emission computed tomography (SPECT).</p><p><strong>Methods: </strong>Phantom experiments were performed to construct a new quantitative method. In the phantom experiments, a NEMA IEC body phantom was used. Acquisition was performed using two energy peaks (171 keV and 245 keV) on the SPECT/CT system. The volume of interest was set at each hot sphere and lung insert in the SPECT images of each energy peak, and the recovery coefficient (RC) was calculated to understand the PVE. A new quantitative index, the indium uptake index (IUI), was calculated using the RC to correct the PVE. The quantitative accuracy of the IUI in the hot sphere was confirmed. Case studies were performed to clarify the quantitative accuracy. In a case study, the relationship between the IUI and the Krenning score, which is used as a visual assessment, was evaluated for each lesion.</p><p><strong>Results: </strong>The obtained RCs showed that the energy peak at 171 keV was faster in recovering the effect of PVE than that at 245 keV. The IUI in the 17-mm-diameter hot sphere was overestimated by 4.8% and 8.3% at 171 keV and 245 keV, respectively, compared to the actual IUIs. The relationship between IUI and Krenning score was rs=0.773 (<i>p</i><0.005) at sum, rs=0.739 (<i>p</i><0.005) at 171 keV, and rs=0.773 (<i>p</i><0.005) at 245 keV.</p><p><strong>Conclusion: </strong>We have developed a new quantification method for <sup>111</sup>In-pentetreotide SPECT/CT using RC-based PVE correction for an individual energy peak of 171 keV. The quantitative accuracy of this method was high even for accumulations of less than 20 mm, and it showed a good relationship with the Krenning score; therefore, the clinical usefulness of IUI was demonstrated.</p>","PeriodicalId":8503,"journal":{"name":"Asia Oceania Journal of Nuclear Medicine and Biology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205847/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia Oceania Journal of Nuclear Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/AOJNMB.2022.61394.1430","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Somatostatin receptor scintigraphy (SRS) using 111In-pentetreotide has no established quantification method. The purpose of this study was to develop a new quantitative method to correct the partial volume effect (PVE) for individual energy peaks in 111In-pentetreotide single-photon emission computed tomography (SPECT).

Methods: Phantom experiments were performed to construct a new quantitative method. In the phantom experiments, a NEMA IEC body phantom was used. Acquisition was performed using two energy peaks (171 keV and 245 keV) on the SPECT/CT system. The volume of interest was set at each hot sphere and lung insert in the SPECT images of each energy peak, and the recovery coefficient (RC) was calculated to understand the PVE. A new quantitative index, the indium uptake index (IUI), was calculated using the RC to correct the PVE. The quantitative accuracy of the IUI in the hot sphere was confirmed. Case studies were performed to clarify the quantitative accuracy. In a case study, the relationship between the IUI and the Krenning score, which is used as a visual assessment, was evaluated for each lesion.

Results: The obtained RCs showed that the energy peak at 171 keV was faster in recovering the effect of PVE than that at 245 keV. The IUI in the 17-mm-diameter hot sphere was overestimated by 4.8% and 8.3% at 171 keV and 245 keV, respectively, compared to the actual IUIs. The relationship between IUI and Krenning score was rs=0.773 (p<0.005) at sum, rs=0.739 (p<0.005) at 171 keV, and rs=0.773 (p<0.005) at 245 keV.

Conclusion: We have developed a new quantification method for 111In-pentetreotide SPECT/CT using RC-based PVE correction for an individual energy peak of 171 keV. The quantitative accuracy of this method was high even for accumulations of less than 20 mm, and it showed a good relationship with the Krenning score; therefore, the clinical usefulness of IUI was demonstrated.

Abstract Image

Abstract Image

Abstract Image

建立了一种新的定量方法,使用部分体积效应校正111in - pentreotide SPECT/CT中单个能量峰。
目的:用111in -戊替肽进行生长抑素受体显像(SRS)检测尚无确定的定量方法。本研究的目的是建立一种新的定量方法来校正111in - pentreotide单光子发射计算机断层扫描(SPECT)中单个能量峰的部分体积效应(PVE)。方法:采用幻像实验建立新的定量方法。体模实验采用NEMA - IEC体模。在SPECT/CT系统上使用两个能量峰(171 keV和245 keV)进行采集。在每个能量峰的SPECT图像中,在每个热球和肺插入处设置感兴趣的体积,并计算恢复系数(RC)来了解PVE。利用RC对PVE进行修正,计算了铟吸收指数(IUI)。证实了热球中IUI的定量准确性。进行了案例研究,以澄清定量的准确性。在一个案例研究中,IUI与Krenning评分之间的关系被用作视觉评估,用于评估每个病变。结果:得到的RCs表明,171 keV的能量峰比245 keV的能量峰更快地恢复了PVE的作用。与实际IUI相比,直径为171kev和245kev的17 mm热球IUI分别高估了4.8%和8.3%。IUI与Krenning评分的关系为rs=0.773 (ppp)。结论:我们建立了一种新的定量方法,采用基于rc的PVE校正,对单个能量峰171 keV进行定量。对于小于20 mm的堆积,该方法的定量精度较高,且与克伦宁分数呈良好的相关关系;因此,IUI的临床应用得到了证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asia Oceania Journal of Nuclear Medicine and Biology
Asia Oceania Journal of Nuclear Medicine and Biology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.80
自引率
0.00%
发文量
28
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信