The Efficacy of Divabirth Vaginal Dilator to Prevent Pelvic Floor Trauma During Labor: A Protocol Study.

IF 1.1 Q3 SURGERY
International Journal of Surgery Protocols Pub Date : 2022-10-28 eCollection Date: 2022-01-01 DOI:10.29337/ijsp.179
Muhammad Nurhadi Rahman, Siswanto Agus Wilopo, Ova Emilia
{"title":"The Efficacy of Divabirth Vaginal Dilator to Prevent Pelvic Floor Trauma During Labor: A Protocol Study.","authors":"Muhammad Nurhadi Rahman,&nbsp;Siswanto Agus Wilopo,&nbsp;Ova Emilia","doi":"10.29337/ijsp.179","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Vaginal birth may have a negative impact on nerve structure and function, pelvic floor muscle structure, and function. Reducing the risk of pelvic floor injuries during vaginal birth is one of the most effective ways to prevent labor morbidity in women. There is a lack of tools developed based on this approach, especially in Indonesia. Therefore, we aimed to know the efficacy of a vaginal dilator called Divabirth based on labor outcomes.</p><p><strong>Methods: </strong>This clinical study involved subjects who are randomly grouped in to the control and treatment groups. Subjects in the treatment group are told to utilize vaginal dilator devices for 20 minutes each session, a maximum of two sessions per day, lasting 5 minutes every cycle, from 35 weeks of gestation until delivery.</p><p><strong>Discussions: </strong>The current research contributes valuable information to developing a vaginal dilator intervention program for pregnant women to reduce perineal laceration and improve labor outcomes. It may also help to lower their medical and treatment expenditures. We expect its success to be a step forward in improving reproductive health status.</p><p><strong>Highlights: </strong>Vaginal birth may have negative impact on nerve and pelvic floor muscle structure and functionLack of tool has been developed to reduce the risk of pelvic floor injuries during vaginal birthA study protocol of vaginal dilator usage to know the efficacy based on labor outcomes.</p>","PeriodicalId":42077,"journal":{"name":"International Journal of Surgery Protocols","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9635326/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Surgery Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29337/ijsp.179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Vaginal birth may have a negative impact on nerve structure and function, pelvic floor muscle structure, and function. Reducing the risk of pelvic floor injuries during vaginal birth is one of the most effective ways to prevent labor morbidity in women. There is a lack of tools developed based on this approach, especially in Indonesia. Therefore, we aimed to know the efficacy of a vaginal dilator called Divabirth based on labor outcomes.

Methods: This clinical study involved subjects who are randomly grouped in to the control and treatment groups. Subjects in the treatment group are told to utilize vaginal dilator devices for 20 minutes each session, a maximum of two sessions per day, lasting 5 minutes every cycle, from 35 weeks of gestation until delivery.

Discussions: The current research contributes valuable information to developing a vaginal dilator intervention program for pregnant women to reduce perineal laceration and improve labor outcomes. It may also help to lower their medical and treatment expenditures. We expect its success to be a step forward in improving reproductive health status.

Highlights: Vaginal birth may have negative impact on nerve and pelvic floor muscle structure and functionLack of tool has been developed to reduce the risk of pelvic floor injuries during vaginal birthA study protocol of vaginal dilator usage to know the efficacy based on labor outcomes.

Abstract Image

分娩阴道扩张器预防分娩时盆底损伤的疗效:一项方案研究。
背景:阴道分娩可能对神经结构和功能、盆底肌肉结构和功能产生负面影响。减少阴道分娩时骨盆底损伤的风险是预防分娩并发症最有效的方法之一。缺乏基于这种方法开发的工具,特别是在印度尼西亚。因此,我们的目的是了解阴道扩张器的功效,称为分娩的基础上的结果。方法:本临床研究随机分为对照组和治疗组。治疗组受试者被告知每次使用阴道扩张器20分钟,每天最多两次,每个周期持续5分钟,从妊娠35周到分娩。讨论:目前的研究为孕妇制定阴道扩张器干预方案提供了有价值的信息,以减少会阴撕裂和改善分娩结局。这也可能有助于降低他们的医疗和治疗费用。我们期望它的成功是在改善生殖健康状况方面向前迈出的一步。重点:阴道分娩可能对神经和骨盆底肌肉的结构和功能产生负面影响,目前还缺乏降低阴道分娩时骨盆底损伤风险的工具。阴道扩张器的使用研究方案,以了解基于分娩结果的疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
12
期刊介绍: IJS Protocols is the first peer-reviewed, international, open access journal seeking to publish research protocols across across the full breadth of the surgical field. We are aim to provide rapid submission to decision times whilst maintaining a high quality peer-review process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信