Comparative Analysis of SARS-CoV-2 Detection Kits.

Q2 Medicine
Naida Mulahuseinovic, Lana Salihefendic, Selma Durgut, Enis Kandic, Rijad Konjhodzic
{"title":"Comparative Analysis of SARS-CoV-2 Detection Kits.","authors":"Naida Mulahuseinovic,&nbsp;Lana Salihefendic,&nbsp;Selma Durgut,&nbsp;Enis Kandic,&nbsp;Rijad Konjhodzic","doi":"10.5455/aim.2022.30.110-114","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>SARS-CoV-2 is a coronavirus that causes a respiratory disease, COVID-19. For COVID-19 testing, real-time PCR is considered gold standard and therefore many commercial SARS-Cov-2 detection kits are available.</p><p><strong>Objective: </strong>The aim of the study is to determine diagnostic values of 10 different commercially available SARS-CoV-2 detection kits, based on their Ct value.</p><p><strong>Methods: </strong>For this study thirty clinical nasopharyngeal samples were collected in ALEA Genetic Center. Twenty four of them were positive, while six were negative and used as a negative control. Positive samples were selected based on the day when first symptoms appeared. RNA was extracted using the same extraction method for all samples. For amplification and comparison of detection kits, the same RT- PCR instrument was used.</p><p><strong>Results: </strong>Accuracy, sensitivity, specificity and Cohen's kappa coefficient were estimated to evaluate diagnostic values of the tested kits. This study showed that all kits showed 100% specificity. Accuracy, sensitivity and kappa coefficient varied among examined assays. Based on clinical features, LabGun<sup>TM</sup> COVID-19 Assay by LabGenomics proved to be the most sensitive, the most accurate and most specific. Therefore this assay was used as a reference kit.</p><p><strong>Conclusion: </strong>If things from practice are taken into account, accuracy and reliability of the tested commercial kits can vary compared to those obtained in this study where results were based on ideal functioning of the kits. When choosing the convenient commercial SARS-CoV-2 detection kit using RT-PCR method, many parameters need to be considered.</p>","PeriodicalId":7074,"journal":{"name":"Acta Informatica Medica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/60/3f/AIM-30-110.PMC9233452.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Informatica Medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/aim.2022.30.110-114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Background: SARS-CoV-2 is a coronavirus that causes a respiratory disease, COVID-19. For COVID-19 testing, real-time PCR is considered gold standard and therefore many commercial SARS-Cov-2 detection kits are available.

Objective: The aim of the study is to determine diagnostic values of 10 different commercially available SARS-CoV-2 detection kits, based on their Ct value.

Methods: For this study thirty clinical nasopharyngeal samples were collected in ALEA Genetic Center. Twenty four of them were positive, while six were negative and used as a negative control. Positive samples were selected based on the day when first symptoms appeared. RNA was extracted using the same extraction method for all samples. For amplification and comparison of detection kits, the same RT- PCR instrument was used.

Results: Accuracy, sensitivity, specificity and Cohen's kappa coefficient were estimated to evaluate diagnostic values of the tested kits. This study showed that all kits showed 100% specificity. Accuracy, sensitivity and kappa coefficient varied among examined assays. Based on clinical features, LabGunTM COVID-19 Assay by LabGenomics proved to be the most sensitive, the most accurate and most specific. Therefore this assay was used as a reference kit.

Conclusion: If things from practice are taken into account, accuracy and reliability of the tested commercial kits can vary compared to those obtained in this study where results were based on ideal functioning of the kits. When choosing the convenient commercial SARS-CoV-2 detection kit using RT-PCR method, many parameters need to be considered.

Abstract Image

Abstract Image

SARS-CoV-2检测试剂盒对比分析
背景:SARS-CoV-2是一种引起呼吸道疾病COVID-19的冠状病毒。对于COVID-19检测,实时PCR被认为是金标准,因此有许多商用SARS-Cov-2检测试剂盒。目的:本研究的目的是根据10种不同的市售SARS-CoV-2检测试剂盒的Ct值确定其诊断价值。方法:本研究在ALEA遗传中心收集30例临床鼻咽标本。其中24人呈阳性,6人呈阴性,作为阴性对照。根据首次出现症状的日期选择阳性样本。所有样品采用相同的提取方法提取RNA。为扩增和比较检测试剂盒,使用相同的RT- PCR仪。结果:通过准确性、敏感性、特异性和Cohen’s kappa系数评价试剂盒的诊断价值。本研究表明,所有试剂盒均具有100%的特异性。准确度、灵敏度和kappa系数在不同的检测方法中有所不同。基于临床特征,LabGenomics的LabGunTM COVID-19检测被证明是最敏感、最准确和最特异性的。因此,本试验被用作参考试剂盒。结论:如果考虑到实践中的事情,与本研究中获得的结果基于试剂盒的理想功能相比,经测试的商业试剂盒的准确性和可靠性可能会有所不同。在选择便捷的商用RT-PCR法SARS-CoV-2检测试剂盒时,需要考虑许多参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Informatica Medica
Acta Informatica Medica Medicine-Medicine (all)
CiteScore
2.90
自引率
0.00%
发文量
37
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信